MQRB5143 Combustible Enclosure Heights
Cold Climate Recommendation
When installing this fireplace against an exterior wall or chase, it is recommended that the outer walls be
insulated to conform to applicable insulation codes. Drywall must be installed over vapor barrier and
insulation material to prevent direct contact with the appliance.
See Thru or Single Sided Installation
Single Side Installation Only
[Steel Stud Framing Shown]
[Steel Stud Framing Shown]
For Propane Horizontal installations the venting must be a minimum of two
feet vertical off the flue before going horizontal.
51-1/2” Min Natural Gas
53-7/8” Min for Propane
21-5/8” Min for Natural Gas
24” Min for Propane
21-5/8” Min for Natural Gas
24” Min for Propane
The Wall Thimble Shield Z57WTS is required in
All Enclosures below 72” [Seventy
-Two Inches].
Place Wall Thimble Shield Z57WTS against the
Wall Thimble Immediately above the Vent. Install
the Wall Thimble Shield using [3] DT Screws.
51-1/2” Min Natural Gas
53-7/8” Min for Propane
The minimum
vertical
installation
height must be
adhered to.
Flex pipe venting
must be fully
stretched.