KING KC-7180V1-MS Скачать руководство пользователя страница 3

impoRtANt SAFEtY iNStRuctioNS 

RiSK oF ExpLoSioN oR FiRE

WhAt cAN hAppEN

It is normal for electrical contacts within the motor and pressure

switch to spark.

If electrical sparks from the compressor come in contact with

flammable vapors, they may ignite, causing fire or explosion.

Restricting  any  of  the  compressor  ventilation  openings  will

cause serious overheating and could cause fire.

hoW to pREVENt it

Always operate the compressor in a well ventilated area free of

combustible materials, gasoline or solvent vapors. If spraying

flammable materials, spray material at least 20 feet away from

the compressor. An additional length of hose may be required.

Store flammable materials in a secure location away from the

compressor.

Never  place  objects  against  or  on  top  of  the  compressor.

Operate compressor in an open area at least 18 inches away

from any wall or obstruction that would restrict the flow of fresh

air to the ventilation openings.

Operate compressor in a clean, dry and well ventilated area.

RiSK oF buRStiNg

WhAt cAN hAppEN

1. Failure to properly drain condensed water from the tank,  

causing rust and thinning of the steel tank.

2. Modifications or attempted repairs to the tank.

3. Unauthorized modifications to the unloader valve, safety 

valve or any other components which control tank pressure.

4. Excessive vibration can weaken the air tank and cause     

rupture or explosion.

Attachments & Accessories; Exceeding the operating pressure

of air tools can cause them to explode.

hoW to pREVENt it

Drain tank daily or after every use. If the tank developes a leak,

replace tank or get a new air compressor. Never drill into, weld

or make any modifications to the tank or its attachments.

The tank is designed to withstand specific operating pressures.

Never  make  adjustments  or  parts  substitutions  to  alter  the

factory set operating pressures.

For  essential  control  of  air  pressure,  you  must  install  a

pressure  regulator  and  pressure  gauge  to  the  air  supply

system.

RiSK oF buRNS

WhAt cAN hAppEN

Touching  exposed  metal  such  as  the  compressor  head  or

outlet tubes, can result in serious burns.

hoW to pREVENt it

Never touch any exposed metal parts on compressor during or

immediately  after  operation.  The  compressor  will  remain  hot

several  minutes  after  use.  Do  not  reach  around  protective

shrouds  or  attempt  maintenance  until  the  compressor  has

cooled down completely.

RiSK oF pRopERtY DAmAgE WhEN 

tRANSpoRtiNg compRESSoR

WhAt cAN hAppEN

Oil can leak or spill and could result in fire or breathing hazard,

serious injury or death can result. Oil leaks will damage carpet,

paint or other surfaces in vehicules or trailers.

hoW to pREVENt it

Always  place  compressor  on  a  protective  mat  when

transporting to protect against damage to vehicule from leaks.

Remove compressor from vehicule immediately apon arrival.

1) Read and understand instruction manual before attempting to install

and  use  compressor.  Be  thoroughly  familiar  with  the 

operational controls and proper use.

2) All electrical and safety codes must be followed to ensure operator 

safety.

3)  Applications  requiring  air  free  of  oil  or  water  should  have  the               

appropriate filters/water traps installed in the pressure system.

4) Wear safety glasses.

5) Do not operate if any part is damaged during shipping, handling or 

use, have the part replaced or repaired before attempting to use.

6)  Never  operate  the  compressor  with  the  belt  guard  removed,  this 

compressor can start automatically without warning. Personal injury 

or property damage could occur from contact with moving parts.

7)  Never  attempt  to  modify  or  adjust  the  ASME  safety  valve.  The           

safety valve must be kept clean and free from paint or any other    

type of accumulation.

8) Never attempt to repair or modify air tank. Welding, drilling or any 

other modification will weaken the air tank resulting in damage from 

rupture or explosion.

9) Drain water from tank on a regular basis. Tanks rust from moisture 

build-up which weakens the air tank.

This air compressor and other components used make up a high pressure system, the following safety rules and guidelines should be followed

when using, cleaning or servicing.

Содержание KC-7180V1-MS

Страница 1: ...iNStRuctioN mANuAL moDEL Kc 7180V1 mS COPYRIGHT 2013 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC high output StAtioNARY 7 5 pEAK hp 80 gALLoN AiR compRESSoR 11 2014 ...

Страница 2: ...d lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take advantage of this limited warranty return the product at your expense together with your dated proof of purshase to an authorized King Canada service center Contact your retailer or visit our web site...

Страница 3: ...y system RiSK oF buRNS WhAt cAN hAppEN Touching exposed metal such as the compressor head or outlet tubes can result in serious burns hoW to pREVENt it Never touch any exposed metal parts on compressor during or immediately after operation The compressor will remain hot several minutes after use Do not reach around protective shrouds or attempt maintenance until the compressor has cooled down comp...

Страница 4: ...formation below Warning Do not attempt to hard wire this compressor yourself unless you are a qualified electrician Overheating short circuiting and fire damage will result from inadequate wiring Electrical wiring codes local or provincial may differ from area to area Source wiring plug and protector must be rated for at least the amperage and voltage indicated on the main technical nameplate Use ...

Страница 5: ...ut iNto SERVicE AFtER REpLAciNg thE chEcK VALVE AND WhEN A piStoN oR A cYLiNDER SLEEVE ARE REpLAcED 1 Make sure the pressure switch lever A Fig 3 is in the OFF position 2 Make sure the compressor is properly wired to electrical source and grounded if a power cord was installed plug the power cord into a grounded 240V branch circuit receptacle 3 Make sure the oil level in the crankcase reaches the ...

Страница 6: ...e power to the automatic pressure switch and OFF to remove power at the end of each use pRESSuRE SWitch c Fig 9 The pressure switch automatically starts the motor when the tank pressure drops below the factory set Cut In pressure It also stops the motor when the air tank pressure reaches the factory set Cut Out pressure ASmE SAFEtY VALVE D Fig 9 If the pressure switch does not shut off the air com...

Страница 7: ... be in the centre of the red dot of oil sight glass 2 Drain condensation from tank 3 Check for any unusual noise or vibration 4 Be sure all nuts and bolts are tight monthly 1 Inspect air system for leaks by applying soapy water to all joints Tighten those joints if leakage is observed initial oil change must be done after the first 100 hours 1 Once initial oil change is done after 100 hours of ope...

Страница 8: ...sure Restricted air filter Wrong oil viscosity Oil level too high Crankcase breather valve malfunction Worn piston rings Piston rings not seated CORRECTIVE ACTION Check voltage or eliminate extension cord or reset Check wiring connections Wait for motor to cool then press the reset button restart Drain tank of air pressure Check valve manually by pulling If condition persists replace Close drain c...