INSTALLATION REQUIREMENTS

The microwave oven is set for recirculation installation. For external (wall or roof) venting, see “Venting Design Specifications” section.

Tools and Parts

Tools Needed

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools 
listed here.  

Materials needed

Standard fittings for wall or roof venting. See “Venting Design 
Specifications” section.

Parts Supplied

For information on reordering, see “Replacement Parts” section.
NOTE: The hardware items listed here are for wood studs. For 
other types of wall structures, be sure to use appropriate 
fasteners.

NOTE: Depending on model, aluminum grease filter and charcoal 
filter may be combined.

Location Requirements

Check the opening where the microwave oven will be installed. 
The location must provide:

Minimum installation dimensions. See “Installation 
Dimensions” illustration.

Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and 
minimum 3/8" (10 mm) thickness drywall or plaster/lath within 
cabinet opening.

Support for weight of 150 lbs (68 kg), which includes 
microwave oven and items placed inside the microwave oven 
and upper cabinet.

Grounded electrical outlet inside upper cabinet. See 
“Electrical Requirements” section.

NOTES:

If installing the microwave oven near a left sidewall, make sure 
there is at least 3" (7.6 cm) of clearance between the wall and 
the microwave oven, so that the door can open fully.

Some cabinet and building materials are not designed to 
withstand the heat produced by the microwave oven for 
cooking. Check with your builder or cabinet supplier to make 
sure that the materials used will not discolor, delaminate or 
sustain other damages.

For gas cooktop, we recommend that combined cooking 
surface rating does not exceed 55,000 BTU/hr.

The microwave oven is set for recirculation mode. For external 
(wall or roof) venting, see “Venting Design Specifications” 
section.

Special Requirements

For Wall Venting Installation Only:

Cutout must be free of any obstructions so that the vent fits 
properly, and the damper blade opens freely and fully.

For Roof Venting Installation Only:

If you are using a rectangular to round transition piece, 
3" (7.6 cm) clearance needs to exist above the microwave 
oven so that the damper blade can open freely and fully. See 
“Rectangular to Round Transition” illustration in “Venting 
Design Specifications” section.

Dimension Requirements

Measuring tape

Pencil

Masking tape or thumbtacks

Scissors

T10 TORX

®† 

screwdriver

No. 3 Phillips screwdriver for 
1/4-20 x 3" bolts

Drill

3/16" (5 mm) and 3/8" 
(10 mm) drill bits

3/4" (19 mm) hole saw

Diagonal cutting pliers

Stud finder

7/16" socket wrench
(or box wrench) for 1/4" x 2" 
lag screws

1½" (3.8 cm) diam. hole drill 
bit for wood or metal 
cabinet

Keyhole saw

Caulking gun and 
weatherproof caulking 
compound

Duct tape

A. 1/4-20 x 3" round-head bolts (2)
B. 1/4-20 x 3" flat-head bolts (2)

C. Washers (2)
D. Toggle nuts (2)

E. 1/4" x 2" lag screws (2)

F. Mounting screws (3)

G. Power supply cord bushing (1)

H. Damper assembly (for wall or roof 

venting)

I. Vent deflector (for wall or roof 

venting)

Not Shown:
Upper cabinet template
Wall template
Mounting plate
Aluminum grease filters
Charcoal filters (Depending 
on model, charcoal filters 
may not be included. See 
Use and Care Guide.)

†®TORX is a registered trademark of Saturn Fasteners, Inc.

B

C

D

E

F

G

H

I

For proper ventilation, the vent 
screen must be free and clear of the 
surrounding cabinetry. The maximum 
allowable upper cabinet and side 
cabinet depth (from rear wall to front 
of cabinetry) must be no greater than 
the depth of the microwave oven 
metal outer wrapper (from back of 
microwave oven to the vent screen). 
NOTE: If the upper cabinet is deeper 
than the maximum allowable depth 
(see “Installation Dimensions” in this 
section), then the installer must 
space the microwave oven forward 
so that the vent screen is free and 
clear of any surrounding cabinetry.

A. Microwave oven metal 

outer wrapper

B. Vent screen

A

B

Содержание KHMC1857BSP

Страница 1: ...ttach Mounting Plate to Wall 8 Prepare Upper Cabinet 8 Install the Microwave Oven 9 Install Filters 10 Complete Installation 10 VENTING DESIGN SPECIFICATIONS 11 ASSISTANCE 12 Replacement Parts 12 W10502372A You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell yo...

Страница 2: ...g see Venting Design Specifications section Special Requirements For Wall Venting Installation Only Cutout must be free of any obstructions so that the vent fits properly and the damper blade opens freely and fully For Roof Venting Installation Only If you are using a rectangular to round transition piece 3 7 6 cm clearance needs to exist above the microwave oven so that the damper blade can open ...

Страница 3: ... cm Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING GROUNDING INSTRUCTIONS SAVETHESE INSTRUCTIONS For all cord connected appliances The microwave oven must be grounded In the event of an electrical short circuit groundin...

Страница 4: ...e Venting Design Specifications section NOTE Skip this section if you are using recirculation installation Keep the damper assembly in case the venting method is changed or the microwave oven is reinstalled in another location where wall or roof venting may be used To prepare the microwave oven for wall or roof venting the vent deflector L shaped metal bar must be installed and the appropriate dam...

Страница 5: ...ing as shown Then secure with mounting screw Roof Venting Installation Only To Remove Roof Damper Vent Cover 1 Locate the roof damper vent cover on the top of the microwave oven 2 Using diagonal wire cutting pliers gently snip out the damper vent cover at the perforations 3 Save the cover for possible change of venting method in the future NOTE Do not install damper assembly at this time A Mountin...

Страница 6: ...tions show examples of preferred installation configurations with the mounting plate No Wall Studs at End Holes Figure 1 No Wall Studs at End Holes Figure 2 NOTE If wall stud is within 6 15 2 cm of the vertical centerline see Mark Rear Wall section only recirculation or roof venting installation can be done Wall Stud at One End Hole Figure 3 Wall Studs at Both End Holes Figure 4 A End holes on mou...

Страница 7: ...ure out 6 15 2 cm on both sides of the centerline and mark 10 Measure down 4 10 2 cm from the mark made in Step 8 and mark 11 Using a straightedge draw the 2 horizontal level lines through the marks made in steps 8 and 10 12 Draw the 2 vertical plumb lines down from the marks made in Step 9 to complete the 12 x 4 30 5 x 10 2 cm rectangle This is the venting cutout area 13 Cut a 3 4 19 mm hole in o...

Страница 8: ...a lag screw into the other hole drilled in Step 2 of Installation for Wall Stud at One End Hole in the Drill Holes in Rear Wall section 7 Check alignment of mounting plate making sure it is level 8 Securely tighten the lag screw s and bolt Wall Studs at Both End Holes Figure 4 1 Position mounting plate on the wall 2 Insert lag screws into both end holes 3 Check alignment of mounting plate making s...

Страница 9: ... in the wall cutout 6 Push microwave oven against mounting plate and hold in place NOTE If microwave oven does not need to be adjusted skip steps 7 9 7 If adjustment is required rotate microwave oven downward Using 2 or more people lift microwave oven off of mounting plate and set aside on a covered surface 8 Loosen mounting plate screws Adjust mounting plate and retighten screws 9 Repeat steps 3 ...

Страница 10: ...peration of microwave oven by placing 1 cup 250 mL of water on the turntable and programming a cook time of 1 minute at 100 power Test vent fan and exhaust by operating the vent fan 4 If the microwave oven does not operate Check that a household fuse has not blown or that a circuit breaker has not tripped Replace the fuse or reset the circuit breaker If the problem continues call an electrician Ch...

Страница 11: ... the damper to open fully If venting through the roof and rectangular to round transition is used be sure there is at least 3 7 6 cm of clearance between the top of the microwave oven and the transition piece See Rectangular to Round Transition illustration Rectangular to Round Transition NOTE The minimum 3 7 6 cm clearance must exist between the top of the microwave oven and the rectangular to ro...

Страница 12: ...e oven model number and serial number Both numbers can be found on the model and serial number plate which is located behind the microwave oven door on the front frame of the microwave oven If you need additional assistance call us at our toll free number or visit our website listed in the User Instructions ReplacementParts If any of the installation hardware needs to be replaced call us at our to...