EN UG-020 Link 6 user guide r1.0
255
Procedure
1.
Fix the wall mount to the controller with the M6 screws such that the I/O panel is on the side
opposite to the UP arrow on the mount.
The fastening screws must be torqued to 10 N·m.
2.
Fix the controller with the wall mount to the vertical surface with the M8 screws.
The fastening screws must be torqued to 8 N·m.
Gigabit Ethernet adapter
The Gigabit Ethernet adapter is used for tools that require an M12 X-coded connector.
The Gigabit Ethernet adapter is compliant with ISO 9409-1-50-4-M6. It replicates the ISO
9409-1-50-4-M6 flange and central pogo pins. 24 VDC flows through the adapter. It has an
communication port. All of this put together is sufficient to power most tools without needing
wires.
It has mounting points so that other tools, such as third-party cameras, can be installed.
It can be installed on the wrist at 0 ° or at 180 °.
Figure 211: Wrist side of the Gigabit Ethernet
adapter
Figure 212: Output side of the Gigabit Ethernet
adapter with close-up view of the printed
circuit board pad
Related topics
on page 17
on page 20
on page 20
on page 45
Dimensions of the Gigabit Ethernet adapter
The adapter can connect nearly any tool to Link 6, provided the dimensions of the Gigabit
Ethernet adapter are taken into account.
+1 514-277-3777
kinovarobotics.com
© 2022 Kinova inc. All rights reserved.
Содержание Link 6
Страница 1: ...Link 6 user guide Optional gripper shown ...
Страница 8: ......