Electrical Connection - U.S.A. Only
1. Disconnect power.
2. Remove the terminal block cover screws and disengage
mounting tabs to remove terminal block cover from back of
range.
3. Add power supply cord strain relief.
■
Assemble a UL listed strain relief in the opening.
■
Tighten strain relief screw against the power supply cord.
4. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
30" (76.2 cm) and 36" (91.4 cm) Models
48" (121.9 cm) Models
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 50 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A. Phillips head screws
B. Terminal block cover
C. Two mounting tabs at bottom
A. UL listed strain relief
A
B
C
A
If your home has:
And you will be
connecting to:
Go to Section:
4-wire receptacle
(NEMA type 14-50R)
A UL listed,
250-volt
minimum,
40- or 50-amp,
range power
supply cord
4-wire connection:
Power supply cord
3-wire receptacle
(NEMA type 10-50R)
A UL listed,
250-volt
minimum,
40- or 50-amp,
range power
supply cord
3-wire connection:
Power supply cord