2
1 3 4
5 6 8
7
Check level,
distance
and Height
Drill
Tank
Apply
Base
Measure
Tank
Set Dip
Switches
Pair the
Receiver &
Transmitter
Fit
Transmitter
to the Base
Check
the
level
Read fully befoRe installation and use
a
RECEIVER
b
SCREWS
C
WATCHMAN ALARM TRANSMITTER
d
WATCHMAN ALARM BASE
e
WEATHER SEAL
1
CHECK LEVEL, DISTANCE AND HEIGHT
Suitable for use in tanks for the storage of diesel fuel, kerosene,
and gas oil types A2, C1, C2 and D as defined by BS 2869. Check
with the manufacturer and/or supplier before using with any
other fluids.
Ensure before you start your install that the tank the
WatchmanAlarm is to be fitted to is:
1.
Level
(See Picture 1)
2.
Within a 200-metre range of the line of sight of receiver position.
3.
A maximum height of 3 meters
2
TANK PREPARATION
Please note- it is important to keep all items dry
during installation.
A) PRE-DRILLED TANKS.
There may already be a 32mm pre-drilled opening in the
tank top and possibly a tube fitted. If so, remove the cover
by undoing the two screws holding it in place, and dispose
of the tube in accordance with local government guidelines.
NB – Ensure the hole is a minimum DIAMETER 30mm.
B) UN-DRILLED TANKS.
Where drilling is required to fit the
transmitter, choose a flat level point
that is at the same level and no higher
than any opening at the top of the
tank (filling point etc.). (
See Picture 2)
The Transmitter can’t sit at an
angle as this gives an incorrect
level reading on the receiver. Take
care not to choose an area on
which water could gather i.e.
a dent/depression or a position
directly above any restricted area
inside the tank. (
See Picture 3)
NB: For Windowed Tanks ensure
that the WatchmanAlarm is not
positioned above the area of the
WINDOW. If the WatchmanAlarm
is positioned over the WINDOWED
area it transmits faulty readings
to the receiver.
(See Picture 4)
Drill a hole in the place that you
have selected on the tank’s top
surface using a 32mm hole-saw.
(
shown in Picture 5)
3
FITTING TRANSMITTER BASE
For tanks with pre-drilled holes
• Remove cap from the hole
(Picture 6)
and insert
transmitter base, ensuring the weather seal is securely
in place
(Picture 7 & 8)
.
• Tighten the WatchmanAlarm base
(Part D)
on to the tank with
2 stainless steel self-tapping, counter sunkscrews supplied
(Part B)
. Do not over tighten!
SPECIFICATIONS
Tank Depth
Minimum depth: 0.5m.
measurement:
Maximum depth: 3m.
Display:
Bar graph level display, 10% tank height per bar.
Early warning indication (flashing tank fill)
at a predetermined height above tank bottom
(see section 11)
. Tank empty warning flashes
red LED at a predetermined height from tank
bottom.
(see section 11)
Meets EN60335.
Max
200m in normal “line of sight” conditions.
communication
The effective range of this product can be
distance:
influenced by external sources that may reduce the
range of the transmitter or sensitivity of the receiver.
Power supply:
Receiver: 150-250V, 50-60HZ.
Transmitter: 3-voltlithium cell.
Battery life:
3 years (estimated life).
Wireless com:
433 mHz. FM transmission.
EN 300-220, FCC part 15.
Dimensions:
Receiver: 50 x 55 x 35mm (not including aerial).
Transmitter: 70x93mm.
Max and min
Operating temp. Range -10º to +60 º C.
operating temp.
Operating humidity: 0-100%.
(transmitter):
Sealed airtight unit made from
PP3317 UV stabilized.
Hole size
32mm
for tank fitting:
2” BSP external thread adaptor
Declaration
: this apparatus is designed to: Not give rise to physical injury
or other harm due to contact. Not to produce excessive surface temperatures,
infrared, electromagnetic, ionising radiation. To have no non-electrical dangers.
When used in accordance with these user and installation instructions.
Warning
: If the equipment is likely to come in to contact with aggressive
substances, then it is the responsibility of the user to take suitable precautions
that prevent it from being adversely affected, thus ensuring that the type of
protection is not compromised. Aggressive substances; - e.g. liquids or gases
that may attack metals, or solvents that may affect polymeric materials.
In order to minimize the risks of electric shock,
i
The receiver is for indoor use only, never use outdoors.
i
The receiver is a sealed unit; do not attempt to open it.
1
3
5
5
6
7
8
© Kingspan Environmental 01-10-2008 TMG
FOR SUPPORT CONTACT:
Warranty: 1 year.
1
Visit our website
www.sensor-systems.com
Supplied by Kingspan Environmental
180 Gilford Road, Portadown, Co. Armagh, Northern Ireland
Safety Information
Do not replace in a potentially explosive atmosphere
Periodically check that the unit is intact and securely fastened to the tank.
Check with the manufacturer on the chemical compatibility prior to use.
Do not attempt to repair this equipment. It must be returned to the
manufacturer for repair.
Warning! Electrostatic hazard! Clean only with damp cloth.
Use only VARTA CR2430 batteries.
Not suitable for pressurised containers. Use on tanks vented to atmosphere.
4
3
a
b
C
d
e
Choose a suitable
position for transmitter
Outlet
Incorrectly
positioned
WatchmanAlarm
Fill
Point
Example of a windowed tank
installation instRuCtions
2
OIl AlARM
In the event of the oil level in the tank dropping at a rate that is not
common for a domestic oil tank the receiver will emit a siren type sound
that indicates a theft/leak is occurring.The siren will continue to go off even
after the level has stabilized and can only be reset by turning on and off the
power to the receiver.
This product is to be used only on domestic oil tanks within the parameters
outlined in the specifications. Any use of the product on applications that lie
outside a domestic environment is done so at users own risk.
5 013573 876212
Kingspan Environmental Ltd
Sensor Systems Team
180 Gilford Road, Portadown, Co. Armagh,
Northern Ireland BT63 5LF.
Sales Hotline:
+44 (0) 28 3836 4411
Watchman Helpline:
+44 (0) 28 3836 4414
Fax:
+44 (0) 28 3836 4412
Email:
SEnSor
Is PART oF
KingSpan EnVironmEntal