ZCVRB47 –Vented Chase -Style 2 – OPENING WITH GRILL - Kingsman V46EG
⚠
NOTE:
If using
insulation in vented chase
(i.e. for outside wall), wall
board / drywall is required
to support all insulation.
Vented chase must be
clean and free of all debris
(i.e. loose insulation,
pieces of wood, etc.).
⚠
NOTE:
HEAT
CANNOT BE
DISCHARGED INTO THE
WALLS, FLOOR, OR
CEILING.
Heat must exit
through the required
vented chase opening
near the ceiling.
Sealed Enclosure Top
2-5/8" x 46-3/4"
Rough Opening
70”
MIN
Vertical Venting must use
Firestop Spacer (ZDVFS) or Attic
Insulation Shield and Sealant
SEALED ENCLOSURE
TOP VIEW
Optional Attic
Insulation Shield (ZDVAIS, ZDVAIS24)
2” MAX
52”
MIN
70”
Minimum
Enclosure
70”
MINIMUM
ENCLOSURE
47”
FRAMING
I.D.
VENTILATION PLATES MUST BE REMOVED.
Optional
Recess
Exterior wall is insulated and drywalled.
2-5/8" x 46-3/4"
Rough Opening
38-3/4”
2” MAX
Enclosure Top
to Grill Opening
2” MAX
2-5/8" x 46-3/4" Rough Opening
2-5/8" x 46-3/4" Rough Opening
Enclosure Top
must be sealed
24