Grates
Cult stoves come with a cradle fireplace grate where a single wire tray grate is
installed. An air iron plate is placed on the top shelf to direct the circulation of
air in the upper part of the firebox. The plate in the upper part of the stove
must not be pushed too far so that it prevents the exhaust of the smoke. It is
prohibited to use the stove without these parts. Note that these parts wear
down over time and get bent and their form will change in use. You can
purchase new ones as spare parts when needed.
Chimney
Be careful, the edges of the chimney are very sharp. Use protective
gloves! The chimney is delivered in a separate box and it consists of four
parts (picture on right) and it needs to be assembled. Remove the
protective film from the thermal protection and place the assembled
chimney to the chimney outlet of the stove.
The first use
The water circulation of the stove shall be rinsed by letting plenty of water in from the pipe above,
so that any metal chips from grinding come out. Collect any trash by swiping it off the bottom of the
tub. When you fill the tub, check the fastening pipes of the stove for any leakages.
USE
When filling the tub, note the number of people because people entering the tub will displace the
water when they enter the tub. If there will be many people in the tub, leave the water surface at
the minimum.
In case you are using your own pump for filling the tub, remove the pumping hose after you have
filled the tub. Many pumps do not have a return valve to prevent the water discharge from the tub
when the pumps are switched off. Before filling the tub, check that the bottom plug of the tub is
closed, ensure that the plug is in place after you have some 10 cm of water in the tub.
Minimum fill:
The tub needs to be filled at least 5 cm above the upper
connection pipes of the stove before lighting the fire in the
stove (picture on right).
Do not let a full tub freeze in the winter. Empty the tub or
ensure appropriate heating.
Do not connect the stove to the circulation pump; it cannot
ensure the pressure because it is planned only for
gravitational circulation.
Note about the minimum fill and heating the
stove!
The tub stove must never be lighted when the tub is empty or not full! Heating a half-
empty tub will lead to melting the stove! You must not start emptying the tub before the
27/76
Содержание Original Easy
Страница 4: ...4 76...
Страница 5: ...5 76...