If removing the cooktop is necessary
for cleaning or maintenance:

1. Disconnect electrical supply.
2. Disconnect vent duct system.
3. Lift cooktop out of countertop to

complete cleaning or maintenance.

After cleaning and maintenance:

1. Reinstall cooktop in cutout.
2. Check that front edge of cooktop is

parallel to front edge of countertop.

3. Connect vent duct system.
4. Connect electrical supply.

Cooktop removal

If cooktop does not
operate:

Check that circuit breaker is not

tripped or the house fuse blown.

Check that wire connections are intact.

See Use and Care Guide for
troubleshooting list.

If you need
assistance:

The KitchenAid Consumer Assistance
Center is open 24 hours a day, 7 days a
week. Call 1-(800) 422-1230. The call is
free within the continental United States.
In Canada, call 1-(800) 461-5681 for
English and 1-(800) 461-5703 for French.
Or visit our web site at
www.kitchenaid.com.

When you call, you will need the cooktop
model number and serial number. Both
numbers can be found on the
model/serial rating plate located on the
bottom of the cooktop.

If you need service:

Consult your Use & Care Guide.

In the event that your KitchenAid
appliance should need service, call the
dealer from whom you purchased the
appliance or a KitchenAid-designated
service company. A KitchenAid-
designated service company is listed in
the Yellow Pages of your telephone
directory under “Appliances —
Household — Major — Service and
Repair.” 

Содержание 8285364

Страница 1: ...nd serial numbers before installing cooktop Both numbers are on the model serial rating plate located on the bottom of the cooktop Model ___________________________ Serial ___________________________ Questions regarding features operation performance parts or service Call 1 800 422 1230 or visit our web site at www kitchenaid com IMPORTANT Read and save these instructions 30 76 2 cm and 36 91 4 cm...

Страница 2: ...ion is correct and to make sure the electrical installation follows the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances tape measure hand or electric drill metal snips duct tape pliers gloves safety glasses caulking gun with weatherproof caulking Phillips screwdriver ...

Страница 3: ...ration Decorative laminate Chamfer all exposed edges to prevent chipping laminate Cut radius corners and file to smooth edges and to prevent cracking 2 5 1 cm minimum space to front edge of countertop Install rear wall junction box in shaded area Darker shaded area is preferred Select required duct cutout see Page 4 for exhaust duct cutout location Countertop must be supported within 3 7 6 cm of c...

Страница 4: ...ransition elbow 3 1 4 x 10 8 3 x 25 4 cm transition elbow inside wall to roof or overhang outside wall cabinet directly outside peninsula or island peninsula between floor joists cabinet toe space to outside The blower housing is set to vent straight out the back from the cooktop To vent down left or right see Installation Step 2 Page 6 This downdraft cooktop is rated at 60 feet 18 3 m of straight...

Страница 5: ... 5 ft 90 elbow 1 5 m transition to round 3 1 4 x 10 8 3 x 25 4 cm to 9 ft 6 15 2 cm 90 elbow 2 7 m 3 1 4 x 10 8 3 x 25 4 cm to 4 5 ft 6 15 2 cm 1 4 m transition to flat 6 15 2 cm to 3 1 4 x 10 5 ft 8 3 x 25 4 cm 90 elbow 1 5 m 6 15 2 cm to 1 ft 3 1 4 x 10 8 3 x 25 4 cm 30 5 cm wall cap 3 1 4 x 10 8 3 x 25 4 cm 0 ft 0 cm 6 15 2 cm round 0 ft 0 cm roof cap 10 x 10 25 4 X 25 4 cm 0 ft 0 cm thermal br...

Страница 6: ...and all local codes and ordinances Wire sizes and connections must conform with the rating of the cooktop Copies of the standard listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Canadian Standard Association 178 Rexdale Boulevard Etobicoke Ontario M9W 1R3 The wiring diagram is located on the bottom of the cooktop Twist on connectors and ...

Страница 7: ...ire system If local codes PERMIT connecting cooktop ground conductor to neutral junction box wire three wire system Figure 1 power supply cable from cooktop junction box U L listed conduit connector red wires white wire black wires green ground appliance cable wire green or bare ground wire Figure 2 junction box red wires white wire cable from fused disconnect or circuit breaker box black wires po...

Страница 8: ...at wire connections are intact See Use and Care Guide for troubleshooting list If you need assistance The KitchenAid Consumer Assistance Center is open 24 hours a day 7 days a week Call 1 800 422 1230 The call is free within the continental United States In Canada call 1 800 461 5681 for English and 1 800 461 5703 for French Or visit our web site at www kitchenaid com When you call you will need t...

Страница 9: ...uméros de modèle et de série avant d installer la table de cuisson On trouve ces deux numéros sur la plaque signalétique située sur le fond de la caisse de la table de cuisson N de modèle N de série Pour des questions concernant les caractéristiques le fonctionnement la performance les pièces accessoires ou le service composer le 1 800 422 1230 ou consulter www kitchenaid com IMPORTANT Lire et con...

Страница 10: ...alisations qui peuvent s y trouver Le conduit d évacuation associé à un ventilateur doit toujours décharger l air à l extérieur AVERTISSEMENT Pour réduire le risque d incendie utiliser uniquement des conduits métalliques La table de cuisson à aspiration vers le bas n est pas approuvée pour utilisation dans les habitations mobiles Des exemplaires des normes indiquées peuvent être obtenus aux adress...

Страница 11: ...lacard inférieur de 76 2 cm 30 po profondeur de placard inférieur de 61 cm 24 po profondeur de dessus de comptoir de 63 5 cm 25 po Les dimensions de l ouverture dans le comptoir indiquées doivent être utilisées Les dimensions données sont les dégagements minimums et fournissent le dégagement requis de 0 cm 0 po Nouvelles installations Suivre les dimensions minimales données 12 7 cm 5 po 43 2 cm 17...

Страница 12: ...4 4 cm 9 5 8 po table de cuission 76 2 cm 30 po 33 8 cm 13 5 16 po table de cuission 91 4 cm 36 po trou de 24 8 cm 9 3 4 po à l arrière ou sur le côté du placard Méthodes d évacuation placard de mur intérieur 8 3 x 25 4 cm 3 1 4 x 10 po coude de transition 8 3 x 25 4 cm 3 1 4 x 10 po coude de transition à l intérieur du mur jusqu au toit ou surplomb placard de mur extérieur directement vers l exté...

Страница 13: ...le calcul de la longueur maximale du système d évacuation Il faut utiliser une bouche de décharge à travers le mur ou le toit convenable option circuit d évacuation installé sous une dalle de béton dans une fosse de fenêtre coude de 90 15 2 cm 6 po coude de 90 15 2 cm 6 po bouche de décharge murale 15 2 cm 6 po 61 cm 2 pi 1 2 m 4 pi Remarque On déconseille l emploi d un conduit d évacuation flexib...

Страница 14: ...t obtenir des exemplaires des normes mentionnées auprès de National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Association canadienne de normalisation CSA 178 Rexdale Boulevard Etobicoke Ontario M9W 1R3 Le schéma de câblage se trouve à la base de la table de cuisson Les connecteurs vissables et les connecteurs de conduit 12 7 mm 1 2 po homologation UL ne sont pas four...

Страница 15: ...terre de la table de cuisson au fil neutre blanc de la boîte de connexion système à trois fils Figure 1 boîte de connexion connecteur de conduit homologué U L fils rouge fil blanc fils noirs fil de liaison à la terre du câble d alimentation de l appareil fil de liaison à la terre nu ou vert Figure 2 boîte de connexion fils rouge fil blanc câble du sélectionneur à fusible ou du boîtier des disjonct...

Страница 16: ...lisation et d entretien pour la liste de dépannage Si vous avez besoin d assistance Le Centre d assistance à la clientèle KitchenAid est accessible 24 heures par jour 7 jours par semaine Téléphoner au 1 800 422 1230 La communication est gratuite dans les limites du territoire continental des États Unis Au Canada composer pour l anglais 1 800 461 5681 ou pour le francais 1 800 461 5703 Ou visitez n...