Страница 1: ...nt 21 Verification de I emplacement de la bride antibasculement 22 Reglage de I aplomb de la cuisiniere 22 Achever I installation 22 Deplacement de la cuisiniere 23 RANGESAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symb...

Страница 2: ...el serial rating plate The modeIlserial rating plateis locatedbehindthe control panel The rangeshouldbe located forconvenient use inthe kitchen To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located above the surface units should be avoided If cabinet storage is to be provided the risk can be reduced by installing a range hood that projects horiz...

Страница 3: ... be rotated up from behind the control panel for viewing from the front of the range Excludes handle Dimension given is from wall to front of oven door and will vary based on electric outlet receptacle installation A 18 45 7 cm upper cabinet to countertop B 13 33 0 cm upper cabinet depth C 30 76 2 cm min opening width D For minimum clearance to the top of the cooktop see NOTE E 30 76 2 cm min open...

Страница 4: ...f connecting to a 4 wire system This range is manufactured with the ground connected to the neutral by a link The ground must be revised so the green ground wire of the 4 wire power supply cord is connected to the cabinet See Electrical Connection Section Grounding through the neutral conductor is prohibited for new branch circuit installations 1996 NEC mobile homes and recreational vehicles or an...

Страница 5: ...ADA Check with a qualified electrical installer if you are not sure the range is properly grounded Range Rating Specified Rating of Power Supply Cord Kit and Circuit Protection 120 240 Volts 120 208 Volts Amps 8 8 16 5 KW 7 8 12 5 KW 40 or 50 16 6 22 5 KW 12 6 18 5 KW 50 The NEC calculated load is less than the total connected load listed on the model serial rating plate If connecting to a 50 amp ...

Страница 6: ...with the range on its back or with the range supported on 2 legs after the range has been placed back to a standing position NOTE To place range back up into a standing position put a sheet of cardboard or hardboard in front of range Using 2 or more people stand range back up onto the cardboard or hardboard Tip Over Hazard A child or adult can tip the range and be killed Connect anti tip bracket t...

Страница 7: ... can be installed on either the left side or right side of the cutout Position mounting bracket in cutout so that right or left edge of the bracket is _ e 2 4 cm from the marked edge of the range as shown 4 A B Drill two 3 0 mm holes that correspond to the bracket holes of the determined mounting method See the following Wall Mounting A B A 12 x 1 screws B Anti tip bracket 5 A 12 x 1 screws B Anti...

Страница 8: ...cal shock 1 2 3 Disconnect power Use Phillips screwdriver to remove the terminal block cover screw located on the back of the range Pull cover down and toward you to remove cover Remove plastic tag holding three 10 32 hex nuts from the middle post of the terminal block 4 Add strain relief Style 1 Power supply cord strain relief Assemble a UL listed strain relief in the opening A A UL listed strain...

Страница 9: ...plete installation following instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not available Electrical Connection Options If your home has And you will be Go to Section connecting to 4 wire receptacle A UL listed NEMA type 14 50R 250 volt minimum 40 amp range power supply cord 4 wire connection Power supply cord 4 wire direct A fused disconnect or circuit ...

Страница 10: ...re F Line 2 red 6 Connect line 1 black and line 2 red wires to the outer terminal block posts with 10 32 hex nuts 7 Securely tighten hex nuts NOTE For power supply cord replacement only use a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use with nominal 13 8 3 5 cm diameter connection opening with ring terminals and marked for use with ranges 8 Replace terminal block...

Страница 11: ...6 cm to expose wires Strip the insulation back 1 2 5 cm from the end of each wire 1Jt 4 wire Connection Direct Wire Use this method for New branch circuit installations 1996 NEC Mobile homes Recreational vehicles In an area where local codes prohibit grounding through the neutral 1 Part of metal ground strap must be cut out and removed 2 3 _ L A Metal ground strap B Discard C Ground link screw A B...

Страница 12: ...nection Direct Wire Use this method only if local codes permit connecting ground conductor to neutral supply wire 1 Pull the conduit through the hole and conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block C 2 F A Terminal block B Ground link screw C Cord conduit plate D Line 2 red wire E Bare green ground wire F Line 1 black wire Attach terminal l...

Страница 13: ...e back into position 5 Check that rear leveling leg is engaged in anti tip bracket NOTE Range must be level for satisfactory baking performance 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See Level Range ...

Страница 14: ...ly cord 5 To check that anti tip bracket is installed use a flashlight and look underneath the bottom of the range Look for the anti tip bracket securely attached to floor or wall Slide range back so rear range foot is under anti tip bracket Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical sho...

Страница 15: ...15 ...

Страница 16: ...nt Risque possible de d_cbs ou de blessure grave si vous ne suivez pas imm_diatement les instructions Risque possible de d_cbs ou de blessure grave si vous ne suivez pas les instructions Tousles messages de s_curit_ vous diront quel est le danger potentiel et vous disent comment r_duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions Risque de basculement Un...

Страница 17: ... au dessus des plaques de cuisson chaudes les placards de rangement au dessus des plaques doivent _tre evites Si des placards de rangement sont envisages le risque peut _tre reduit par I installation d une hotte de cuisine depassant le bas des placards d au moins 5 12 7 cm horizontalement Respecter les dimensions indiquees pour les ouvertures decouper dans les placards Ces dimensions constituent l...

Страница 18: ...nde afin qu elles soient visibles depuis I avant de la cuisiniere Poignee non comprise La dimension fournie correspond la distance du mur I avant de la porte du four et varie en fonction de I installation de la prise electrique murale 1 t j J K A 18 45 7 cm entre le placard F Laporte ou charniere du sup_rieur et le plan de travail placard ne doit pas d_passer B Profondeur des placards I int_rieur ...

Страница 19: ...iaison la terre de la cuisiniere consulter un electricien qualifi Puissance nominale de la Intensit_ nominale cuisini_re sp_cifi_e du cordon d alimentation et de la protection du circuit 120 240 volts 120 208 volts A 8 8 16 5 kW 7 8 12 5 kW 40 ou 50 16 6 22 5 kW 12 6 18 5 kW 50 La charge NEC calculee est inferieure la charge totale connectee indiqu6e sur la plaque signaletique En cas de raccordeme...

Страница 20: ... effectue alors que la cuisiniere repose sur sa partie posterieure ou qu elle est soutenue par 2 pieds apres avoir ete replacee en position verticale RFMARQUF Pour replacer la cuisiniere en position verticale placer un carton ou un panneau de fibres dur devant la cuisiniere A I aide de deux personnes ou plus relever la cuisiniere et la placer sur le carton ou le panneau de fibres dur Risque de bas...

Страница 21: ...upage Positionner la bride de montage dans la zone decoup6e de fagon ce que le bord droit ou gauche de la bride se trouve l_e 2 4 cm de I emplacement du bord de la cuisiniere tel qu illustr A B A Bride antibasculement B Marquage de I emplacement du bord de la cuisiniere C 15 16 2 4 cm Percer deux trous de 3 0 mm qui correspondent aux trous de la bride selon la methode de montage determin6e Voir ci...

Страница 22: ...ce de tousles outils 3 I 1iminer recycler tous les materiaux d emballage 4 Verifier que la cuisiniere est d aplomb Voir Reglage de I aplomb de la cuisiniere 5 Utiliser une solution d eau tiede et de nettoyant menager doux pour eliminer tout residu de cire laiss par les materiaux d emballage Secher parfaitement avec un linge doux Pour plus d informations lire la section Entretien de la cuisiniere d...

Страница 23: ...la cuisiniere vers I avant 2 Debrancher le cordon d alimentation electrique 3 Effectuer le nettoyage ou I entretien 4 Brancher le cordon d alimentation electrique 5 Pour s assurer que la bride antibasculement est installee utiliser une lampe de poche pour examiner le dessous de la cuisiniere Verifier que la bride antibasculement est bien fixee au plancher ou au mur Faire glisser la cuisiniere vers...

Страница 24: ...W10289536A 2010 All rights reserved Tous droits reserves 1 lO Printed in U S A Imprime aux E U ...

Отзывы: