7
Ballast Power
The Tegra 4Bank DMX requires 100-240VAC 50/60 Hertz on an earth
grounded circuit. The electronic Ballast operates at a high frequency of 40kHz.
It is lightweight, flicker-free and dead quiet.
Warning! To Ensure Proper Operation
ALWAYS TURN OFF THE FIXTURE BEFORE
connecting or disconnecting lamps. After the lamps
are properly installed, the in-line switch can turn on
the ballast.
Cold Temperature Operation
The Tegra 4Bank DMX is designed to operate at temperatures from
14F to 122F (-10C to +50C). In cold temperatures, the ballast may not
strike the lamp(s). Switch the ballast to OFF. Make sure onboard dimmer is
full up and re-strike.