Make Gas Connection

To Assemble Pressure Regulator:

1. Stand the cooktop on its side or back.
2. Connect the flexible stainless steel connector to the pressure 

regulator using a 

³⁄₈

" male pipe thread adapter and nipple.

A combination of pipe fittings must be used to connect the 
cooktop to the existing gas line. Shown following is a typical 
connection. Your connection may be different, according to 
the supply line type, size and location.

3. Install the pressure regulator with the arrow pointing up 

toward the bottom of the burner box and in a position where 
you can reach the regulator cap.

IMPORTANT: All connections must be wrench-tightened. Do 
not make connections to the gas regulator too tight. Making 
the connections too tight may crack the regulator and cause a 
gas leak. Do not allow the regulator to turn on the pipe when 
tightening fittings.

Use only pipe-joint compound made for use with Natural and LP 
gas. 
Do not use TEFLON

®†

 tape. You will need to determine the fittings 

required depending on your installation.

Typical flexible connection

1. Apply pipe-joint compound made for use with LP gas to the 

smaller thread ends of the flexible connector adapters (see G 
in following illustration). 

2. Attach 1 adapter and nipple to the gas pressure regulator and 

the other adapter and nipple to the gas shutoff valve. Tighten 
both adapters and nipples.

3. Use a 

¹⁵⁄₁₆

" combination wrench and channel lock pliers to 

attach the flexible connector to the adapters. Check that 
connector is not kinked.   

Complete Connection

1. Open the manual shutoff valve in the gas supply line. The 

valve is open when the handle is parallel to the gas pipe.

2. Test all connections by brushing on an approved noncorrosive 

leak-detection solution. Bubbles will show a leak. Correct any 
leak found.

3. Remove surface burner caps and grates from parts package. 

Align notches in burner caps with pins in burner base. Burner 
caps should be level when properly positioned. If burner caps 
are not properly positioned, surface burners will not light. 
Place burner grates over burners and caps.

4. Plug into a grounded 3-prong outlet.

A. Access cap 
B. Rear of cooktop

C. Gas pressure regulator 
D. Up arrow. Regulator must be installed with 

arrow pointing up to cooktop bottom. 

A.

³⁄₈

" nipple

B.

³⁄₈

" adapter

C. Flexible connector 
D.

³⁄₈

" nipple

E. Gas pressure regulator

F.

³⁄₈

" adapter

G. Use pipe-joint compound

H. Manual gas shutoff valve

A

B

C

D

A

B

C

D

E

G

F

H

A. Closed valve
B. Open valve

A. Igniter electrode
B. Burner cap

C. Burner base

A

A

B

C

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

Содержание KGCC506RWW - 30" Gas Cooktop

Страница 1: ...llation instructions with the homeowner Homeowner Keep installation instructions for future reference Save installation instructions for local electrical inspector s use IMPORTANT Installateur Remettre les instructions d installation au propriétaire Propriétaire Conserver les instructions d installation pour référence ultérieure Conserver les instructions d installation pour consultation par l ins...

Страница 2: ...en dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The cooktop is designed to hang from the countertop by its side or rear flanges WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to preve...

Страница 3: ...r obstruction in base cabinet is required The drawer depth may need to be shortened to avoid interfering with the regulator If installing a hood above the range follow the hood instructions for dimensional clearances above the cooktop surface A 21 53 4 cm B 31 79 8 cm on 30 76 2 cm models 37 95 4 cm on 36 91 4 cm models C 2 7 3 cm A 20 51 5 cm B 30 76 8 cm on 30 76 2 cm models 36 92 5 cm on 36 91 ...

Страница 4: ...er conversion for use with LP gas This cooktop is factory set for use with Natural gas To convert to LP gas see the Gas Conversion instructions provided in the literature package The model serial rating plate located on the underside of the burner box has information on the types of gas that can be used If the types of gas listed do not include the type of gas available check with the local gas su...

Страница 5: ... inlet pressure Burner Input Requirements Input ratings shown on the model serial rating plate are for elevations up to 2 000 ft 609 6 m For elevations above 2 000 ft 609 6 m ratings are reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level not applicable for Canada Gas Supply Pressure Testing Line pressure testing above psi gauge 14 WCP The cooktop and its individual manual shutoff val...

Страница 6: ... hold brackets in place when cooktop is put in cutout 7 Turn the cooktop right side up and place in cutout NOTE Make sure that the front edge of the cooktop is parallel to the front edge of the countertop If repositioning is needed lift entire cooktop up from cutout to prevent scratching the countertop 8 Loosen the screws and rotate the brackets so that they are perpendicular to the edge of the bu...

Страница 7: ...ulator and the other adapter and nipple to the gas shutoff valve Tighten both adapters and nipples 3 Use a combination wrench and channel lock pliers to attach the flexible connector to the adapters Check that connector is not kinked Complete Connection 1 Open the manual shutoff valve in the gas supply line The valve is open when the handle is parallel to the gas pipe 2 Test all connections by bru...

Страница 8: ...ing the proper burner operation turn the control knobs to OFF If burners do not light properly Turn surface burner control knob to the OFF position Check that the power supply cord is plugged in and the circuit breaker has not tripped or the fuse blown Check that the gas shutoff valves are set to the open position Check that burner caps are properly positioned on burner bases Recheck operation of ...

Страница 9: ...RAL 5 16 WIDE BLADE BK BK PLUG LINE GROUND CONNECT 250 TERMINALS GROUND SPARK MODULE 120 VAC 60 Hz 1 PHASE 15 OR 20 AMP VALVE SWITCHES ROUND BLADE IGNITER ELECTRODES ELECTRIC CIRCUIT CLOSED WHEN KNOB IS ROTATED 55 TO 95 COUNTERCLOCKWISE FROM OFF 1 4 WIDE BLADE W GND 5 Y OR BR 5 PLACES SWITCHES ON VALVES 4 3 2 1 N L1 BK G OR G Y G OR G Y NEUTRAL 5 16 WIDE BLADE BK BK PLUG LINE 1 4 WIDE BLADE GROUND...

Страница 10: ...essures graves à vous et à d autres Tous les messages de sécurité suivront le symbole d alerte de sécurité et le mot DANGER ou AVERTISSEMENT Ces mots signifient AVERTISSEMENT Pour votre sécurité les renseignements dans ce manuel doivent être observés pour réduire au minimum les risques d incendie ou d explosion ou pour éviter des dommages au produit des blessures ou un décès Ne pas entreposer ni u...

Страница 11: ...inimales des dégagements de séparation Une source d électricité avec liaison à la terre est nécessaire Voir la section Spécifications électriques Une source de gaz adéquate doit être disponible Voir la section Spécifications de l alimentation en gaz De par sa conception la table de cuisson est suspendue sur le plan de travail par les rebords des côtés ou de l arrière Veiller à placer les sources d...

Страница 12: ...2 cm sur les modèles de 30 36 91 4 cm sur les modèles de 36 B Zone de matière combustible au dessus du plan de travail espace délimité par des lignes pointillées ci dessus C Distance de séparation de 30 76 2 cm ou plus entre le plan de travail et le fond d un placard métallique ou de bois non protégé distance de séparation de 24 61 cm ou plus si le fond du placard de métal ou de bois est protégé p...

Страница 13: ...en vigueur National Fuel Gas Code ANSI Z223 1 ou CAN CGA B149 Type de gaz Gaz naturel La conception de cette table de cuisson a été homologuée par CSA International pour l alimentation au gaz naturel ou pour l alimentation au propane après conversion adéquate Cette table de cuisson a été configurée à l usine pour l alimentation au gaz naturel Pour effectuer la conversion pour une alimentation au p...

Страница 14: ... La canalisation doit se trouver en un endroit facilement accessible pour les manœuvres d ouverture fermeture Ne pas entraver l accès au robinet d arrêt manuel Le robinet d arrêt manuel est prévu pour ouvrir ou fermer l alimentation en gaz de la table de cuisson Régulateur de pression de gaz Le régulateur de pression de gaz fourni avec cette table de cuisson doit être utilisé La pression d aliment...

Страница 15: ...n aux extrémités de la boîte des brûleurs Il s agit de l emplacement recommandé Des brides de fixation peuvent être installées à l avant et à l arrière de la partie inférieure de la boîte de brûleur si nécessaire 2 Les brides de fixation peuvent être installées avant ou après le positionnement de la table de cuisson dans l ouverture Procéder aux étapes suivantes pour l option choisie Installation ...

Страница 16: ...liser une combinaison de raccords de tuyauterie pour raccorder la table de cuisson à l alimentation en gaz existante On voit ci dessous une illustration d un raccordement typique Le raccordement peut varier selon le type d alimentation la dimension et l emplacement 3 Orienter la flèche du détendeur vers le haut vers le fond de la boîte des brûleurs et orienter horizontalement le détendeur de telle...

Страница 17: ...uton de commande d un brûleur de la table de cuisson à la position LITE allumage le système génère des étincelles pour l allumage du brûleur La génération d étincelles se poursuit aussi longtemps que le bouton de commande est laissé à la position LITE Contrôle du fonctionnement des brûleurs de surface Enfoncer et tourner les boutons de commande des brûleurs de surface à la position LITE Le gaz doi...

Страница 18: ...inimum on doit observer des flammes stables bleues de 0 64 cm S il est nécessaire de régler la taille des flammes pour le débit thermique minimum La vis de réglage au centre de la tige de commande du robinet permet de régler la taille des flammes La tige de commande est située directement au dessous du bouton de commande 1 Ôter le bouton de commande 2 Immobiliser la tige de commande avec une pince...

Страница 19: ...20 A COMMUTATEURS DE SOUPAPES ÉLECTRODES D ALLUMAGE BROCHE D ALIMENTATION DE 1 4 PO DE LARGE BROCHE RONDE DE MISE À LA TERRE TERMINAUX DE CONNECTION 0 250 CIRCUIT ÉLECTRIQUE FERMÉ LORSQUE LE BOUTON EST TOURNÉ DE 55 À 95 DANS LE SENS ANTI HORAIRE À PARTIR DE OFF COMMUTATEURS SUR SOUPAPES BROCHE NEUTRE 5 16 PO DE LARGE VE OU VE JA 5 JA OU MAR 5 PLCS 4 3 2 1 N L1 BL N N N FICHE TERRE TERRE TERRE MODU...

Страница 20: ...8286304 2005 Whirlpool Corporation All rights reserved Tous droits réservés 4 05 Printed in U S A Imprimé aux É U ...

Отзывы: