![Kisae 3000W - 120V Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/kisae/3000w-120v/3000w-120v_owners-manual_1972249008.webp)
Page 8
Remote Display Connection:
•
The Remote Display on the unit is detachable. To install the remote in a different location, the
provided 6 pin standard RJ12 cable is used.
•
Remove the 2 screws at the front of the Display Panel and disconnect the small RJ12 cable from
the unit.
•
Install the RJ12 cable in your desired location.
•
Connect one end of the RJ12 cable to the unit and the other end of the cable to the Display
Panel. Please note polarity.
Test the Inverter connection:
•
Switch DC disconnect switch to ON to provide battery power to the unit.
•
‘Status’ LED turns green indicates the unit is running and AC output is available on all four AC
output ports.
•
‘Display’ LED turns on and the digital display will alternatively shows battery voltage in Volts (e.g.
‘12.5’ means 12.5V) and total AC Output power in KW.
•
5V USB is now available.
•
Plug in a small AC load like a 40W table lamp or small appliance to the AC socket to verify AC is
available.
•
The unit is successfully installed and functioning properly.
4. UNIT
OPERATION
Understanding the Detachable Display Function:
Understanding the Power and Select push button function during normal operation
A beep sound will occur every time when the ‘Power’ or ‘Select’ button is triggered.
‘Power’ button function:
•
Turns inverter On/Off. Press and hold for 1 second to turn unit ON or OFF.
‘Select’ button function:
•
Check unit setting: Press once to check or verify unit’s present set functions
Understanding the Error Code
Code Condition
Corrective
Action
E01
Input battery voltage is too low and
unit has shutdown
Recharge battery immediately and
restart unit
E02
Input battery voltage is too high
and unit has shutdown
Check battery voltage or determine if
any external charger is connected to the
battery bank
E03
AC output is overloaded or short
circuited and unit has shutdown
Check load connected to the output.
Reduce load and restart the unit
E04
Internal temperature is too high
and unit has shutdown
Turn unit off and wait for 15 minutes
before restarting. Check if any object
has blocked the air flow of the unit
E05
Input battery voltage is low and
warning occurs
Recharge battery as unit will shutdown
shortly
Status
LED
Display
LED
Display
Function/Status
Green
‘12.5’
Display shows battery
voltage in DC volts
Green
Amber
‘0.80’
Display shows output
power in KW (e.g. ‘0.80’
means 0.80KW=800W)
Red
(solid)
OFF E01-E07
Unit has shutdown.
Display shows error code
(See error code chart
below)