14
colour signal
outputs
red
blue
grey
not sunny/sunny 0 V/1 V
both signals ground
direct radiation, 1 W/m
2
1 mV
colour power
input
brown
yellow
power supply + 12 VDC
power supply ground
colour heater
inputs
white
black
green
heater supply 10 W +12 VDC
both heaters common 0 V
heater supply 1 W +12 VDC
Figure 1.3.3 wiring schedule of CSD 1. Outputs: sunshine duration, direct
radiation, Inputs: heater low, heater high, power supply.
1.4
MEASUREMENT OF SUNSHINE DURATION
For measurement of sunshine duration, connect the power supply input and
the sunshine duration output. If the direct radiation level is higher than 120
W/m² by definition the time should be added to the sunshine duration. The
output voltage is 1 V. When the sun is not shining the output is 0V.
The usual procedure is to integrate the period with high output, and to store
either the 1 minute values or the totals for each day.