5-5
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
WARNING
Refer to page 4-6 for the procedure for servic-
ing the oven light & control power transformers.
1.
Disconnect the electrical power to the
oven.
2.
Disconnect the wires from the transformer
under test.
3.
Set the ohmmeter to the R x 1 scale.
4.
To test the oven light transformer:
a) Touch the ohmmeter leads to the LINE
terminals. The meter should indicate
between 40 and 45
Ω
.
b) Touch the ohmmeter leads to the LOAD
terminals. The meter should indicate
less than 1
Ω
.
5.
To test the control power transformer:
a) Touch the ohmmeter leads to the LINE
terminals. The meter should indicate
between 85 and 90
Ω
.
b) Touch the ohmmeter leads to the LOAD
terminals. The meter should indicate
between 1 and 6
Ω
.
LOAD
OVEN LIGHT & CONTROL POWER
TRANSFORMERS
LINE