For safe and optimum performance, the Power Inverter must be used properly. Carefully read 
and follow all instructions and guidelines in this manual and give special attention to the 
CAUTION and WARNING statements. 
 
 
 

PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE 

 

Disclaimer 
While every precaution has been taken to ensure the accuracy of the contents of this guide, 
KISAE Technology assumes no responsibility for errors or omissions. Note as well that 
specifications and product functionality may change without notice. 
 
Important 
Please be sure to read and save the entire manual before using your KISAE Power Inverter
Misuse may result in damage to the unit and/or cause harm or serious injury. Read manual 
in its entirety before using the unit and save manual for future reference. 

 
 
True Sinewave SW Series: 
  120V model 

SL1204           12V 400W 120VAC True Sinewave Inverter (US - NEMA 5-15) 

  230V model 

SL1204i-EU      12V 400W 230VAC True Sinewave Inverter 

(Schuko - CEE 7/4) 

SL1204i-UK     12V 400W 230VAC True Sinewave Inverter 

(British - BS1363)

 

SL1204i-AU     12V 400W 230VAC True Sinewave Inverter 

(Australia - NS/NZS 3112)

 

 
P/N: MU SL1204 Rev 1.1 
 
Service Contact Information 
Email: [email protected] 
Phone: 

1-877-897-5778 

 
Web: 

www.kisaepower.com

 

 

 

1. INTRODUCTION 

Thank you for purchasing the KISAE Power Inverter. With our state of the art, easy to use 
design, this product will offer you reliable service for providing AC power for your home, cabin, 
boat, RV or Trailer. The KISAE Power Inverter can run many AC-powered appliances when 
you need AC power anywhere. 
This manual will explain how to use this unit safely and effectively. Please read and follow 
these instructions and precautions carefully. 
 

IMPORTANT SAFETY INFORMATION 

This section contains important safety information for the KISAE Power Inverter. Each time, 
before using the KISAE Power Inverter, READ ALL instructions and cautionary markings on or 
provided with the inverter, and all appropriate sections of this guide. 
The KISAE Power Inverter contains no user-serviceable parts. See Warranty section for how 
to handle product issues. 
 
WARNING: Fire and/or chemical burn hazard 
• Do not cover or obstruct any air vent openings and/or install in a zero-clearance compartment. 
WARNING: Failure to follow these instructions can result in death or series injury 
•  When working with electrical equipment or lead acid batteries, have someone nearby in case 

of an emergency. 

•  Study and follow all the battery manufacturer’s specific precautions when installing, using 

and servicing the battery connected to the inverter. 

•  Wear eye protection and gloves. 
•  Avoid touching your eyes while using this unit. 
•  Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If 

this occurs, cleanse right away with soap and water for a minimum of 15 minutes and seek 
medical attention. 

•  Batteries produce explosive gases. DO NOT smoke or have an open spark or fire near the 

system. 

•  Keep unit away from moist or damp areas. 
•  Avoid dropping any metal tool or object on the battery. Doing so could create a spark or 

short circuit which goes through the battery or another electrical tool that may create an 
explosion. 

WARNING: Shock Hazard. Keep away from children! 
•  Avoid moisture. Never expose unit to snow, water etc. 
•  Unit provides household AC, treat AC output sockets the same as regular wall AC sockets at 

home. 

WARNING: Explosion hazard! 
•  DO NOT use the KISAE Power Inverter in the vicinity of flammable fumes or gases (such as 

propane tanks or large engines). 

•  AVOID covering the ventilation openings. Always operate unit in an open area. 
 

FCC and EMC INFORMATION  

This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules for 120V model and to comply with the limits for CE EMC 
standard on 230V models. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be determined by turning 
the equipment off and on, the user is encouraged to try to correct the interference by one or 
more of the following measures:  
•  Re-orient or relocate the receiving antenna.  
•  Increase the separation between the equipment and the receiver.  
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.  

•  Consult the dealer or an experienced radio/TV technician for help. 

 
LIMITATIONS ON USE 
Do not use in connection with life support systems or other medical equipment or devices. 
 

2. PRODUCT DESCRIPTION 

The KISAE Power Inverter package includes the items list below. 
•  Power Inverter base unit 
• Owner’s manual 
•  DC Input cable accessory 
 

3. INSTALLATION 

WARNING: KISAE Technology recommends that all wiring be done by a certified technician or 
electrician to ensure adherence to the applicable electrical safety wiring regulations and 
installation codes. Failure to follow these instructions can damage the unit and could also 
result in personal injury or loss of life. 
CAUTION: Before beginning your power inverter Installation, please consider the following: 
•  The Power Inverter base unit should be used or stored in an indoor area away from direct 

sunlight, heat, moisture or conductive contaminants. 

•  When placing the unit, allow a minimum of three inches of space around the unit for optimal 

ventilation. 

 

Understanding the unit features  

 

 

 

Installation Preparation 

Typical wiring block diagram of the Power Inverter: 
 

 

 
Battery Bank: 

•  The use of deep cycle battery is highly recommended for power inverter application 
•  For battery size, you need to identify how long you wish to operate the load(s). KISAE 

does recommend that you purchase as much battery capacity as possible. See more on 
“Estimated Run time and Load” in Section 4. 

•  Please use 12V Battery Bank system for the SL1204 and SL1204i series. Using 24V or 

higher voltage Battery Bank System will damage the inverter and may cause fire.  

 
Fuse or Circuit Breaker: 

•  DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required. 
•  Select a fuse or circuit breaker with 60A/16V minimum rating. 
•  Based on the size of the battery bank chosen on the 12V system above, determine the 

overall short circuit current rating of the battery bank from the battery manufacturer. The 
fuse or circuit breaker chosen has to be able to withstand the short circuit current that may 
be generated by the battery bank. 

 
Disconnect Switch: 

•  Select a Disconnect Switch with the same or higher rating of the selected fuse or circuit 

breaker from the above. 

•  The Disconnect Switch is used to disconnect the DC power between the power inverter 

and the battery bank during service, maintenance or trouble shooting. 

 

Installing the Power Inverter System 

WARNING: Electrical Shock Hazard 
The unit green ‘On/Off’ switch does not disconnect the DC power from the battery. Use the DC 
Disconnect Switch or disconnect the DC input cables connection to disconnect the DC power 
from the battery before working on any circuits connected to the unit. Failure to follow these 
instructions can result in death or serious injury. 
CAUTION: Unit Damage 
Reversing the battery connection to the DC Input terminals will damage the unit and it cannot 
be repaired. Damage caused by reverse polarity connection is not covered by the warranty. 
 
Power Inverter Installation 

Using the provided Accessories for temporary use 

 

 Lighter Plug Cable: 

CAUTION: Due to the limitations of the 12V lighter plug socket in vehicles, the unit should be 
used with the DC cable with lighter plug only to supply AC power to products that require  
150W (120VAC/1.3A or 230V/0.65A) or less. If the appliance requires more than 150W, use 
the DC Battery Clips Cable for battery connection. 
•  Attach the red ring-type connector to the positive (+) DC terminal (red) on the power 

inverter and connect the black ring type connector to the negative (-) DC terminal (black) 
on the Power inverter. 

•  Tighten the nut on each DC terminal. 
•  Insert the lighter plug of this cable to the fused 12V lighter plug socket. 
•  Unit is ready for use. 

 Battery Clips Cable: 

CAUTION: Please be sure all the connections are tight before the use of the unit. 
•  Attach the red ring-type connector to the positive (+) DC terminal (red) on the power 

inverter and connect the black ring type connector to the negative (-) DC terminal (black) 

Отзывы: