![Kingsford MASTER 15 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/kingsford/master-15/master-15_user-manual_1970656006.webp)
Installing
the Master 15/30/45
Moving your Master 15/30/45
Leveling your Master 15/30/45
Placing your Master 15/30/45
First Time Operating Instructions
•
Keep unit vertical at all times.
•
Never use cord to lift or pull.
•
Two people should carry to prevent injury.
•
Place unit on solid, firm and level ground.
It is important for the unit to be leveled in order to work properly. It can be raised or
lowered by rotating each of the feet on the bottom of the machine. If you find that the
surface is not level, rotate the feet until the unit becomes level You may need to make
several adjustments to level it. We recommend you use a carpenters level to check the
unit.
1.
Place a level on the top of the unit to see if the refrigerator is level from side to
side and tilted slightly towards the back. (Front higher than the back).
2.
Adjust the height of the feet as follows: Turn the leveling feet to the right to
lower that side of the refrigerator. Turning the feet left to raise that side of the
refrigerator.
3.
When leveling your unit, an easy trick is to pour a little water on the surface near
the drain and see if it drains properly. Keep making adjustments until you are
satisfied that the unit s draining properly.
•
WARNING: Do not store or install appliance outdoors.
•
WARNING: Unit is NOT DESIGNED FOR CABINET INSTALLATION.
•
We do not recommend installation on carpeted surface.
•
Do not install near heat source such as oven or fireplace.
•
Avoid placement in area with high moisture.
•
Place unit on solid, firm and level ground.
•
Leave at least 5 inches (12cm) between the back of the unit and the sides for
ventilation.
•
The unit must not be placed in direct sunlight.
•
Install the unit in a well ventilated area where the ambient temperature is above
50F and below 95F.
•
Adjust the leveling feet so that the unit is level.
•
Let the unit sit for 24 hours before plugging in the power cable and turning on.
•
Be sure to remove all packaging inside and outside.
•
Do not load a Master 15/30/45 until it reaches 34F-39F (10C-30C)
•
We do not recommend using extension cords. If you must use an extension cord
make sure it is UL/CUL, 3-wire grounding type appliance extension cord having
a grounding type plug and outlet and that the electrical rating of the cord be 115
volts and at least 10 amperes.
IMPORTANT
SAFEGUARDS
5