UNIVERSAL FAILURE & ERROR CODES

FFFFF 11111

 =

Electronics Subsystem Failure. Replace the electronic control board.
E0 = EEPROM communication error.
E1 = EEPROM checksum error.
E2 = A/D converter error (is there an error bit in the microprocessor?; does this mean
     lost a voltage rail?)
E3 = Configuration jumper (cavity size or gas/electric) does not match setting defined
     in EEPROM (this was designed to notify the installer that the jumpers were not
     reconnected properly).
E5 = Calibration shifted.
E9 = Stack overflow.

FFFFF 22222

 =

Keypad Subsystem Failure. Replace the keypad if properly connected and this F code
is displayed.
E0 = Shorted keypad or keypad stuck.
E1 = Keypad or keytail not connected.
E4 = Keypads unsettled (applies to capacitive glass when a constant reading cannot
     be taken).
E5 = Cancel key low or open.

FFFFF 33333

 =

Cavity Temperature Sensor Failure. Check for welded relays. If okay, replace the tem-
perature sensor.
E0 = Sensor open.
E1 = Sensor shorted.
E2 = Non self-clean over-temperature (usually 550˚F).
E3 = Self-clean over-temperature (usually 900˚F).

FFFFF 44444

 =

Meat Probe Failure. Check for proper resistance on probe. If okay, replace the meat
probe jack.
E1 = Meat probe shorted.

FFFFF 55555

 =

Latch Subsystem Failure. Check for proper latch movement, switch actuation, and
clearance between the latch and door.
E0 = Latch switch does not agree with door switch (i.e. Iatch in locked position with
     door open).
E1 = Latch will not lock.
E3 = Loss of ground or L1 to N is reversed. Check to make sure that the voltage from
     L1 to ground is 120-volts AC.
E5 = Self-clean temperature set point is not reached within the required time range
     (usually 30 - 45 minutes).
E7 = Latch will not unlock.

FFFFF 6

66

66

 =

Electronics Over-Temperature. Check the blower and ventilation system.
E0 = Over-temperature with blower on high speed.
E1 = Over-temperature with blower on low speed.
E2 = Over-temperature with blower off.

FFFFF 77777

 =

Digital Switch Signal (i.e. 5 vdc @ 1kHz) Failure. Check for shorted door or latch switch
wiring to chassis ground.
E0 = Signal line shorted to ground.

Содержание KESC300BAL1

Страница 1: ...epartment Failure Codes Wiring Diagrams for KitchenAid Freestanding Slide In Ranges And Built In Ovens All rights reserved No portion of this document may be reproduced in any form without written permission from Whirlpool Corporation Part No 4317266 ...

Страница 2: ...NTER CANCEL OFF DELAY TIMED KITCHEN TIMER 888 88 88 BAKE BROIL BAKE BROIL ROAST CLEAN MEATS BAKED GOODS OTHER FOODS COOK TIME START CANCEL CONVECT FULL MEAL CLOCK SET START HR MIN MIN SEC STOP TIME ON ON LIGHT SURFACE LIGHT EASY CONVECT CONVECTION TIMER OFF OVEN LIGHT SET START CANCEL OFF 888 88 88 8 30 88 88 88 88 1 2 3 4 5 6 7 8 0 9 BAKE BROIL CLEAN COOK TIME START CANCEL SURFACE LIGHT CLOCK SET...

Страница 3: ...TART TIME 2 00 12 00 11 30 1 30 350 BAKED GOODS OTHER FOODS COOK TIME CLEAN MEATS OVEN LIGHT CONVECT FULL MEAL CONTROL LOCK START CANCEL OFF BROIL MAXI ECONO SET START CANCEL STOP TIME CLOCK SET START TIMER CONVERSION 1 2 3 4 5 6 7 8 9 0 Superba EasyConvect F BAKE BAKE BROIL ROAST CONVECTOIN ON ON COOK TIME UPPER OVEN LOWER OVEN 2 00 350 450 BAKE CLEAN COOK TIME UPPER OVEN CANCEL OFF LOWER OVEN CA...

Страница 4: ... LOCATIONS 12345 12345 12345 12345 12345 12345 12345 1234 1234 1234 1234 1234 1234 Behind Control Panel Behind Control Panel 12345 12345 12345 12345 Behind Control Panel 12345 12345 12345 12345 Behind Control Panel ...

Страница 5: ... NON CONVECTION KITCHENAID TIMER THERMOSTAT KITCHENAID TIMER THERMOSTAT KITCHENAID TIMER THERMOSTAT KITCHENAID TIMER THERMOSTAT KITCHENAID TIMER ASSEMBLY KITCHENAID TIMER ASSEMBLY KITCHENAID TIMER ASSEMBLY KITCHENAID TIMER ASSEMBLY A C T CONVECTION A C T CONVECTION A C T CONVECTION A C T CONVECTION TIMER CONVECTION A C T CONVECTION A C T CONVECTION TIMER CONVECTION KITCHENAID CONVECTION KITCHENAID...

Страница 6: ... KITCHENAID TIMER ASSY CONV KITCHENAID TIMER ASSY CONV KITCHENAID TIMER ASSY CONV KITCHENAID TIMER CONVECTION KITCHENAID TIMER CONVECTION KITCHENAID TIMER CONVECTION KITCHENAID TIMER CONVECTION A C T NON CONVECTION A C T NON CONVECTION KITCHENAID TIMER THERMOSTAT KITCHENAID TIMER THERMOSTAT A C T CONVECTION A C T CONVECTION A C T CONVECTION KITCHENAID CONVECTION KITCHENAID CONVECTION KITCHENAID TI...

Страница 7: ... TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CO...

Страница 8: ...MER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION TIMER CONVECTION D A C 3 CONTROL CONVECTION D A C 3 CONTROL CONVECTION D A C 3 CONTROL CONVECTION Tech Sheet Part 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 9752669 ...

Страница 9: ...451257 4451258 4451259 4451260 4451261 4451263 4451264 4451276 4451277 4451279 4451280 4451279 4451285 4451286 4451288 4451289 4451291 4451292 4451293 4451297 4451294 4451295 4451296 BUILT IN MODEL OVENS TOUCH PANEL COLORS NOTE The charts on the following pages show only white touch panels For other touch panel colors refer to the above chart ...

Страница 10: ...mal Single Oven Thermal Single Oven Thermal Single Oven Thermal Single Oven Thermal Single Oven Thermal Single Oven Thermal Single Oven Thermal Single Oven Thermal Double Oven Thermal Double Oven Thermal Double Oven Thermal Double Oven Thermal Double Oven Thermal Convection Thermal Convection Thermal Convection Thermal Convection Thermal Convection Thermal Convection Thermal Convection Thermal Con...

Страница 11: ...Convection Upper Thermal Convection Upper Thermal Convection Upper Thermal Convection Upper Thermal Convection Upper Thermal Convection Upper Thermal Convection Upper Thermal Convection Upper Thermal Convection Upper Thermal Convection Double Thermal Convection Double Thermal Convection Double Thermal Convection Double Thermal Convection Double Microwave Thermal Oven Microwave Thermal Oven Microwa...

Страница 12: ...tween Fahrenheit F and Celsius C 0 Displays the last failure F E code that was used and the latest ROM revision 1 Shows the type of range the electronic control is configured for 3 Locks out the keypads so they cannot be used 6 Switches the range to SABBATH mode 7 Changes the tone frequency F F F F F1 1 1 1 1 Control out of calibration Place the sensor in ice water 32 F and check the resistance 10...

Страница 13: ...ensor open E1 Sensor shorted E2 Non self clean over temperature usually 550 F E3 Self clean over temperature usually 900 F F F F F F 4 4 4 4 4 Meat Probe Failure Check for proper resistance on probe If okay replace the meat probe jack E1 Meat probe shorted F F F F F 5 5 5 5 5 Latch Subsystem Failure Check for proper latch movement switch actuation and clearance between the latch and door E0 Latch ...

Страница 14: ...14 WIRING DIAGRAMS Tech Sheet 9752381 9750877 ...

Страница 15: ...15 Tech Sheet 9751598 ...

Страница 16: ...16 Tech Sheet 9752669 ...

Страница 17: ...17 Tech Sheet 4448437 ...

Страница 18: ...18 Tech Sheet 4450310 ...

Страница 19: ...19 Tech Sheet 4450809 ...

Страница 20: ...20 Tech Sheet 4450810 ...

Страница 21: ...21 Tech Sheet 4450811 ...

Страница 22: ...22 Tech Sheet 4451057 ...

Страница 23: ...23 Tech Sheet 4452023 ...

Страница 24: ...24 Tech Sheet 4452024 ...

Страница 25: ...25 Tech Sheet 4452025 ...

Страница 26: ...26 Tech Sheet 4452026 ...

Страница 27: ...27 Tech Sheet 4452028 ...

Страница 28: ...28 Tech Sheet 4454768 ...

Страница 29: ...29 Tech Sheet 4454769 ...

Страница 30: ...30 Tech Sheet 4454770 ...

Страница 31: ...31 Tech Sheet 4454771 ...

Страница 32: ...32 Tech Sheet 4454773 ...

Отзывы: