DCP 30 LX / DCP 30 SX
Issue: 11/2009
24
3 .4 .5 Internal Water Cooling Unit (only DCP 30 SX)
The Light Engine and the integrator are water-cooled. The DCP 30 SX is cooled via an
internal water cooling system and the DCP 30 LX by an external KWK-DCP.
X
NOTE
See also operating manual of the KWK-DCP water cooling system.
The continuous cooling of the Light Engine’s modules are very important.
If the coolant flow interrupts or if the coolant flow is too low, the xenon lamp will be auto-
matically switched off to avoid damage of the components.
Heat exchanger
Tank
Â
Drain hose and filling level indicator
The continuous fluid flow and the tem-
perature of the coolant is monitored by
sensors in the Light Engine.
- If the fluid flow is low or interrupted
the xenon lamp will be switched off for
safety reasons.
- If the coolant temperature exceeds
an upper limit the xenon lamp will be
switched off for safety reasons.
In both cases the status lamp on the top
of the projector head illuminates red and
the touch panel PC or the external PC
monitor indicates an error.
3 .4 .5 .1 Cooling Fluid
The cooling fluid is a composition which is perfectly adapted to the digital projector.
Kinoton has 1 liter bottles with of cooling fluid available.
X
NOTE
Z
Never use water or other cooling fluids.
Z
Refilling or changing the cooling fluid and de-aerate the system, see „6.3.3 Refilling /
Changing the Cooling Fluid / D-Aerating the System“.
1
2
3