Electrical Requirements

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.

Check with a qualified electrician if you are not sure whether the 
side burner is properly grounded.

A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical supply is 
required.

It is recommended that a separate circuit servicing only this side 
burner be provided.

The model/serial number rating plate is located on the right-hand 
side panel. See the following illustration.

Recommended Ground Method

The outdoor side burner, when installed, must be electrically 
grounded in accordance with local codes or, in the absence of 
local codes, with the National Electrical Code ANSI/NFPA 70, or 
Canadian Electrical Code, CSA C22.1.

Copies of the standards listed above may be obtained from:

CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575

National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269

Gas Supply Requirements

Observe all governing codes and ordinances.

IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149.1 - latest 
edition.

IMPORTANT: The side burner must be connected to a regulated 
gas supply.

Refer to the model/serial rating plate for information on the type 
of gas that can be used. If this information does not agree with 
the type of gas available, check with your local gas supplier.

Gas Conversion:
No attempt shall be made to convert the side burner from the gas 
specified on the model/serial rating plate for use with a different 
gas type without consulting the serving gas supplier. The 
conversion kits specified must be used.

A. Model/serial number plate

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

A

A. 3 prong ground plug
B. 3-prong polarized type outdoor GFI outlet

C. Ground prong

A

B

C

WARNING

Explosion Hazard

Use a new CSA International approved “outdoor” 
gas supply line.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 11” (28 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Содержание KBZU122T

Страница 1: ...entretien Au Canada pour assistance installation ou service composez le 1 800 807 6777 ou visitez notre site Web à www Kitchenaid ca Table of Contents Table des matières 2 IMPORTANT Save for local electrical inspector s use Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference IMPORTANT À conserver pour consultation par l inspect...

Страница 2: ...In the U S A 15 Accessories 15 In Canada 15 WARRANTY 16 TABLE DES MATIÈRES SÉCURITÉ DU BRÛLEUR LATÉRAL ENCASTRÉ D EXTÉRIEUR 18 EXIGENCES D INSTALLATION 20 Outillage et pièces 20 Exigences d emplacement 20 Dimensions du produit 20 Dimensions de l ouverture à découper dans le placard 21 Spécifications électriques 24 Spécifications de l alimentation en gaz 24 INSTRUCTIONS D INSTALLATION 26 Installati...

Страница 3: ... or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance 2 An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 Open lid 4 If odor continues keep away from the appliance and immediately call your gas supplier or your fire depa...

Страница 4: ...use only replacement hoses specified for use with the outdoor cooking gas appliance Visually check the burner flames They should be blue Slight yellow tipping is normal for LP gas Check and clean burner venturi tube for insects and insect nest A clogged tube can lead to fire under the outdoor cooking gas appliance The LP gas supply cylinder to be used must be constructed and marked in accordance w...

Страница 5: ...sembly LocationRequirements Select a location that provides minimum exposure to wind and traffic paths The location should be away from strong draft areas Do not obstruct flow of combustion and ventilation air Clearance to combustible construction for built in outdoor side burners A minimum of 24 58 cm must be maintained between the sides and back and any combustible construction A 24 58 cm minimu...

Страница 6: ...ained from CSA International 8501 East Pleasant Valley Rd Cleveland Ohio 44131 5575 NOTE The outdoor side burner drops into the enclosure opening and is supported by its side flanges No bottom support is needed The dimension chart and illustration below include cutout dimensions and minimum spacing requirements for all built in outdoor products The illustration is for reference The design of your ...

Страница 7: ...cket 35 90 2 cm 26 66 0 cm Cutout Dimensions Built in Grill Grill Size Dimension C Dimension D Dimension E 27 68 6 cm 29 75 2 cm 10 27 3 cm 22 58 1 cm 36 91 4 cm 38 98 1 cm 10 27 3 cm 22 58 1 cm 48 121 9 cm 50 128 6 cm 10 27 3 cm 22 58 1 cm Cutout Dimensions Built in Grill with Insulated Jacket Grill Size Dimension C Dimension D Dimension E 27 68 6 cm 33 83 8 cm 11 29 8 cm 24 61 0 cm 36 91 4 cm 42...

Страница 8: ...ttom of the enclosure and the bottom opening is to be a minimum of 10 in 2 64 5 cm2 All vent openings are to be unobstructed Every opening is to be a minimum of 0 32 cm wide Cutout Dimensions Built in Access Doors Door Size Dimension F Dimension L 18 45 7 cm 16 41 1 cm 1 3 8 cm 27 68 6 cm 25 63 8 cm 1 3 8 cm 30 76 2 cm 28 71 4 cm 1 3 8 cm 36 91 4 cm 34 86 7 cm 1 3 8 cm 48 121 9 cm 46 117 2 cm 1 3 ...

Страница 9: ...form with American National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 1 latest edition IMPORTANT The side burner must be connected to a regulated gas supply Refer to the model serial rating plate for information on the type of gas that can be used If this information does not agree with the type of gas available check with your local gas supplier Gas Conversion No ...

Страница 10: ...s supply piping system at test pressures equal to or less than psig 3 5 kPa Natural Gas Side burners are equipped for use with Natural gas They are design certified by CSA International for LP propane or butane gases with appropriate conversion Side burners are set for natural gas use and have a pressure regulator with 1 3 cm female pipe threads The supply line shall be equipped with an approved s...

Страница 11: ...line is recommended Pipe joint compounds suitable for use with Natural gas must be used Do not use TEFLON tape 3 Using a wrench to tighten connect the gas supply to the side burner Use pipe joint compound on all non flared male threads Do not kink or damage the flexible connector when moving the side burner 4 Open the manual shutoff valve in the gas supply line The valve is open when the handle is...

Страница 12: ...hat adjustments be made by a qualified person Checking and adjusting the burner flames requires removing the grate Low flame adjustment If flame goes out on the LO setting the low flame setting must be adjusted 1 Light the burner and turn control knob to its lowest setting and remove knob 2 Hold the valve stem with pliers and insert a thin flat blade screwdriver into the shaft 3 Watch the flame an...

Страница 13: ...ANT If burner does not light immediately turn the burner knob to OFF and wait 5 minutes before relighting Manually lighting the side burner 1 Remove the outdoor side burner cover 2 Remove the manual lighting extension see following illustration and attach a match to the split ring 3 Strike the match to light it 4 Guide the match to the burner you wish to light 5 Do not lean over the side burner Pu...

Страница 14: ... followed by rinsing with clean warm water Wipe the surface completely dry with a soft cloth For tough spots or baked on grease use Kitchen and BBQ Grill Degreaser Part Number 31617 a commercial degreaser designed for stainless steel See Assistance or Service section to order INTERIOR Discoloration of stainless steel on these parts is to be expected due to intense heat from the burners Always rub ...

Страница 15: ...g impaired limited vision etc Referrals to local dealers repair parts distributors and service companies KitchenAid designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the KitchenAid designated service company in your area you can also look in your telephone directory Yellow Pages For further assistan...

Страница 16: ...product is used for other than normal single family household use or when it is used in a manner that is contrary to published user or operator instructions and or installation instructions 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or use of consumables or cleaning products ...

Страница 17: ...stallation date for in warranty service Write down the following information about your major appliance to better help you obtain assistance or service if you ever need it You will need to know your complete model number and serial number You can find this information on the model and serial number label located on the product Dealer name____________________________________________________ Address...

Страница 18: ...pareil 2 Éteindre toute flamme nue 3 Ouvrir le couvercle 4 Si l odeur persiste s éloigner de l appareil et appeler immédiatement le fournisseur en gaz ou les pompiers DANGER AVERTISSEMENT 1 Ne pas remiser ou utiliser de l essence ou tout autre liquide ou vapeur inflammable à proximité de cet appareil ou de tout autre appareil 2 Ne pas remiser une bouteille de gaz de pétrole liquéfié non raccordée ...

Страница 19: ...cifiés pour utilisation avec l appareil de cuisson à gaz d extérieur Inspecter visuellement les flammes du brûleur Elles doivent être bleues Avec du gaz de pétrole liquéfié il est normal d observer une légère pointe jaune Nettoyer le tube du brûleur de la buse et vérifier l absence d insectes ou de nids d insectes Un tube obstrué peut entraîner un feu sous l appareil de cuisson à gaz d extérieur L...

Страница 20: ...mplacement Sélectionner un emplacement où l exposition au vent est faible et les passages peu nombreux L emplacement ne doit pas se trouver dans une zone à forts courants d air Ne pas obstruer le flux de combustion et de ventilation Distance de séparation entre les constructions combustibles et les brûleurs latéraux encastrés d extérieur Un minimum de 24 58 cm doit être maintenu entre les côtés et...

Страница 21: ...8501 East Pleasant Valley Rd Cleveland Ohio 44131 5575 REMARQUE Le brûleur latéral d extérieur se glisse dans l ouverture et est soutenu par ses rebords latéraux Ne pas utiliser de support pour la partie inférieure Le tableau de dimensions et l illustration ci dessous comprennent les dimensions de l ouverture à découper et les valeurs minimales de dégagements de séparation pour tous les produits d...

Страница 22: ... Dimensions de l ouverture à découper Gril encastré Taille du gril Dimension C Dimension D Dimension E 27 68 6 cm 29 75 2 cm 10 27 3 cm 22 58 1 cm 36 91 4 cm 38 98 1 cm 10 27 3 cm 22 58 1 cm 48 121 9 cm 50 128 6 cm 10 27 3 cm 22 58 1 cm Dimensions de l ouverture à découper Gril encastré avec housse d isolation Taille du gril Dimension C Dimension D Dimension E 27 68 6 cm 33 83 8 cm 11 29 8 cm 24 6...

Страница 23: ... 2 5 cm max de la partie inférieure de l enceinte avec partie inférieure de l ouverture de 10 po 64 5 cm minimum Aucune ouverture d aération ne doit être obstruée Chaque ouverture doit comporter une largeur de 0 32 cm minimum Dimensions de l ouverture à découper Portes d accès encastrées Taille de la porte Dimension F Dimension L 18 45 7 cm 16 41 1 cm 1 3 8 cm 27 68 6 cm 25 63 8 cm 1 3 8 cm 30 76 ...

Страница 24: ...nal Fuel Gas Code ANSI Z223 1 ou CAN CGA B149 1 IMPORTANT Le brûleur latéral doit être raccordé à une source d alimentation en gaz régulée Le type de gaz utilisable est indiqué sur la plaque signalétique de l appareil si celui ci ne correspond pas au type de gaz disponible consulter le fournisseur de gaz local Conversion pour changement de gaz Ne pas entreprendre de convertir le brûleur latéral po...

Страница 25: ...ion de gaz à une pression égale ou inférieure à lb po 3 5 kPa Gaz naturel Les brûleurs latéraux sont configurés pour l alimentation au gaz naturel Leur conception est homologuée par CSA International pour l alimentation au gaz de pétrole liquéfié propane ou butane après conversion appropriée Les brûleurs latéraux sont configurés pour l alimentation au gaz naturel ils comportent un détendeur avec u...

Страница 26: ...rûleur latéral Utiliser un composé d étanchéité des tuyauteries sur tous les filets mâles non évasés Veiller à ne pas écraser déformer endommager le conduit de raccordement flexible lors d un déplacement du brûleur latéral 4 Ouvrir le robinet d arrêt manuel sur la canalisation de gaz Le robinet est ouvert lorsque la manette est parallèle à la canalisation 5 Vérifier tous les raccordements en les b...

Страница 27: ...rmique minimum Si le brûleur s éteint lorsqu il est réglé pour le débit thermique minimum position LO on doit effectuer un réglage du débit thermique minimum 1 Allumer le brûleur et tourner le bouton de commande au réglage le plus faible puis retirer le bouton 2 Immobiliser la tige de réglage du robinet avec une pince et insérer un petit tournevis à lame plate dans la tige creuse 3 Observer les fl...

Страница 28: ... crépitement généré par l allumeur Lorsque le brûleur est allumé lâcher le bouton tourner le bouton de commande au réglage désiré 6 Répéter ce processus pour chaque brûleur à allumer IMPORTANT Si un brûleur ne s allume pas immédiatement ramener le bouton du robinet à la position d arrêt OFF et attendre 5 minutes avant une nouvelle tentative Allumage manuel du brûleur latéral 1 Retirer le capot de ...

Страница 29: ... pour acier inoxydable sur toutes les zones non dédiées à la cuisson avant la première utilisation Appliquer de nouveau après chaque nettoyage pour éviter les dommages permanents à la surface Le nettoyage doit toujours être suivi d un rinçage à l eau tiède propre Essuyer complètement la surface à l aide d un chiffon doux Pour les taches tenaces ou la graisse incrustée utiliser le produit dégraissa...

Страница 30: ...HENAID Pour localiser des pièces spécifiées par l usine dans votre région nous appeler ou contacter le centre de service désigné KitchenAid le plus proche Accessoires Produit dégraissant pour gril de barbecue et de cuisine Commander la pièce n 31617 Nettoyant et poli pour acier inoxydable KitchenAid Commander la pièce n 4396920 Chiffons pour acier inoxydable KitchenAid Commander la pièce n 8212510...

Страница 31: ...autres que l usage unifamilial normal ou lorsque les instructions d installation et ou les instructions de l opérateur ou de l utilisateur fournies ne sont pas respectées 4 Les dommages imputables à accident modification usage impropre ou abusif incendie inondation actes de Dieu installation fautive ou installation non conforme aux codes d électricité ou de plomberie ou l utilisation de pièces con...

Страница 32: ...otre gros appareil ménager pour mieux vous aider à obtenir assistance ou service en cas de besoin Vous devrez connaître le numéro de modèle et le numéro de série au complet Vous trouverez ces renseignements sur la plaque signalétique située sur le produit Nom du marchand ______________________________________________ Adresse ________________________________________________________ Numéro de téléph...

Отзывы: