CLEARANCES FOR ROUND FIREPIT (FP2085)
1. The round firepit (FP2085) cannot be built into a
combustible cabinet of any type. Only non-
combustible materials may be placed around firepit.
(eg. bricks, concrete, river rock, etc.)
2. Clearance to combustible side wall is 24” minimum.
Non-combustible walls 14” to side wall.
3. Minimum clearance to any ceiling with no overhang
is to be 7 feet from top of firepit.
4. Clearance to a combustible floor is 0”.
CLEARANCES FOR RECTANGLE FIREPIT (FP2785)
1. The rectangle firepit (FP2785) may be built into a
combustible enclosure. You must maintain minimum
enclosure dimensions of 32
1
/
2
” x 39
1
/
2
” I.D. The top
of enclosure must be of a non-combustible material
such as concrete board or wonder board.
2. Clearance to combustible side wall is 24” minimum.
Non-combustible walls 14” to side wall.
3. Minimum clearance to any ceiling with no overhang
is to be 7 feet from top of firepit.
4. Clearance to a combustible floor is 0”.
5. See Section 4.0 for assembly of enclosure.
3.0 INSTALLATION IN COMBUSTIBLE ENCLOSURE