background image

Is

s

u

e

 N
o

7

0

4

2

8

0

WEST  ROAD  .  HARLOW
ESSEX  .  CM

20  2

BG  .  UK

i n f o @ g r e e n b r o o k . c o . u k    
w w w . g r e e n b r o o k . c o . u k

Dia:

2

2

.

Connect wiring in accordance with Dia:

2

.

ADJUSTING THE ‘LUX’ CONTROL

1

.

Turning Lux control fully clock wise, the sensor will operate in both daylight and darkness.

2

.

Turning Lux control fully anti-clockwise, the sensor will operate in darkness only.

3

.

Set control to operate at your required daylight level.

ADJUSTING THE ‘TIME ON’ CONTROL

1

.

Turning the time control fully anti-clock wise will set the on duration to 

10

s/- 

3

seconds.

2

.

Turning the time control fully clock wise will set the on duration to 

15

m/- 

2

minutes.

TROUBLE SHOOTING

Light not coming on 

Check that lamp is good.

Check there is nothing obscuring the PIR sensor.

Intermittent operation

Check there are no curtains that can move in the wind.

Check there are no heating vents nearby.

PLEASE KEEP THESE INSTRUCTIONS 

SAFE FOR FUTURE REFERENCE

N

L

L

3

.

Fold the metal springs of the sensor upwards and insert into the installation hole releasing 

springs, the springs will hold sensor in position.

4

.

To access the lux and time controls, insert a small flat-bladed screwdriver into the open 

release slot and twist, pull down until the controls are showing.

1

.

Turn ‘Time’control fully anti-clockwise and ‘Lux’ control fully clock wise refer to Dia:

4

.

TESTING

Dia:

4

2

.

Re-connect mains supply, allow 

30 

seconds for the sensor to warm-up, and then perform a 

walk-by in front of the sensor; lamp should turn on and stay on for approximately 

10

seconds,

and will go off if no further movement is detected.

TECHNICAL INFORMATION

Rated Voltage:

230

V

50

Hz

IP Rating:

IP

20

Ambient Light

:

<3-2,000 LUX (

Adj

)

Time Delay:

Min

10 

sec ± 

3

sec

Max 

15 

min ± 

2

min

Rated Load:

Max

800

W

Max 

400

W

Detection Range:

360

°

Detection Distance:

6M 

max (<

24

°C)

Working Temp:

-

20

° - + 

40

°C

Working Humidity:

<

93

%RH

Power Consumption:

0.5

W approx

Installation Height:

2.2 - 4

M

Detection Moving Speed:

0.6 - 1.5

m/s

/ LED

OD105 Ins.qxp_GU10  20/11/2015  12:19  Page 2