Manual 1843 Rev C p/n 001843 0000
Recommended Oil
The oil recommended for KT pumps in most
applications is KV-100 oil. KV-100 is specially
formulated to provide peak lubrication even in
arduous conditions and provide high pumping
capacity at low pressures. They are also
formulated to resist rust and oxidation. These
properties further enhance the performance and
durability of Kinney KT pumps.
See Table 7-1
for a list of recommended oils by
service type. LT oil may be required where low
temperature starting or process contamination is
encountered. Kinlube 220 may be recommended
where a fire retardant fluid is required. Halocarbo
125 is an inert fluid recommended for oxygen
service and for highly corrosive applications. S500
is a synthetic vacuum oil, and may be used when
the pump is run at elevated temperatures to avoid
contamination, or in other applications where a
petroleum-based oil is undesirable.
SERVICE TYPE
RECOMMENDED OIL
ISO GRADE
Standard
KV100
100
Refrigeration
POE
68
Brake Fluid
UCON
68
Ammonia
POE
68
Oxygen
Fomblin or other PFPE
100
Radiator Fill
KV100
100
High Temp
S500
100
Table 7-1 – Recommended Oils by Service Type
FACTORY SERVICE AND REPAIR
With proper care, Kinney vacuum pumps and
systems will provide years of reliable service.
Should adjustments or parts replacement
eventually be needed, these can often be
performed locally as described in this book after
obtaining required parts. Personnel should have a
good background of mechanical experience and be
thoroughly familiar with the procedures outlined in
this manual.
For major repairs not covered in this manual,
contact the nearest Kinney Authorized Service
Center. Pump repair services are also available
at our factory in Springfield, MO, or through ou
international network of Authorized Service Centers.
Call (800) 825-6937 for the location nearest you for
more information. Units that are still under warranty
must be returned to the factory, freight prepaid,
for service. Please contact Customer Service or
visist us online for additional instructions on how to
receive a Return Authorization number.
Current regulations require Material Safety
Data Sheet to be completed and forwarded
to Kinney on any unit being returned for any
reason which has been handling or involved
with hazardous gases or materials. This is
for the protection of the employees of Kinney
who are required to perform service on this
equipment. Failure to do so will result in
service delays.