•  Install the selected fuse to the fuse holder. 
•  Turn Disconnect Switch to ON position. 

 

Connect unit with provided accessories (Battery Clips or Lighter Plug Cable) 
Using the Lighter Plug Cable: (SW1204 series and MW1204 series only) 

CAUTION: Due to the limitations of the 12V lighter plug socket in vehicles, the unit should be 
used with the DC cable with lighter plug only to supply AC power to products that require 
150W (120VAC/1.3 A or 230V/0.65A) or less. If the appliance requires more than 150W, use 
the DC Battery Cable Clips for battery connection. 
•  Attach the red ring-type connector to the positive (+) DC terminal (red) on the power 

inverter and connect the black ring type connector to the negative (-) DC terminal (black) 
on the Power inverter. 

•  Tighten the nut on each DC terminal. 
•  Insert the light plug of this cable to the fused 12V lighter plug socket. 
•  Unit is ready for use. 

Using the Battery Clips Cable: 

CAUTION: Please be sure all the connections are tight before the use of the unit. 
•  Attach the red ring-type connector to the positive (+) DC terminal (red) on the power 

inverter and connect the black ring type connector to the negative (-) DC terminal (black) 
on the Power inverter. 

•  Attach the negative (black) clip to the negative (-) battery terminal. 
•  Attach the positive (red) clip to the fuse or circuitry breaker of the 12V battery bank as 

indicated on ‘Typical Wiring block diagram of the Power Inverter’ on page 5. 

•  Unit is ready for use. 

 
Test the Power Inverter: 
•  Turn unit on by switching the On/Off button to ‘ON’ or ‘Power Save OFF’ position on the unit. 

The ‘Power’ light turns on indicating the Power Inverter is ON. AC output is now available. 

•  Plug in a small AC load like a 40W table lamp or small appliance to the AC socket to verify 

AC is available. 

•  The unit is successfully installed and functioning properly. 
 
Test the GFCI Monthly (for unit come with GFCI socket only): 
•  Turn unit on and plug a small AC load (40W light bulb) to the GFCI socket. 
•  Check the AC Load is ON. 
•  Press the ‘TEST’ button on the GFCI socket, the socket will trip and the AC load turns OFF.  
•  Press the ‘RESET’ button to reset the GFCI and the AC Load will turns back ON. 
•  GFCI is functioning properly. 

 

4. UNIT 

OPERATION 

WARNING: RISK OF EQUIPMENT DAMAGE 
•  Do not connect an AC power source like utility power or generator to the AC outlets of the 

inverter. 

•  For MW series, do not plug surge-protected power bars to the AC Output socket of the unit 

Some surge protected components on the surge-protected power bar may not like the 
modified sinewave output generate by the MW series inverter. 

For SW Series with Power Save Mode: 

Turn on the unit in ‘Power Save OFF’ mode 
•  Toggle the 3 position switch to ‘Power Save OFF’ position (bottom) to turn unit ON in 

normal operation. 

•  Continuous AC Output is available at the AC output socket. Green ‘Power’ indicator will 

turn ON and5V USB is available. 

•  Toggle the switch to middle position to turn unit off. ‘Power’ indicator will turn off. 
Turn on the unit in ‘Power Save ON’ mode 
•  Toggle the 3 position switch to ‘Power Save ON’ position to turn unit ON with Power Save 

feature. Green ‘Power’ indicator will turn ON, 5V USB is available. 

•  If no load or < 10W load is connected to the AC output of the unit, the RED ‘Fault’ LED will 

flash, this indicates ‘Power Save’ mode is ON. The unit will provide few AC cycle for every 
5 seconds.  

•  If >10W AC load is connected to the unit, the RED ‘Fault’ indicator will turn OFF indicating 

that continuous AC output is provided. 
Note: This special ‘Power Save’ mode is designed to let the unit run in standby mode and 
check for any AC load with more than 10W every 5 seconds. If load connected is >10W, a 
continuous AC Output is provided. The unit will automatically return to standby mode when 
AC load connected drops to < 5W. 

For MW Series or SW series without Power Save Mode: 

Turn ON and OFF the unit 

  Toggle the On/Off switch to ‘ON’ position to turn unit ON. 

  ‘Power’ indicator will turn ON indicates AC Output power is available. 

  Toggle the On/Off switch to ‘Off’ position to turn unit off. ‘Power’ indicator will turn off. 

 
Understanding the LED indicators 
‘Power’ Indicator: Illuminated indicates unit is ON. 
‘Fault’ indicator:  

 

Illuminated continuously indicates fault was detected. Unit has shutdown. To reset unit, 
remove the fault condition and reset unit by using the toggle switch and turn unit off and on 
again. 
For SW series with ‘Power Save Mode’ function, ‘Fault’ indicator flashing indicates ‘Power 
Save’ mode is ON and power consumption on AC load is <10W. 

 
 
 

Understanding the Fan Operation 
The fan on the unit is load activated. It will automatically turn on when AC output power exceed 
the pre-set values (~ 200W). 
 
AC Load on Power Inverter 
Although the Power Inverter can provide high surge power up to two times the rated output 
power, some appliances may still trigger on the inverter protection system during start up or 
surge period. A higher power inverter is required for those appliances. 
Important: 
For Modified Sinewave Inverter MW series, 

some appliances like speed controllers 

found in some fans, power tools and some power tools’ AC charger may not like the modified 
sine wave generate by the inverter, those appliances may not work or may be damaged if they 
are connected to the inverter. If you are unsure about powering any device with the inverter, 
contact the manufacturer of the device. 

 
Estimated Run time on Load 
Following run time is an estimate based on using a 12V-120AH battery bank for 12V system 
and 24V-60AH battery bank 24V system. Actual runtime may vary. 

Load 

Consumption 

Estimate Run time 

Cordless Phone 

5W 

150 hrs 

Clock / Radio 

8W 

100 hrs 

Table Lamp 

40W /  60W 

27 hrs/ 18 hrs 

Small Freezer (8.8 cu. ft.) 

80W 

15 hrs 

20” LCD TV 

100W 

11.5 hrs 

Flooded Light 

500W 

1 hr 

Sump Pump (1/2 hp) 

350W 

Not applicable (surge too high) 

 

5. TROUBLESHOOTING 

Problem Symptom 

Solution 

The unit is off 

Turn unit ON using the toggle switch 

No AC output and 
‘Power’ LED is OFF 

No power to 
inverter 

Check fuse or the Disconnect switch (if 
installed) is either blown or turned OFF 

No AC output. ‘Fault’ 
indicator is ON 

Unit has detected 
fault and has 
shutdown 

Verify the fault condition (the load 
connected may be too high). Make 
correction and reset unit. 

‘Fault’ indicator is 
Flashing. AC Load 
connected is turning 
ON and OFF (For 
unit with “Power 
Save’ Feature only 

‘Power Save’ 
mode is in use and 
the AC load 
connected is 
<10W 

Unit is normal.  
Power consumption on AC load 
connected is <10W, switch unit to 
‘Power Save OFF’ mode to have a 
continuous output or increase the AC 
load to >10W. 

 

6. SPECIFICATIONS 

Note: Specifications are subject to change without notices. 

Specifications MW1204

SW1204

MW1204i

SW1204i

SW2405

SW2405i

Inverter 
AC Output Power 

400 Watt 

500 Watt 

AC Output Current 

3.33A 

1.74A 

4.17A 

2.17A 

AC Surge Power 

800 Watt 

AC Output Voltage 

120Vac 

60Hz 

230Vac 

50Hz 

120Vac 

60Hz 

230Vac 

50Hz 

AC Output Waveform

True Sinewave (<3% THD) 

DC Input Voltage 

12.5 VDC 

25.0 VDC 

No 

Load 

Current 

<0.3A N/A <0.3A N/A 

N/A 

No Load Current 
(Power Save OFF) 

N/A 

< 0.8 A

N/A 

< 0.8 A

<0.5 A 

No Load Current 
(Power Save ON) 

N/A 

< 0.1 A

N/A 

< 0.1A 

<0.1 A 

DC Operating Range

10.5 – 15.75VDC 

21.0 – 31.0 VDC 

Under Voltage Alarm

11.0 VDC 

22.4 VDC 

UV Shutdown 

10.5 VDC 

21.0 VDC 

UV Recovery 

12.0 VDC 

23.6 VDC 

OV Shutdown 

15.75 VDC 

31.0 VDC 

AC Output Socket 

NEMA 

5-15 

NEMA 

5-15 

(GFCI) 

EU, AU, UK 

NEMA 

5-15 

(GFCI) 

EU,  
AU,  

UK 

DC Output 
USB Output (5V) 

N/A 

 2.1A 

N/A 

2.1A 

2.1A 

2.1A 

Safety and Environmental 
Agency Markings 

cETLus *

cETLus *

N/A 

CE 

cETLus *

CE 

Operating Temp. 

0

Ԩ

 to 40

Ԩ

 (32

Ԭ

 to 104

Ԭ

Storage Temp. 

-20

Ԩ

 to 60

Ԩ

 (-4

Ԭ

 to 140

Ԭ

Relative Humidity 

5 - 90% noncondensing 

Operating Altitude 

Up to 6,560ft (2000 m) above sea level 

Weights and Dimensions 
Weights 

0.73 kg 

1.73 kg 

0.80 kg

1.73 kg

1.73 kg 

Dimensions 
(LxWxH) 

MW1204: 152 x 101 x 51 mm,  
MW1204i: 158 x 105 x 67 mm 

SW Series:  312 x 175 x 87mm 

The product is conforms to UL STD.458 and certified to CSA STD. C22.2 No.107.1 

 

7. WARRANTY 

One Year Limited Warranty 
The limited warranty program is the only one that applies to this unit, and it sets forth all the 
responsibilities of KISAE. There is no other warranty, other than those described herein. Any 
implied warranty of merchantability of fitness for a particular purpose on this unit is limited in 
duration to the duration of this warranty. 
This unit is warranted, to the original purchaser only, to be free of defects in materials and 
workmanship for one year from the date of purchase without additional charge. The warranty 
does not extend to subsequent purchasers or users. 
Manufacturer will not be responsible for any amount of damage in excess of the retail 
purchase price of the unit under any circumstances. Incidental and consequential damages are 
specifically excluded from coverage under this warranty. 
This unit is not intended for commercial use. This warranty does not apply to damage to units 
from misuse or incorrect installation/connection. Misuse includes wiring or connecting to 
improper polarity power sources. 
 
Return/Repair Policy: 
If you are experiencing any problems with your unit, please contact our customer service 
department [email protected] or Phone 

1-877-897-5778

 before returning product to 

retail store. After speaking to a customer service representative, if products are deemed non-
working or malfunctioning, the product may be returned to the purchasing store within 30 days 
of original purchase. Any defective unit that is returned to manufacturer within 30 days of the 
date of purchase will be replaced free of charge. If such a unit is returned more than 30 days 
but less than one year from the purchase date, manufacturer will repair the unit or, at its option, 
replace it, free of charge. If the unit is repaired, new or reconditioned replacement parts may 
be used, at manufacturer’s option. A unit may be replaced with a new or reconditioned unit of 
the same or comparable design. The repaired or replaced unit will then be warranted under 
these terms for the remainder of the warranty period. The customer is responsible for the 
shipping charges on all returned items. 
 
Limitations: 
This warranty does not cover accessories, such as adapters and batteries, damage or defects 
result from normal wear and tear (including chips, scratches, abrasions, discoloration or fading 
due to usage or exposure to sunlight), accidents, damage during shipping to our service facility, 
alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for 
care and maintenance, fire and flood. 
If your problem is not covered by his warranty, call our Customer Service Department 
[email protected] or 

1-877-897-5778 

for general information if applicable. 

Отзывы: