5-1
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Refer to page 4-4 for the procedure for servic-
ing the door switches.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect the wires from the switch ter-
minals.
COMPONENT TESTING
DOOR SWITCHES
Normally-Open
Normally-Closed
Before testing a component, be sure to ob-
serve the following conditions:
• Discharge the high voltage capacitor before
conducting any of the following tests.
• All operational checks using microwave en-
ergy must be done with the microwave oven
loaded with a minimum of 275 ml (9.3 oz.) of
water in a microwave safe container.
• Conduct a microwave energy test after per-
forming any tests or repairs to the micro-
wave.
• Check that all wire leads are in the correct
position before operating the microwave
oven.
• Grasp wire connectors when removing the
wire leads from microwave parts.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
terminals of the
primary
or
secondary
interlock switch (normally-open). The
meter should indicate an open circuit (in-
finite).
5.
Touch the ohmmeter test leads to the
terminals of the
monitor
switch (normally-
closed). The meter should indicate a closed
circuit (0
Ω
).
NOTE: Pressing the actuator button should
result in opposite readings (normally-open
should read closed, and normally-closed should
read open).