Страница 2: ... Plate 1 Extension Cable 1 Select DMX 4Bank Ballast CFX 4804 4ft 4Bank Fixture CFX 2404 2ft 4Bank Fixture MTP K41 Mounting Plate w 3 8 Pin X16 25 4Bank Extension 25ft BAL 450 120 Select Dmx 4Bank Ballast 120VAC BAL 450 230 Select Dmx 4Bank Ballast 230VAC ...

Страница 3: ...urn fastener and two clips To Release the Lamp Harness Remove the harness from 2 clips located under the reflector Rotate the turn fastener clockwise to release harness The lamps can operate independent of the fixture allowing them to be built into sets or custom soft boxes or hand held as a single tube for an eye light WARNING Always use safety coated lamps to avoid injury if lamp breaks ...

Страница 4: ...p pins Match the Harness color codes at each end of the lamp Push lamps into the fixture s Lamp Holder Clips Lamp Harness Color Codes The Harness wiring is color coded The same color code must match at each end of the lamp for proper operation RED YELLOW BLACK BLUE 4Bank Harness ...

Страница 5: ... pin will snap into place when the plate is properly seated Restricting the airflow around the lamps can cause the lamp to operate hotter This increased heat will raise the lamp s color temperature and green spike Therefore it is recommended to clip gels to the Doors of the Fixture Do Not clip gels to louver Do Not block the fixture ends in a manner that restricts airflow ...

Страница 6: ...ockwise The standard mount comes with a 3 8 Lollipop that clamps into a grip head The ball and socket mount allows the fixture to be oriented in a broad range of angles The yellow wire loops provide attachment points for a safety chain The grommet holes along the edge of the fixture are designed to allow the fixture to be screwed onto set walls MTP LB MTP LBT ...

Страница 7: ...r Extension Cables 2 Use only with Sine wave inverters Do not operate on SCR dimmers 3 If powering the ballasts through a Dimmer Pack set the Dimmer to Non Dim Mode The 120 VAC Ballast requires 110 to 130 Volts AC 50 60 Hertz on an earth grounded circuit the 230 VAC Ballast requires 220 to 240 Volts AC on an earth grounded circuit The electronic Ballast operates at a high frequency of 25KHz It is ...

Страница 8: ... that the Extension and Harness connections are secure and re strike Once operating for a few minutes the Lamps should re strike instantly Lamp Select Feature The Select Ballasts have a 4FT 2FT switch Set the Selector Switch to 4FT for 4ft lamps and 2FT for 2ft or 15 lamps The Ballast operates remote from the fixture Connect the Extension cable to the Ballast and the Lamp Harness After the lamps a...

Страница 9: ...d FIXTURE methods of DMX control F DMX Address Sets DMX Address of Fixture G Lamp Select Set to 4ft for 4ft lamps and 2ft for 2ft or 15 lamps H Manual Switches Turns lamps on and off manually A E F G H B D C Lamp Select feature continued When operating 4ft lamps in high ambient temperature or where the units are rigged into place with restricted airflow the 2FT setting can be used to lower the col...

Страница 10: ... Unplug the DMX cable or 2 Leave cables plugged in and set address to 000 There is a 5 second delay when switching between DMX and Manual control Manual lamp switching is not affected by DMX control The DMX Terminate Switch must be set to open O on Ballasts within the DMX chain Set to closed I when the Ballast is the last DMX control device in the chain Note When the last Ballast s DMX Terminate S...

Страница 11: ...ata to be passed through for other equipment Do Not use Microphone Cables and other general purpose two core Cables designed for audio or signaling use They are not suitable for DMX512 Problems due to incorrect cabling may not be immediately apparent Microphone Cables may appear to work fine but systems built with such Cables may fail or be prone to random errors Cable must comply with EIA 485 RS4...

Страница 12: ...eature program the 5 th address 005 at full Setting the dimmer value under 49 or not programming address 5 will restore the 4ft setting 4Bank Lamp Sequence One of the best applications for the Fixture Mode is when lighting Blue and Green Screens or large Cycloramas For example One row of fixtures can be set to Fixture mode on a common address When the fader on the dimmer board is brought up or dow...

Страница 13: ...Bank to Single or Double splitter A Single splitter can provide 4 individual cable feeds to lamps or fixtures in a set For parts see page 16 After the DMX address is entered the Select DMX 4Bank automatically assigns the next 4 addresses to lamps 2 3 4 and the 5th address controls the 2ft setting On address 5 to activate the 2ft lamp setting set dimmer slider to full Setting the dimmer value under...

Страница 14: ...ddress 005 010 015 etc for 2ft operation 4 Program lamp sequence to chase from 001 through 004 006 009 011 014 and so on 5 Set end of line switch to I on the last unit in the DMX chain To Chase same lamp position simultaneously through multiple fixtures 1 Set ballast to Individual Lamp mode 2 Set each ballast address to 001 or a common address 3 Program address 005 010 015 etc for 2ft operation 4 ...

Страница 15: ... 4ft 4Bank Flozier Half DFS D4 2ft 4Bank Flozier Full DFS D4 H 2ft 4Bank Flozier Half MTP B41 Twist On Mount w Baby Receiver MTP B41S Twist On Mount w Baby Receiver Short MTP B41T Twist On Mount w Baby Receiver Straight MTP L Lollipop 3 8 Pin MTP LB Lollipop w Baby Receiver MTP LBS Lollipop w Baby Receiver Short MTP LBT Lollipop w Baby Receiver Straight MTP BAL Select Ballast Mount ...

Страница 16: ...4Bank to Single Splitter X16 A9 4Bank to Double Splitter X09 25 Double Ext Cable 25ft X09 12 Double Ext Cable 12ft X04 25 Single Ext Cable 25ft X04 12 Single Ext Cable 12ft HAR 4804 4ft 4Bank Harness HAR 2404 2ft 4Bank Harness HAR 4802 4ft Double Harness HAR 2402 2ft Double Harness HAR 4801 4ft Single Harness HAR 2401 2ft Single Harness ...

Страница 17: ...re Dimensions Barndoor Weight Fixture Style Length Width Depth Width w Lamps 2ft 4Bank 27 00 13 3 5 6 5 7 5 lbs 4ft 4Bank 52 00 13 3 5 6 5 11 5 lbs EXP LHC T12 Lamp Holder Clips T12 24pk EXP M T Adhesive Mounts and Releasable Ties 25pk PRT HLC Kino Locking Lamp Connector 1pk ...

Страница 18: ...mp Foam Pad 24 x 9 x 1 N A Fits KAS 48 72 96 61 x 23 x 2 5cm INS L6 6 Lamp Foam Pad 24 x 13 x 1 N A Fits KAS 54S 54L 61 x 33 x 2 5cm 96L Kino Flo Double Fixture Dimensions Barndoor Weight Fixture Style Length Width Depth Width w Lamps 2ft Double 27 00 7 5 3 5 6 0 4 7 lbs 4ft Double 52 00 7 5 3 5 6 0 7 7 lbs Kino Flo Single Fixture Dimensions Barndoor Weight Fixture Style Length Width Depth Width w...

Страница 19: ...AS 54L 4ft Fixture Ship Case 57 x 15 x 17 25lb 11 3kg 4ft 4Bank Fixture 5 Large 145 x 38 x 43cm KAS 54S 4ft Fixture Ship Case 57 x 15 x 11 5 21lb 9 5kg 4ft 4Bank Fixture 3 Small 145 x 38 x 29cm KAS C26 6 Lamp Carry Case 26 5 x 6 x 4 1lb 5kg 2ft Lamps 6 2ft 67 5 x 15 x 10cm KAS C46 6 Lamp Carry Case 50 5 x 6 x 4 1 5lb 7kg 4ft Lamps 6 4ft 128 5 x 15 x 10cm KAS GAF Gaffer Kit Ship Case 55 x 12 x 19 5...

Страница 20: ...ns BAL 450 120 Select Dmx 4Bank Ballast 120VAC Input Voltage 120VAC 50 60Hz Output Frequency 25 kHz Amperage F75 4 6A F40 3 2A F30 2 5A Lamp switching 4 1 off Output Switching 4ft 2ft Ballast size 12 5 x 12 5 x 2 5 32 x 32 x 6 5cm Weight 6 5lb 2 9kg BAL 450 230 Select Dmx 4Bank Ballast 230VAC Input Voltage 230VAC 50 60Hz Output Frequency 25 kHz Amperage F75 2 4A F40 1 7A F30 1 3A Lamp switching 4 ...