on the Power inverter. 

•  Attach the negative (black) clip to the negative (-) battery terminal. 
•  Attach the positive (red) clip to the fuse or circuit breaker of the 12V battery bank as 

indicated on ‘Installation Preparation’ diagram. 

•  Unit is ready for use. 

 
Connect unit for Permanent use (cable not provided) 

•  Unit is for indoor use only, choose an appropriate mounting location. 
•  Orientation: Unit can be mounted in any direction. 
•  Use mounting template below to mark the positions of the mounting screws. Drill the 4 

mounting holes and place the inverter in position and fasten the inverter to the mounting 
surface. 

 

•  Use of low resistance wire is required for all the DC connections between the inverter and 

the battery bank. 

•  Uses minimum #8 AWG wire with maximum cable length of 5 feet for the Inverter system. 
•  Connect one end of the negative DC input cable to the Power Inverter DC negative (black) 

M6 terminal. 

•  Connect the other end of the negative DC input cable to the battery negative terminal. 
•  Make sure the Disconnect Switch is in the OFF position. 
•  Connect one end of the positive DC input cable to the Inverter DC positive (red) M6 

terminal. 

•  Connect the other end of the positive DC input cable to one of the terminals of the 

Disconnect Switch. 

•  Connect a DC input cable between the other terminal of the Disconnect Switch and one 

side of the terminal of the fuse holder. 

•  Connect a DC input cable between the other terminal of the fuse holder and the battery 

positive terminal. 

•  Install the selected fuse to the fuse holder. 
•  Turn Disconnect Switch to ON position. 

 

Remote Switch (optional) Connection: 

•  The unit comes with a Remote port and an optional KISAE ‘Remote Switch’ accessory 

(RM1201-00) can be used to turn unit On and OFF remotely. To install the ‘Remote 
Switch
’, just connect the switch’s RJ12 plug to the RJ12 ‘Remote’ port located at the 
Front AC panel of the Power inverter. Please note polarity when connecting the plug.  

•  The Power On/Off push button on the remote share the same function as the green 

On/Off’ button on the main unit.  

 
Use of the Ignition Start Function on unit: 

• 

An ‘Ignition Start’ port is located at the Front AC Panel of the unit using a ¼” width spade 
terminal. This port is used for turning the unit On and OFF using a +12V signal. An 
insulated female connector is required to connect to the port.  

 

• 

Connecting to +12V will turn ON the unit and removing the +12V signal will turn OFF the 
unit.  

 

 
 Power Inverter Test after installation: 

•  Press and hold the green ‘On/Off’ button on the unit to turn ON the unit. 
•  Check that the ‘Status’ indicator turns to solid green. 
•  Plug in a small AC load like a 40W table lamp or small appliance to the AC socket to verify 

AC is available. 

•  The unit is successfully installed and functioning properly. 

 

4. UNIT OPERATION 

WARNING: RISK OF EQUIPMENT DAMAGE 

Do not connect an AC power source like utility power or generator to the AC outlets of the 
unit. 

Turn ON and OFF the unit 

•  Press and hold the green ‘On/Off’ button for about a second to turn ON the unit. 
• ‘Status’ indicator in green color indicates AC Output power is available. 

• 

Press again the green ‘On/Off’ button to turn OFF the unit and the ‘Status’ indicator will 
turn off.

 

 

 
 
 

Understanding the ‘Status’ indicator and the unit warning and fault alarm 

Status’ indicator:  

•  Illuminated in green indicates unit is ON. AC is available at the AC Output Socket.  
•  Illuminated in green and alarm is beeping once every 2 second indicates a warning 

signal from the unit. The unit is close to shutdown with one or more of the following 
warning conditions: 

ƒ

  Over Temperature Warning: Unit internal temperature is high. Unit requires better 

ventilation. 

ƒ

  DC Under Voltage Warning: DC Input Voltage is low and is close to the unit under 

voltage shutdown limit. Checking on battery voltage or battery connection is required.  

•  Illuminated in red and alarm is beeping once every second indicates AC Output has 

shutdown due to the following conditions: 

ƒ

  Over Temperature Shutdown: Reduce the AC load connected to the unit and provide 

more ventilation to the unit. AC Output will automatically restart when the internal 
temperature cools down. 

ƒ

  DC Over Voltage Shutdown / DC Under Voltage Shutdown: Check the battery voltage. 

On the first 30 seconds, AC Output will resume when battery voltage is corrected to 
the unit operating range. If the battery voltage shutdown condition is ignored, the unit 
will latch OFF completely after 30 seconds and restart the unit using 

green ‘On/Off

 

button is required after the battery voltage is corrected. 

ƒ

  AC Output Overload Shutdown: Check AC Load connected to the unit. AC Output is 

short circuited or AC Power draw by the load is beyond the unit’s limit. The indicator 
and alarm will beep for about 30 seconds before it latched OFF completely. Restart the 
unit using the 

green ‘On/Off

 button is required after the AC Load condition is 

corrected. 

 

Understanding the Fan Operation 

The fan on the unit is AC load and internal temperature activated. It will automatically turn on 
when AC output power exceeds the pre-set values (~ 200W) and turn off when AC output 
power is reduced to 150W. It will also automatically turn on when it senses the internal 
components have reached to around 80°C (176°F) and turn off when temperature drops to 
below 60°C (140°F)

.

 

 

AC Load on Power Inverter 

Although the Power Inverter can provide high surge power up to two times the rated output 
power, some appliances may still trigger on the unit protection system during start up or 
surge period. A higher power inverter is required for those appliances. 

 

Estimated Run time on Load 

Following run time is an estimate based on using a 12V-120AH battery bank. Actual runtime 
may vary. 

Load 

Consumption 

Estimate Run time 

Cordless Phone 

5W 

150 hrs 

Clock / Radio 

8W 

100 hrs 

Table Lamp 

40W / 60W 

27 hrs / 18 hrs 

Small Freezer (8.8 cu. ft.) 

80W 

15 hrs 

20” LCD TV 

100W 

11.5 hrs 

Sump Pump (1/2 hp) 

350W 

Not applicable (surge too high) 

 

5. TROUBLESHOOTING 

Problem Symptom 

Solution 

The unit is off 

Turn unit ON 

No AC output and 
Status’ light is 
OFF 

No power to inverter

Check fuse or the Disconnect switch (if 
installed) is either blown or turned OFF 

Status’ indicator 
is in green (alarm 
beeps every 2 
seconds) 

Unit has detected a 
warning and is going 
to shutdown 

Verify the warning condition and make 
adjustment. See “Understanding the 
‘Status’ indicator and the unit warning 
and fault alarm
 in this manual 

Status’ indicator 
is in red (alarm 
beeps every 
second) 

AC Output has 
shutdown 

Check unit condition and make correction. 
See “Understanding the ‘Status’ 
indicator and the unit warning and fault 
alarm
” in this manual 

 

6. SPECIFICATIONS 

Note: Specifications are subject to change without notices. 

Specifications SL1204 

SL1204i 

Inverter 

  AC Output Power 

400 Watt 

  AC Output Current 

3.33A 

1.74A 

  AC Surge Power 

800 Watt 

  AC Output Voltage 

120Vac / 60Hz 

230Vac / 50Hz 

  AC Output Waveform 

True Sinewave (<5% THD) 

  DC Input Voltage 

12.5 VDC 

  No Load Current    

< 0.8 A 

  DC Operating Range 

10.5 – 15.9 VDC 

  Under Voltage Alarm 

11.0 VDC 

  Under Voltage Alarm Recovery

11.3 VDC 

  Under Voltage Shutdown 

10.5 VDC 

  Under Voltage Recovery 

12.0 VDC 

  Over Voltage Shutdown 

15.9 VDC 

  Over Voltage Recovery 

15.0 VDC 

  AC Output Socket 

NEMA 5-15 

EU, AU, UK 

Safety and Environmental 

  Agency Markings 

cETLus* 

CE LVD, EMC, 

 

  Operating Temp. 

0  to 40  (32  to 104 ) 

  Storage Temp. 

-20  to 60  (-4  to 140 ) 

  Relative Humidity 

5 - 90% non-condensing 

  Operating Altitude 

Up to 6,560ft (2000 m) above sea level 

Weights and Dimensions 

  Weights 

1.1 kg 

1.1 kg 

  Dimensions   

8.5 x 6 x 2.6” (218 x 152 x 66 mm) 

The product conforms to UL STD.458 and is certified to CSA STD. C22.2 No.107.1 

 

 

7. WARRANTY 

One Year Limited Warranty 

The limited warranty program is the only one that applies to this unit, and it sets forth all the 
responsibilities of KISAE. There is no other warranty, other than those described herein. Any 
implied warranty of merchantability of fitness for a particular purpose on this unit is limited in 
duration to the duration of this warranty. 
This unit is warranted, to the original purchaser only, to be free of defects in materials and 
workmanship for one year from the date of purchase without additional charge. The warranty 
does not extend to subsequent purchasers or users. 
Manufacturer will not be responsible for any amount of damage in excess of the retail 
purchase price of the unit under any circumstances. Incidental and consequential damages are 
specifically excluded from coverage under this warranty. 
This unit is not intended for commercial use. This warranty does not apply to damage to units 
from misuse or incorrect installation/connection. Misuse includes wiring or connecting to 
improper polarity power sources. 
 

Return/Repair Policy: 

If you are experiencing any problems with your unit, please contact our customer service 
department [email protected] or Phone 

1-877-897-5778

 before returning product to 

retail store. After speaking to a customer service representative, if products are deemed non-
working or malfunctioning, the product may be returned to the purchasing store within 30 days 
of original purchase. Any defective unit that is returned to manufacturer within 30 days of the 
date of purchase will be replaced free of charge. If such a unit is returned more than 30 days 
but less than one year from the purchase date, manufacturer will repair the unit or, at its option, 
replace it, free of charge. If the unit is repaired, new or reconditioned replacement parts may 
be used, at manufacturer’s option. A unit may be replaced with a new or reconditioned unit of 
the same or comparable design. The repaired or replaced unit will then be warranted under 
these terms for the remainder of the warranty period. The customer is responsible for the 
shipping charges on all returned items. 

 
Limitations: 

This warranty does not cover accessories, such as adapters and batteries, damage or defects 
result from normal wear and tear (including chips, scratches, abrasions, discoloration or fading 
due to usage or exposure to sunlight), accidents, damage during shipping to our service facility, 
alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for 
care and maintenance, fire and flood. 
If your problem is not covered by his warranty, call our Customer Service Department 
[email protected] or 

1-877-897-5778 

for general information if applicable. 

 
 
 
 
 
 
 

Service Contact Information 

Email:[email protected] 

Phone: 1-877-897-5778 

www.kisaepower.com 

 

 
 
 
 
 
 
 
 
 

  

 
 
 
 
 
 
 
Printed in China

 