9. Use your turn signals, checking for traffic well in advance of turning

If the tractor  is not 

equipped with turn signals and law requires them, install them prior to operating on or near 

public roads. 

 

 

Safety Decals 

 

1. Keep decals clean. Remove dirt with a wet clean cloth when necessary. 

2. Replace safety decals if destroyed, missing, painted over or unreadable. If any safety decals 

are covered or  obscured when the ROPS  is mounted,  it is recommended that you purchase 

replacement decals from the tractor manufacturer. Mount them in a readable location at, or 

near, their original location before operating the tractor. 

3. New ROPS decals and tractor decals are available from your tractor dealer. 

 

 

ROPS Safety 

 

1. Install the ROPS in accordance with Tektite mounting instructions. Failure to do so may affect 

the ROPS ability to withstand a roll over.  

2. If the ROPS is subjected to alteration, structural damage or involved in an over turn accident, 

the entire structure must be replaced. Failure to do so may result in injury or death in the event 

of a roll over. 

3. If the tractor in not equipped with seat belts, purchase approved seat belts from the tractor 

manufacturer or Tektite prior to operating the tractor. 

4. Always fasten seat belts prior to operating the tractor. 

5. Always operate the tractor from the operator’s seat. 

6. Remove mud, crop residue, chains and tools from steps and operator’s platform. They may 

interfere with pedal operation or entry/exit from the tractor. 

7. Remove all loose chains, tools, and equipment from the operator’s platform. Failure to do so 

may cause injury or death in the event of a roll over. 

8. Do not install the ROPS on a tractor model that the ROPS is not designated for (compatible 

tractor  designations  are  printed on the ROPS  serial number plate).  The ROPS is designed 

specifically for individual models to ensure ROPS requirements will be met. Installing the ROPS 

on a non designated tractor may result in injury or death. 

 

Emergency Exits 

 

The ROPS cab has two doors, either one can be used during an emergency. 

 

 

     November 2021© Kioti CS2520 ROPS Cab Operation Manual

Содержание CS2520 Series

Страница 1: ...2220 tractor Designed and Built by Tektite Manufacturing Inc 427 Buffalo Street P O Box 639 Winkler MB R6W 4A8 Canada PH 204 331 3463 Fax 204 331 4159 parts tektite ca www tektite ca One year standard...

Страница 2: ...heavy A lift assist device such as an overhead hoist or high lift forklift is required 4 Ensure your work area is well ventilated The installation requires the starting of the tractor which will produ...

Страница 3: ...rence only All directions provided are from the reference point of the tractor seat facing the steering wheel All left and right references are from this view point For reference please fill in the in...

Страница 4: ...nefit of any transferable warranty accorded to Tektite by third party manufacturer i defects in workmanship or materials in products or components that are repaired or replaced by Tektite unless Tekti...

Страница 5: ...service if they are operated and maintained according to instructions It is the owner s responsibility to be certain anyone operating this product reads this manual and all other applicable manuals to...

Страница 6: ...evices and shields are intended to protect operators from injury or death Under no circumstances should they be modified disabled or removed Operating Safety 1 Always operate the tractor controls whil...

Страница 7: ...lds that are not designed as steps Safe Highway Operation 1 Before operating the tractor on or near public roadways check with your local authorities for any local regulations that will affect you 2 E...

Страница 8: ...ntire structure must be replaced Failure to do so may result in injury or death in the event of a roll over 3 If the tractor in not equipped with seat belts purchase approved seat belts from the tract...

Страница 9: ...one switch plate located in the cab The following switches are available and their functionality is described Cab Switch Plate 1 Front Wiper Rocker Switch standard Low position Off High position On N...

Страница 10: ...n against individual circuit overload All optional components are fused internally behind the cab switch plate After your ROPS Cab has been installed Before starting a tractor equipped with a Tektite...

Страница 11: ...triker Service Parts Breakdowns Following are parts breakdowns for components that may require service parts replacement during the life of the ROPS If you require replacement parts please contact the...

Страница 12: ...c 427 Buffalo Street Winkler MB R6W 4A8 Canada CNC Index Service Part File Name Description Qty 1 A00 0013 TEKT 0009 5MM Bushing 5 2 A00 0014 TEKT 0092 Thick Bushing 3 3 A00 0019 STEP BOLT1 4X1 Step B...

Страница 13: ...RIGHT LATCH Suicide Door Right Latch 1 3 A00 0013 TEKT 0009 5MM Bushing 15 4 A00 0018 STEP BOLT1 4X1 1 2 Step Bolt 1 4 x 1 1 2 MB 3 5 A00 0020 STEP BOLT1 4X1 1 4 Step Bolt 1 4 x 1 1 4 MB 4 6 A00 0021...

Страница 14: ...ng Inc 427 Buffalo Street Winkler MB R6W 4A8 Canada CNC Index Service Part File Name Description Qty 1 A00 0013 TEKT 0009 5MM Bushing 5 2 A00 0014 TEKT 0092 Thick Bushing 3 3 A00 0019 STEP BOLT1 4X1 S...

Страница 15: ...00 0002 LEFT LATCH Suicide Door Left Latch 1 3 A00 0013 TEKT 0009 5MM Bushing 15 4 A00 0018 STEP BOLT1 4X1 1 2 Step Bolt 1 4 x 1 1 2 MB 3 5 A00 0020 STEP BOLT1 4X1 1 4 Step Bolt 1 4 x 1 1 4 MB 4 6 A00...

Страница 16: ...Street Winkler MB R6W 4A8 Canada CNC Index Service Part File Name Description Qty 1 A00 0013 TEKT 0009 5MM Bushing 8 2 A00 0019 STEP BOLT1 4X1 Step Bolt 1 4 x 1 MB 4 3 A00 0021 FLANGE NUT 1 4 Flange...

Страница 17: ...ffalo Street Winkler MB R6W 4A8 Canada CNC Index Service Part File Name Description Qty 1 A00 0013 TEKT 0009 5MM Bushing 8 2 A00 0019 STEP BOLT1 4X1 Step Bolt 1 4 x 1 MB 4 3 A00 0021 FLANGE NUT 1 4 Fl...

Страница 18: ...ise specified X X 1 16 Angular 1 0 Drawn By Checked By Size File Name Units Date Date Req d Description Tektite Manufacturing Inc 24157 Hwy 3 Box 639 Winkler MB R6W 4A8 Canada CNC Index Service Part F...

Страница 19: ...1 4 x 3 4 YD 4 4 A00 0061 TEKT 0021 Striker Mounting Plate 2 5 A00 0084 TEKT 0070 Gas Shock 2 6 A00 0085 TEKT 0069 Gas Shock Stud 2 7 A00 0101 STRIKER PIN Striker Pin 2 8 A00 0103 HEX NUT M12X1 Hex N...

Отзывы: