background image

4

   

If the house has aluminum wiring, follow the procedure 

below:

1. 

 Connect a section of solid copper wire to the pigtail 

leads.

2. 

 Connect the aluminum wiring to the added section  

of copper wire using special connectors and/or tools 

designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer’s  

recommended procedure. Aluminum/copper connection 

must conform with local codes and industry-accepted  

wiring practices.

INSTALLATION 

INSTRUCTIONS

Prepare Built-In Oven

1. 

 Decide on the final location for the oven. Locate existing  

wiring to avoid drilling into or severing wiring during  

installation.

2. 

 To avoid floor damage, set the oven onto cardboard prior  

to installation. Do not use handle or any portion of the front 

frame for lifting.
On models with shipping feet attached:
To avoid product damage, do not remove the shipping feet 

at the front lower corners of the oven. The shipping feet will 

protect the lower oven trim until the oven is inserted into 

cabinet.

3. 

 Remove the shipping materials and tape from the oven.

4. 

 Remove the hardware package from inside the bag  

containing literature.

5. 

 Remove and set aside racks and other parts from inside  

the oven.

6. 

 Move the oven and cardboard close to the oven’s final  

location.

Electrical Requirements

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrical installer determine that 

the ground path and wire gauge are in accordance with local 

codes.
Check with a qualified electrical installer if you are not sure the 

oven is properly grounded.
This oven must be connected to a grounded metal, permanent 

wiring system.
Be sure that the electrical connection and wire size are 

adequate and in conformance with the National Electrical Code, 

ANSI/NFPA 70 – latest edition or CSA Standards C22.1-94, 

Canadian Electrical Code, Part 1 and C22.2 No. O-M91 – latest 

edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:

National Fire Protection Association  

1 Batterymarch Park 

Quincy, MA 02169-7471

CSA International 

8501 East Pleasant Valley Road 

Cleveland, OH 44131-5575

Electrical Connection

To properly install your oven, you must determine the type 

of electrical connection you will be using and follow the 

instructions provided for it here.

   

Oven must be connected to the proper electrical voltage 

and frequency as specified on the model/serial number 

rating plate. The model/serial number rating plate is located 

on the right mounting rail. See the following illustration.

Single oven 

A. Model/serial/rating plate

   

Models rated from 7.3 to 9.6 kW at 240 volts (5.5 to  

7.2 kW at 208 volts) require a separate 40-amp circuit. 

Models rated at 7.2 kW and below at 240 volts (5.4 kW  

and below at 208 volts) require a separate 30-amp circuit.

   

A time-delay fuse or circuit breaker is recommended.

   

Connect directly to the fused disconnect (or circuit breaker 

box) through flexible, armored, or nonmetallic sheathed, 

copper cable (with grounding wire). See “Make Electrical 

Connection” section.

   

Flexible cable from the oven should be connected directly 

to the junction box.

 

Fuse both sides of the line.

   

Do not cut the conduit. The length of conduit provided  

is for serviceability of the oven.

   

A UL-listed or CSA-approved conduit connector must  

be provided.

Double oven 

A. Model/serial/rating plate

A

A

WARNING

Excessive Weight Hazard

Use two or more people to move and install oven.
Failure to do so can result in back or other injury.

Remove Oven Door(s)

IMPORTANT:

 Use both hands to remove oven doors.

1. 

 Open the oven door.

2. 

 Locate the oven door latches in both corners of the oven 

door, and rotate the latches forward to the unlocked  

position.

A

B

A.  Oven door latch in locked 

position

A.  Oven door latch in unlocked 

position

Содержание KOSC504ESS

Страница 1: ... Complete Installation 7 Remove Oven Trim if necessary 7 SÉCURITÉ DU FOUR ENCASTRÉ 8 EXIGENCES D INSTALLATION 8 Outillage et pièces 8 Exigences d emplacement 8 Spécifications électriques 10 INSTRUCTIONS D INSTALLATION 11 Préparation du four encastré 11 Retirer le s porte s du four s 11 Raccordement électrique 11 Installation du four 12 Achever l installation 14 Dépose des garnitures du four au bes...

Страница 2: ...ll cabinet A 1 2 5 cm minimum diameter hole should have been drilled in right rear or the left rear corner of the support surface to pass the appliance cable through to the junction box NOTE For undercounter installation it is recommended that the junction box be located in the adjacent right or left cabinet If you are installing the junction box on rear wall behind oven the junction box must be r...

Страница 3: ... 60 3 cm overall width D 23 58 4 cm max recessed depth E 49 2 125 7 cm recessed height Cabinet Dimensions Double Oven Double Oven Installed in Cabinet A 24 61 cm min cabinet width B 1 2 5 cm top of cutout to bottom of upper cabinet door C 14 4 37 5 cm bottom of cutout to floor D 225 8 57 5 cm cutout width E 1 2 3 8 cm min bottom of cutout to top of cabinet door F 49 4 126 4 cm min cutout height Ca...

Страница 4: ...est edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No O M91 latest edition and all local codes and ordinances A copy of the above code standards can be obtained from National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 Electrical Connection To properly install your oven yo...

Страница 5: ...3 cm 3 Wire Cable from Home Power Supply 4 Wire Cable from Home Power Supply IMPORTANT Use the 4 wire cable from home power supply in the U S where local codes do not allow grounding through neutral New Branch circuit installations 1996 NEC mobile homes and recreational vehicles new construction and in Canada A Cable from home power supply B Black wires C Red wires D 4 wire flexible cable from ove...

Страница 6: ...d conduit connector 1 Connect the 2 black wires C together using a UL listed wire connector 2 Connect the 2 white wires D and the green or bare ground wire of the oven cable using a UL listed wire connector 3 Connect the 2 red wires G together using a UL listed wire connector 4 Install junction box cover B C D E F H G A I NOTE Remove side and vent trims taped to oven before installing 1 Using 2 or...

Страница 7: ...free to open and close If it is not repeat the removal and installation procedures See Remove Oven Trim section 14 Repeat for lower oven door 15 Reconnect power 16 Display panel will light briefly and PF should appear in the display 17 If display panel does not light please reference the Assistance or Service section of the Use and Care Guide or contact the dealer from whom you purchased your oven...

Страница 8: ...MARQUE Pour l installation sous un plan de travail on recommande que le boîtier de connexion soit situé dans le placard adjacent à droite ou à gauche Dans le cas de l installation du boîtier de connexion sur le mur arrière derrière le four le boîtier de connexion doit être encastré et placé dans l angle inférieur ou supérieur du placard à gauche ou à droite sinon le four ne pourra pas passer dans ...

Страница 9: ...ur l ouverture découpée E 27 4 70 5 cm min de hauteur d encastrement A B C D E A B C D E Four simple installé dans un placard A 24 61 cm min de largeur de placard B 1 2 5 cm entre le sommet de l encastrement et le bas de la porte du placard supérieur C 32 81 3 cm du fond de l encastrement au plancher D 225 8 57 5 cm de largeur pour l ouverture découpée E 1 2 3 8 cm min du fond de l encastrement au...

Страница 10: ... obtenir un exemplaire des normes des codes ci dessus contacter National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 Raccordement électrique Pour installer le four correctement il faut établir le type de raccords électriques que l on utilisera et suivre les instructions indiquées ici Le four doit être...

Страница 11: ...acement final du four Raccordement électrique Le câblage d alimentation de ce four comporte un conducteur neutre blanc et un conducteur vert ou nu de liaison à la terre connecté à la caisse ces deux conducteurs sont torsadés 1 Déconnecter la source de courant électrique 2 Faire passer le conduit de câble flexible depuis le four à travers l ouverture dans le placard 3 Le cas échéant enlever le couv...

Страница 12: ... fils homologation UL 6 Installer le couvercle du boîtier de connexion A D F H B C E G I Installation du four Câble à 3 conducteurs depuis le point de distribution du domicile É U seulement IMPORTANT Utiliser le câble à 3 conducteurs depuis le point de distribution du domicile lorsque les codes locaux autorisent un tel raccordement A Câble de l alimentation électrique du domicile B Boîtier de conn...

Страница 13: ...érieure A A Appuyer pour la mise en place de la pièce de garniture et réinstaller la vis 8 Utiliser des vis pour fixer chaque pièce de garniture sur le four 9 Réinstaller les grilles du four 10 Réinstaller la porte du four insérer les extrémités des charnières dans les ouvertures destinées à les recevoir sur le châssis du four 11 Enfoncer les charnières aussi loin qu elles peuvent aller et ouvrir ...

Страница 14: ...es vérifier qu il y a émission de chaleur Si aucune chaleur n est ressentie ou si F suivi d un nombre apparaît sur l affichage éteindre le four et contacter un technicien qualifié 5 Appuyer sur CANCEL annulation Vérification du fonctionnement du four double 1 Mettre l appareil sous tension PF devrait apparaître dans l afficheur 2 Appuyer sur UPPER OVEN four supérieur ou LOWER OVEN four inférieur p...

Страница 15: ...15 ...

Страница 16: ...W10758285A 02 2015 Printed in U S A Imprimé aux États Unis TM 2015 Used under license in Canada All rights reserved TM 2015 Utilisé sous licence au Canada Tous droits réservés ...

Отзывы: