background image

6

SPECIFICATIONS

TROUBLESHOOTING

Model

CY1220-MT

Rated charge current

20A

Rated discharge current

20A

Rated voltage

12V/24V auto work

MPPT efficiency

Max:99%

Over load, short circuit protection

1.5 rated current

No load current

10mA

Over voltage protection

16V; ×2/24V

Voltage of stop charging

14.7V; ×2/24V

Discharge recovery voltage

12.0V; ×2/24V

Over discharge voltage

10.8V; ×2/24V

USB output

5V 1A

Working temperature

-35

~+55

Dimension of controller

131×99.5×29.5(mm)

L×W×H

) 

Weight

300g

PROBLEM

CAUSE

SOLUTION

Charging symbol not 
displaying even when the 
solar panel is in the sun

Solar has been improperly 
connected to the MPPT 
controller

Reconnect the solar panel 
ensuring that the positive 
and negative terminals are 
appropriately connected

Load icon is off

Battery is low, the load will 
start when the battery voltage 
is higher than 12.2V

Charge the battery

Load icon flashes quickly

Short circuit protection

System should reconnect 
automatically

The MPPT controller will not 
turn on

Battery is insufficiently 

charged

Charge the battery

Battery has been connected 
improperly

Check, and if necessary alter 
the battery’s connection to 
the MPPT controller

Содержание CY1220-MT

Страница 1: ...250W Folding Solar Panel USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USING THIS PRODUCT AKSR PN250W_04 V1 4 ...

Страница 2: ...r connect the Solar Panel directly without a controller to a battery or other load Tampering or modifying the solar panel controller or wiring will void warranty When transporting the solar panel firmly secure the panel so that it will not move around or collide with other objects Do not use the solar panel controller or wiring if it is damaged or compromised in any way Never tamper with or pull a...

Страница 3: ...nt at Pmax Imp 13 74A Open Circuit Voltage Voc 22 3V Short Circuit Current Isc 14 62A Normal Operating Cell Temp NOCT 47 2 C Maximum System Voltage 1000VDC Maximum Series Fuse Rating 20A Operating Temperature 40 C to 85 C Application Class Class A Weight 19 kg Dimensions 1060 x 1400 x 30mm ...

Страница 4: ... before connecting to the solar panel The solar controller will then illuminate DISCONNECTING STORING YOUR SOLAR PANEL Disconnect the solar panel off the battery before removing the battery clips off the battery Roll the wire neatly into the space behind the solar panel make sure not to twist or kink the wiring in an unnatural way Place the battery wire separately in the front pocket of the carry ...

Страница 5: ...nal load circuit connect positive and negative wires to the terminals with the lightbulb icon on the controller NOTE Ensure a fuse is used on battery positive wiring to prevent short circuits and potential damage to the unit or your vehicle INDICATOR INDICATED ITEM STATUS MEANING Solar Panel Steady ON Solar panel voltage is higher than the light control voltage OFF Solar panel voltage is less than...

Страница 6: ... 300g PROBLEM CAUSE SOLUTION Charging symbol not displaying even when the solar panel is in the sun Solar has been improperly connected to the MPPT controller Reconnect the solar panel ensuring that the positive and negative terminals are appropriately connected Load icon is off Battery is low the load will start when the battery voltage is higher than 12 2V Charge the battery Load icon flashes qu...

Страница 7: ...ailure does not amount to a major failure The benefits provided to you as the consumer by this warranty are in addition to other rights and remedies available to you under the law THE WARRANTY DOES NOT COVER a Any damage resulting from improper use b c The cost of removing and reinstalling the product d Travel and or other expenses due to customer s remote location e Transport charges and damage i...

Отзывы: