一、本机特点:
1.本充电器具有反接保护、过流保护、过压保护、短路保护功能;
2.电池保护:电池反接时,充电器自动关断,此时改正反接即恢复;
3.恒流、恒压充电过程自动转换,充满自动关断,绝无过充;
4.双指示灯显示:LED1⸺红灯亮为电源开启,红灯灭为电源关闭;
LED2⸺红灯亮为在充电中,绿灯为基本充满进入关断状态或输出端未连接
电池。
二、安装使用方法:
1.本充电器适配SPIRIT电池Plus,若要给其他电池充电,请先咨询电池厂商;
2.连接直流输出线到电池;
3.先检查交流电压等级是否相符,然后接上电源,LED1红灯亮;
4.本充电器具有过热保护功能,机内温度达到75℃(异常状态)整机自动关闭。
夏天,在临界状态下,会反复出现暂停5-10秒、再恢复工作数分钟的情况,这会
延长充电时间,此时,可采取外部辅助散热措施。
三、注意事项:
1.本充电器适用于SPIRIT电池Plus,电池充电曲线附后;
2.充电时,将充电器放置于少尘、干燥和通风的环境下;
3.铝质外壳作为散热器,不能被覆盖,避免过热;
4.本充电器风扇采用智能化控制,只有在LED2指示灯转红后才启动。
5.若充电器无法正常工作,请根据下列检查清单进行检查:
* 电池和充电器是否连接恰当?
* 电压水平是否合适?
* 充电器是否处于受保护状态?充电器是否已经进入保护模式?
排查故障并解决问题后,断电数秒钟,然后再重新连接。如果充电器仍然无法
正常工作,请立即联系厂商。若无厂商指导,请勿尝试解决问题。
6.请勿擅自拆卸充电器,否则保修将失效。
装箱单
快速充电器一台 输入电源线一根 使用说明书一份
Packing List
Fast Charger x1 Power Cable x1 User Manual x1
A. Features:
B. Operations:
C. Notices:
This charger is configured with reverse polarity, over current, over voltage and short-circuit
protections.
Reverse polarity protection: for chargers that use a relay for reverse polarity protection,
correct the connection and a chargeable battery are the prerequisites for reverse polarity
protection.
It implements automatic conversion for constant current charging stage and constant
voltage charging stage. It cuts off when fully charged without overcharging.
LED display: LED1 displays red only; LED2 displays red or green.
LED1 red shows AC power is on; LED1 off shows AC power is off.
LED2 red shows battery being charged; green shows either DC load is not connected or the
charger is complete (cut-off for lithium batteries).
The charger is configured for SPIRIT battery plus. The charging curve is attached.
The charger should be used in well ventilated, dry, particle free environment.
The aluminum case is an important means of heat dissipation, thus should not be covered.
Do not obstruct the wind/cooling channels.
The charger uses intelligent fans controlling system, which only start when LED2 turns red
(charging battery).
Should the charger not work proper, please follow the check list:
* is the battery and charger correctly connected?
* is the voltage level appropriate?
* is the charger in a protected state? Has the charger entered protection mode?
After troubleshooting and fixing the problem, disconnect power for a few seconds, then
reconnect to mains. If the charger still does not work properly, please contact
manufacutrer immediately. Do no attempt to fix the charger without technical support
from the manufacturer.
Opening the housing of the charger without prior written consent of the manufacturer
voids the manufacturer's warranty immediately.
This charger is configured for SPIRIT battery plus. To charge other batteries with this
charger, consult the manufacturer first.
Connect the DC cables to battery terminals.
Confirm the charger's AC input voltage level confroms to the local main/grid/AC
voltagelevel. Then connect the charger system to a wall socket strongly. When the LED1
displays red, it means the AC power is on
.
The charger has over-temperature protection, which shuts down the charger when the
internal temerature is above 75°C. In extreme heat conditions of equitorial countries, the
charger could enter into a prepetual cycle of suspension(5-10 seconds)and restart. In
such cases, it is necessary to take additional measures to reduce environment heat if delay
in charge completion is to be avoided.
1. The charger is configured for SPIRIT battery plus. The charging curve is attached.
2. The charger should be used in well ventilated, dry, particle free environment.
3. The aluminum case is an important means of heat dissipation, thus should not be covered.
Do not obstruct the wind/cooling channels.
4. The charger uses intelligent fans controlling system, which only start when LED2 turns red
(charging battery).
5. Should the charger not work proper, please follow the check list:
* is the battery and charger correctly connected?
* is the voltage level appropriate?
* is the charger in a protected state? Has the charger entered protection mode?
After troubleshooting and fixing the problem, disconnect power for a few seconds, then
reconnect to mains. If the charger still does not work properly, please contact manufacutrer
immediately. Do no attempt to fix the charger without technical support from the
manufacturer.
6. Opening the housing of the charger without prior written consent of the manufacturer voids
1. Standard KP chargers are configured with reverse polarity, over current, over voltage
and short-circuit protections.
2. Reverse polarity protection: for chargers that use a relay for reverse polarity protection,
correct the connection and a chargeable battery are the prerequisites for reverse polarity
protection.
3. It implements automatic conversion for constant current charging stage and constant
voltage charging stage. It cuts off when fully charged without overcharging.
4. LED display: LED1 displays red only; LED2 displays red or green.
1. This charger is configured for SPIRIT battery plus. To charge other batteries with this
charger, consult the manufacturer first.
2. Connect the DC cables to battery terminals.
3. Confirm the charger's AC input voltage level confroms to the local main/grid/AC
voltagelevel. Then connect the charger system to a wall socket strongly. LED1 displays
red, it means the AC power is on.
4. KP chargers have over-temperature protection, which shuts down the charger when the
internal temerature is above 75°C. In extreme heat conditions of equitorial countries, the
charger could enter into a prepetual cycle of suspension(5-10 seconds)and restart. In
such cases, it is necessary to take additional measures to reduce environment heat if
delay in charge completion is to be avoided.