Страница 1: ...ctions for local electrical inspector suse Part No 4329225 9763381 Quick Reference Table of Contents Pages Before you start Electrical requirements Product dimensions Cabinet dimensions Countertop cutout dimensions Vent system requirements Interior mounted vent motor _ installation steps Vent system requirements Exterior mounted vent motor _ _ Installation steps Use and Care information Accessorie...

Страница 2: ... Setups ANSI A225 1 NFPA 501A or latest edition or with local codes All openings in the wall or floor where retractable downdraft vent is to be installed must be sealed Electrical ground is required See Electrical requirements page 3 When installing downdraft vent the cabinet drawer will need to be removed and the drawer front installed permanently to cabinet NOTE Downdraft vent is installed direc...

Страница 3: ...codes and ordinances WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING installation work and electrical wiring must be done by qualified person s in accordance with all applicable Codes and Standards including fire related construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment...

Страница 4: ...er s instructions for cooktop cutout depth and width Use dimensions for vent system cutout location that applies to your installation 17 3 16 43 7 cm 17 9 16 44 6 cm all cutouts are for 3 1 4 x 10 8 3 cmx 25 4 cm vent system Locate power supply junction box at lower right hand rear corner of cabinet centerline of cooktop cutout Vent system cutout dimensions for internal blower models only Exterior...

Страница 5: ...30XHS GZ7730XGS GZ7930XGS GZ7930XHS A B C 29 27 1 2 19 5_ 73 7cm 69 9cm 49 8cm 29 1_ 27 1 2 20 1_ 74 9cm 69 9cm 52 1cm 28 7 8 27 1 2 19 73 3cm 69 9cm 48 3cm 29 27 1 2 19 5 8 73 7cm 69 9cm 49 8cm 29 1 2 27 1 2 20 1 2 74 9cm 69 9cm 52 1cm 28 7 8 27 1 2 19 73 3cm 69 9cm 48 3cm D 2 1 8 5 4cm 2 1 8 5 4cm 2 1 2 6 4cm 2 1 8 5 4cm 2 5 1cm 2 1 2 6 4cm E 1 3 4 4 4 cm 2 5 1 cm 3 3 8 8 6 cm 1 3 4 4 4 cm 5 1 c...

Страница 6: ...round metal vent wall 12 30 5 cm minimum 6 15 2 cm round PVC i coupling 6 15 2 cm Tightly pack round 90 gravel or sand PVC sewer completely pipe elbow around pipe 6 15 2 cm transition round PVC 6 15 2 cm sewer pipe round metal vent 15 2 cm round PVC oupling slab round PVC sewer pipe 6 15 2 cm round 90 PVC sewer pipe elbow Built in cabinet locations down vent rear vent left vent right vent Optional...

Страница 7: ...Carefully insert downdraft vent into countertop cutout Two people are recommended to support the weight of the downdraft vent during lifting Check that downdraft vent is parallel to side of cutout and that mounting brackets overlap countertop level mark l 6_ Move support legs down against cabinet floor Place a level against front of downdraft vent base and adjust until downdraft vent is level vert...

Страница 8: ...vel vertically Then fasten lower support legs to cabinet floor with screws When attaching undercounter bracket to underside of countertop make sure that the screw length will not go through countertop when tightened 1 Attach one undercounter bracket on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop Attach other bracket to left side of dow...

Страница 9: ... cabinet location Built in cabinet location Roof venting L_______F 10 25 4 cm round vent Maximum length of vent system Vent Length 10 25 4 cm round 40 ft 12 2 m Vent length is given as a general reference only For a longer vent run or smaller vent system contact a qualified and trained vent installer Check with local codes for makeup air requirements if any For best performance use no more than th...

Страница 10: ...plied with exterior blower system to front of downdraft vent using 4 hex washer nuts Remove the 2 Phillips head screws attaching the wiring box cover and remove cover Remove either the back or bottom knockout and install conduit connector NOTE Power supply cable needed between exterior blower assembly and blower box is not provided Determine the location where the exterior blower box will be locat...

Страница 11: ...ox knockout and install conduit connector Feed exterior mounted vent motor wiring through conduit connector IMPORTANT Do not wire the exterior vent motor black and white wires into the wiring box Wires must be connected as shown Connect the white wires together with a twist on wire connector Connect the black wires together with a twist on connector Attach ground wire to eyelet with green ground s...

Страница 12: ...ainedintheareawhereit is started Thefiredepartmentisbeingcalled Youcanfightthefire with yourbackto anexit Thisfanis suitablefor usewith solid state speedcontrols Operating downdraft vent Push and hold for a few seconds the button on top of downdraft vent This slight delay prevents raising the vent during cleaning Retractable section of downdraft vent will rise and blower will begin to vent Turn kn...

Страница 13: ...major appliance is used for other than normal single family household use 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or use of products not approved by KitchenAid 5 Replacement parts or repair labor costs for units operated outside the United States or Canada 6 Pickup and del...

Страница 14: ...s to parts or systems resulting from unauthorized modifications made to the appliance 9 Expenses for travel and transportation for product service in remote locations 10 The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUS...

Страница 15: ... Customer Interaction Center telephone numbel your nearest authorized service center or Factory Service at 1 800 442 1111 For further assistance If you need further assistance you can write to Whirlpool Corporation or KitchenAid with any questions or tell us about your concerns at Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Please include a dayti...