5-3
Refer to page 4-8 for the procedure for servic-
ing the wax motor.
1.
Unplug dishwasher or disconnect power.
2.
Disconnect one of the wires from the wax
motor terminals.
3.
Set the ohmmeter to the R x 100 scale.
4.
Touch the ohmmeter test leads to the wax
motor terminals. The meter should indi-
cate between 600 and 1800
Ω
.
WAX MOTOR
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Refer to page 4-13 for the procedure for servic-
ing the water inlet valve.
1.
Unplug dishwasher or disconnect power.
2.
Disconnect one of the wires from the water
inlet valve solenoid terminals.
3.
Set the ohmmeter to the R x 100 scale.
4.
Touch the ohmmeter test leads to the
water inlet valve solenoid terminals. The
meter should indicate between 890 and
1090
Ω
.
WATER INLET VALVE SOLENOID