Hot Water Energy Storage
Unvented Cylinders
GB & NI
Installation & Maintenance Instructions for an unvented
hot water cylinder with external thermal expansion
SLIMLINE INDIRECT
B
F
C1
G1
D1
E
A
D1
CONNECTIONS:
A
2
2mm Cold feed with dip pipe to diffuser
in bottom of cylinder
B
22m Hot water outlet
C1
Immersion heater
C2
Secondary immersion heater
250 & 300 litre cylinders only
D1
22mm Boiler coil connections
D2
22mm Solar coil connections
E
1
/
2
" Temperature relief valve connection
(valve factory-fitted to cylinder)
F
22mm Secondary return – for cylinders with
a capacity of 210 litres only
G1
Dry stat pocket
G2
Dry stat pocket
Capacity
(L)
Height
(mm)
Dia
(mm)
A
(mm)
B
(mm)
C1
(mm)
C2
(mm)
D1
(mm)
D2
(mm)
E
(mm)
F
(mm)
G1
(mm)
G2
(mm)
60
716
478
440
716
380
n/a
340
n/a
485
n/a
395
n/a
90
1091
478
440
1091
380
n/a
340
n/a
858
n/a
395
n/a
120
1279
478
440
1279
380
n/a
340
n/a
1046
n/a
395
n/a
150
1467
478
520
1467
420
n/a
380
n/a
1234
n/a
520
n/a
180
1717
478
520
1717
420
n/a
380
n/a
1484
n/a
610
n/a
210
2030
478
520
2030
420
n/a
380
n/a
1797
1500
710
n/a
25˚
40˚
45˚
35˚
15˚
50˚
10˚
PRODUCT DIAGRAMS (CONTINUED)
Note:
Please refer to the specification insert sheet for performance details on individual cylinders.
† 180L & 210L Cylinders fitted with 1 ³/₄” BSP boss for an additional immersion heater, sold separately.
HORIZONTAL INDIRECT
C1
CONNECTIONS:
A
2
2mm Cold feed with deflector
in bottom of cylinder
B
22m Hot water outlet
C1
Immersion heater
C2
Secondary immersion heater
250 & 300 litre cylinders only
D
22mm Boiler coil connections
E
1
/
2
“ Temperature relief valve connection
(valve factory-fitted to cylinder)
F
22mm Secondary return – for cylinders with
a capacity of 210 litres and above only
G
Dry stat pocket
Capacity
(L)
Length
(mm)
Height with
Cradle & T&P
(mm)
Dia
(mm)
A
(mm)
B
(mm)
C2
†
(mm)
D
(mm)
E
(mm)
F
(mm)
G
(mm)
Immersion
Heaters
Fitted (
3kW)
180
1258
680
550
925
209
798†
483
346
n/a
609
1
210
1446
680
550
1213
209
898†
483
346
248
609
1
250
1696
680
550
1363
209
898
483
346
248
609
2
300
2009
680
550
1676
209
898
483
346
248
609
2
A
C2
G
D
D
Drain off
Measurements
from this point
E
B
F