background image

 

 

 

Содержание KGE2400X

Страница 1: ......

Страница 2: ......

Страница 3: ...rator and should remain with it if it is resold Pay special attention to statements preceded by the following words Failure to properly follow these precautions can result in property damage serious i...

Страница 4: ...e engine damage Indicates a strong possibility of severe personal injury or death if instructions are not followed Indicates a possibility of personal injury or equipment damage if instructions are no...

Страница 5: ...entification of components 3 3 Pre operation check 5 4 Starting the generator 8 5 Using the generator 9 6 Stopping the generator 13 7 Maintenance 14 8 Storage 17 9 Troubleshooting 18 10 Specifications...

Страница 6: ...v This page left intentionally blank...

Страница 7: ...ide adequate ventilation The muffler becomes very hot during operation and remains hot for several minutes after stopping the engine Be careful not to touch the muffler while it is hot Let the engine...

Страница 8: ...lity power is restored the generator may explode burn or cause fires in the building s electrical system This generator is not designed to be connected to an automatic transfer switch ATS Serious dama...

Страница 9: ...DENTIFICATION 2 1 Generator Components 8 1 2 3 9 4 5 6 7 10 1 Fuel Gauge 6 Oil Filler Cap 2 Choke 7 Control Panel 3 Fuel Valve 8 Gasoline Tank 4 Air Cleaner 9 Spark Plug 5 Recoil Starter 10 Muffler 2...

Страница 10: ...s found in three locations on the generator front panel on the packing carton and on the owner s manual inside cover The bar code identifies the production date and is used by your dealer and the cust...

Страница 11: ...a clean lint free rag Reinsert the oil filler cap without rotating it Remove the oil filler cap and examine the oil level If the oil level is at or below the lower level refill the oil to the upper l...

Страница 12: ...area with the engine stopped Do not smoke or allow flame or sparks in the area where the engine is refueled or where gasoline is stored Do not overfill the fuel tank there should be no fuel in the fi...

Страница 13: ...ll the high altitude main kit No other adjustments to the carburetor are necessary Even with suitable carburetor re jetting engine horsepower will decrease approximately 3 5 for each 1000 feet or 305...

Страница 14: ...he AC breaker 2 Set the fuel oil valve to ON position 3 Set the choke lever to CHOKE position 4 Set the engine switch to ON position 5 Pull the starting handle until you feel resistance then pull it f...

Страница 15: ...than 30 continuous minutes 4 This set is not designed to be connected directly to a residential service panel Use a manual style transfer switch Do not connect this generator to an automatic transfer...

Страница 16: ...e appliance to the generator connect the one with the higher current draw first Let it come to normal operation before connecting the second appliance WATTAGE MULTIPLIER TYPICAL APPLIANCE WATTAGE TYPE...

Страница 17: ...tery terminal and the vehicle s frame or body Do not attempt to start an automobile engine with the generator still connected to battery The generator may be damaged Connect the positive battery termi...

Страница 18: ...protected from an overload with a fuse If the DC circuit is overloaded the 5 amp fuse will blow and power to the DC receptacle will cease The red light on the DC panel will illuminate Replace the fuse...

Страница 19: ...off the AC breaker 6 2 Put the engine switch in the off position and turn the fuel cock to OFF 6 2 Emergency Shutdown To stop the generator in an emergency turn the engine switch OFF CAUTION Continual...

Страница 20: ...years Replace if necessary 3 Note 1 Perform at every indicated month or operating hour interval whichever occurs first Log hours of operation 2 Shorten maintenance intervals if the generator is opera...

Страница 21: ...limit level of the oil filler cap 5 Reassemble the oil filler cap 7 2 Air cleaner Service 1 Unfasten the clips and remove the air filter cover Remove the air filter element and observe for cleanliness...

Страница 22: ...e of the electrode Reinstall the plug securely in the cylinder head Use enough force to compress the washer but take care not to over tighten to turns is sufficient 7 4 Spark Arrestor Maintenance 1 Al...

Страница 23: ...supply with a suitable fuel preservative Exercising the Generator Any small engine is very susceptible to fuel varnishing Gasoline fuel systems have very small orifices and passageways which can easi...

Страница 24: ...drain when the fuel valve is turned on Is there fuel in the tank Is the engine switch on Is the fuel valve on Is the enough oil in the engine Is there a spark from the spark plug Replace the spark plu...

Страница 25: ...n the ON position Place in the ON position Check the electrical appliance or equipment for any defects Take the generator to an authorized dealer Replace the electrical appliance or equipment Take the...

Страница 26: ...ompression ratio 8 5 1 Frequency 60 Hz Voltage 120 Max output 2 4 KW Max current 20 A Rated output 2 2 KW Rated current 18 3 A Excitation method Self excitation AVR Phase Single phase Power factor 1 S...

Страница 27: ...21 11 WIRING DIAGRAM...

Страница 28: ...to repair or replace these parts at its option Coast Distribution may request defective parts to be returned Anything replaced under warranty becomes the property of Coast Distribution TO OBTAIN WARR...