OPERATING INSTRUCTIONS 

WHF Series Heater 

This heater is equipped with a thermal overload 
Smart Limit Protection which disconnects ele-
ments and motor in the event normal operating 

temperatures are exceeded. If thermal overload trips 
due to abnormal operating temperatures, thermal over-
load shall remain open until manually reset by turning 
the heater OFF for fifteen minutes. Inspect for any ob-
jects on or adjacent to the heater that may cause high 
temperatures. After inspecting the heater, keep the 
power to the heater off for 10 minutes to reset the SLP 
thermal protector. If the SLP thermal protector shuts 
the heater off again, immediately turn the heater OFF 
at the circuit breaker and inspect the heater for possible 
fan motor failure or dirt and lint on the heating ele-
ment.  Repeat the starting procedure. 

DO NOT TAMPER 

OR REMOVE THIS THIS DEVICE.

  

 
General information and Guidelines: 

This heater must be properly installed before it is used. 
DO NOT tamper with or change the operating of this 
heater. All service should be preformed by a authorized 
service representative. Only replace components with 
King approved replacement parts.  
 

Warning

: Clean Heater annually. Wait for heater to 

cool before removing grill. Use only a soft brush or vacu-
um on blow to clean heater. Re-attach grill before re-
applying power. 

Troubleshooting Table 

SYMPTOM 

PROBLEM 

SOLUTION 

Breaker Trips 

1.  Short Circuit 
2.  Overloaded Circuit 
3.  Improper Voltage 

1.     

 

2.     
3.     Verify the heater voltage matches the supply voltage. 
 

Heater not working  1.    No Power 

 
 
2.    Loose Connections 
3.    Defective Limit 

1.  Turn Breaker ON, turn thermostat ON, check that the breaker is position 

properly on panel bus-bar. A 2-Pole breaker must be connected to both bus-
bars (A&B phase) to produce 240V power. 

2.  Tighten wire connections. 
3.  By-pass the limit to test. If heater works, replace the limit. 

Heater Smokes 

1.    Oil on Element 
 
 
2.    Needs Cleaning 

1.  It is normal for the element to burn off some light finishing oil used in the 

manufacturing process when first energized. Open windows and allow room 
to vent until it stops, usually within a few minutes. 

2.  Remove any dust or dirt accumulations. 

Room Temperature 
does not match 
thermostat setting 

1.  Thermostat affected 

by another heat 
source. 

2.  Improper calibration 

1.    Sunlight or other heat sources can affect the thermostat. Move the thermo  
stat to another location or remove the heat source. 
 
2.    Remove cover and adjust calibration screw. 

Room Temperature 
swings from too hot 
to too cold 

1.  Defective or low 

quality thermostat 

1.    Replace with a better quality thermostat. Anticipated thermostats are fair-
ly accurate; an electronic thermostat is best. 

       SAVE THESE INSTRUCTIONS 

 

   Operation: 

1.  This heater must be properly installed in accordance 

with the National Electrical Codes (NEC) & local 
electrical codes before it is used. 

2.  After the electric heater has been completely in-

stalled, all thermostats should be turned to LOW or 
NO HEAT. Turn ON breakers, wait 3 to 5 minutes and 
check to see that the heaters are not operating. If 
operating, disconnect power and check for improper 
wiring. If none are operating then turn thermostats 
to highest position and wait 3 to 5 minutes. Check to 
see that all heaters are operating. Should any not be 
operating, disconnect power and check wiring. 

3.  Allow entire system to operate steadily for 1/2 hour. 

This should remove oily residue from manufacturing. 
(Some smoking may occur). 

4.  Select the setting for comfort on all thermostats. 

5. 

A safety limit control is provided to turn off the 
heater automatically if it is blocked or otherwise 
overheats due to an abnormal condition.

 DO NOT 

bypass or remove this safety device from the electri-
cal circuit-see Warning Figure 3 on page 2. During 
normal use, this safety control should not operate. If 
you find that this control is operating, make sure the 
heater is not being blocked. If it continues to cycle 
the heater off, disconnect power to heater and have 
it checked and repaired by a qualified electrician.

   

 