4-
REMOVING THE CAVITY LAMP HOLDER,
THE STIRRER MOTOR, AND CAVITY THERMOSTAT #
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug microwave oven or disconnect
power.
2. Remove the microwave oven from its
mounting location (see page 2-4 for the
procedure and do procedure in reverse).
3. Remove the cabinet from the oven (see
page 4-4 for the procedure).
WARNING
4. Remove the hood exhaust fan motor (see
page 4-8 for the procedure).
5. Remove the two top subpanel screws from
the rear panel (see the top-right photo).
6. Lift the right-rear air guide and unhook it
from the right-front air guide.
7. Pull the power supply cord off the right-
front air guide.
8. Remove the five indicated screws from
the top subpanel. Remove the left air grille
and the wire grille from the oven after the
screws are removed.
Continued on the next page.
Stirrer Motor Cavity Therm. #2 Cavity Lamp Holder
Top Subpanel
Rear Screws
Top Subpanel Right Rear Air Guide
5 Top Subpanel Screws
Left Air Grille
Wire Grille
Power Supply Cord
Right Front
Air Guide