Fire safety
Pay attention that the distance of the chimney
from buildings and from any other burning
materials must be adequate. The distance must
be checked both laterally and vertically.
Laterally three (3) meters is practically
adequate distance from the chimney end to
burning materials. Alongside the chimney,
shorter distance is adequate. When close or
through the roof, must an insulated chimney be
used. In that case, the chimney must be at least
1 m over the roof level.
Notice also the fire safety in front of the furnace. There shouldn’t be any flammable materials near
the furnace. There should be an area, which is demonstrated in the picture that is made of
incombustible material such as concrete, sand or metal. You can ask your local fire safety officer for
further information.
Grates
For the pool heater, two cast iron grates and one L-formed iron plate
will be delivered. Those are to be positioned on the tracks in the heater.
The order of the grates is shown on the right side. Formed iron plate is
to be installed bended edge upwards. It will deflect the air and also
prevent the firewood to drop out from the heater.
Usage of the heater
The heater is meant to be used together with the filtration system for heating the water of the
swimming pool. Only when the heater is attached to the water circulation, heater tank is filled with
water and the water is circulating, it is safe to start the fire in the heater. The minimum water
circulation rate in the heater while fire inside is 2 cubic meters / hour. This way the heat exchanger
will lead enough heat into the water.
You should use only dry wood as firewood.
During the heating you should check every 10
minutes that the water is circulating in properly through the heater.
Keep the fire up to continue heating while the water is circulating. Remember that you shouldn’t
heat the water over 37 °C. Much cooler water can be used in swimming pools. Notice also that the
plastic parts of the water circulation system may start to soften when the water temperature
reaches 50°C, so try to avoid excess heating.