13
UNIVERSAL FAILURE & ERROR CODES
FFFFF 11111
=
Electronics Subsystem Failure. Replace the electronic control board.
E0 = EEPROM communication error.
E1 = EEPROM checksum error.
E2 = A/D converter error (is there an error bit in the microprocessor?; does this mean
lost a voltage rail?)
E3 = Configuration jumper (cavity size or gas/electric) does not match setting defined
in EEPROM (this was designed to notify the installer that the jumpers were not
reconnected properly).
E5 = Calibration shifted.
E9 = Stack overflow.
FFFFF 22222
=
Keypad Subsystem Failure. Replace the keypad if properly connected and this F code
is displayed.
E0 = Shorted keypad or keypad stuck.
E1 = Keypad or keytail not connected.
E4 = Keypads unsettled (applies to capacitive glass when a constant reading cannot
be taken).
E5 = Cancel key low or open.
FFFFF 33333
=
Cavity Temperature Sensor Failure. Check for welded relays. If okay, replace the tem-
perature sensor.
E0 = Sensor open.
E1 = Sensor shorted.
E2 = Non self-clean over-temperature (usually 550˚F).
E3 = Self-clean over-temperature (usually 900˚F).
FFFFF 44444
=
Meat Probe Failure. Check for proper resistance on probe. If okay, replace the meat
probe jack.
E1 = Meat probe shorted.
FFFFF 55555
=
Latch Subsystem Failure. Check for proper latch movement, switch actuation, and
clearance between the latch and door.
E0 = Latch switch does not agree with door switch (i.e. Iatch in locked position with
door open).
E1 = Latch will not lock.
E3 = Loss of ground or L1 to N is reversed. Check to make sure that the voltage from
L1 to ground is 120-volts AC.
E5 = Self-clean temperature set point is not reached within the required time range
(usually 30 - 45 minutes).
E7 = Latch will not unlock.
FFFFF 6
66
66
=
Electronics Over-Temperature. Check the blower and ventilation system.
E0 = Over-temperature with blower on high speed.
E1 = Over-temperature with blower on low speed.
E2 = Over-temperature with blower off.
FFFFF 77777
=
Digital Switch Signal (i.e. 5 vdc @ 1kHz) Failure. Check for shorted door or latch switch
wiring to chassis ground.
E0 = Signal line shorted to ground.
Содержание KESC300BAL1
Страница 14: ...14 WIRING DIAGRAMS Tech Sheet 9752381 9750877 ...
Страница 15: ...15 Tech Sheet 9751598 ...
Страница 16: ...16 Tech Sheet 9752669 ...
Страница 17: ...17 Tech Sheet 4448437 ...
Страница 18: ...18 Tech Sheet 4450310 ...
Страница 19: ...19 Tech Sheet 4450809 ...
Страница 20: ...20 Tech Sheet 4450810 ...
Страница 21: ...21 Tech Sheet 4450811 ...
Страница 22: ...22 Tech Sheet 4451057 ...
Страница 23: ...23 Tech Sheet 4452023 ...
Страница 24: ...24 Tech Sheet 4452024 ...
Страница 25: ...25 Tech Sheet 4452025 ...
Страница 26: ...26 Tech Sheet 4452026 ...
Страница 27: ...27 Tech Sheet 4452028 ...
Страница 28: ...28 Tech Sheet 4454768 ...
Страница 29: ...29 Tech Sheet 4454769 ...
Страница 30: ...30 Tech Sheet 4454770 ...
Страница 31: ...31 Tech Sheet 4454771 ...
Страница 32: ...32 Tech Sheet 4454773 ...