22
9. Reinstall the cap onto the regulator.
To Convert Standard Surface Burners
1. Remove burner cap.
2. Using a T20 TORX
®
screwdriver, remove the burner base.
3. Apply masking tape to the end of a
7
mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out. Set gas orifice
spud aside.
4. Natural gas orifice spuds are stamped with a number on the
side. Replace the LP gas orifice spud with the correct Natural
gas orifice spud.
Refer to the following chart for the correct Natural gas orifice
spud placement.
Natural Gas Orifice Spud Chart for Standard Surface Burners
5. Place LP gas orifice spuds in plastic parts bag for future use
and keep with the package containing literature.
6. Replace burner cap.
7. Repeat steps 1-6 for the remaining burners, except for the
TripleTier
®
Flame burner (on some models). See “To Convert
TripleTier
®
Flame Burners” section.
To Convert TripleTier
®
Flame Burner (on some models)
1. Remove burner cap.
2. Remove the burner head using a size T20 TORX
®
screwdriver.
3. Remove the plate on the external gas orifice spud.
IMPORTANT: The TripleTier
®
Flame burner has 2 gas orifice
spuds. Be sure to change the external gas orifice spud
located under the plate.
4. Apply masking tape to the end of a
7
mm nut driver to help
hold the internal gas orifice spud in the nut driver while
changing it. Press nut driver down onto the internal gas
orifice spud and remove by turning it counterclockwise and
lifting out. Set internal gas orifice spud aside.
5. Use a 7 mm combination wrench to remove the external
orifice spud. Turn counterclockwise remove. Set external gas
orifice spud aside.
A. Access cap
B. Gasket
C. Gas pressure regulator
D. Spring retainer
NAT position
E. Spring retainer
LP position
A. Igniter electrode
B. Gas tube opening
C. Burner cap
D. Burner base
A. Stamped number
Burner Location
Burner Rating
Size
Right front
Left front
Right rear
Left rear
6,000 Btu/h
14,000 Btu/h
12,500 Btu/h
6,000 Btu/h
1.10 mm
1.70 mm
1.61 mm
1.10 mm
A
B
C
D
E
A
B
C
D
XXX
A
A. Burner caps
B. Burner heads
C. External gas orifice spud access plate
D. Internal gas orifice spud
A. Plate
B. External gas orifice spud
C. Internal gas orifice spud
A
B
C
D
A
B
C