background image

Connection Diagram for Wall Mounted Thermostat
1. Connect the two red thermostat wires to the black  
  and white power supply wires. 
2. Connect the two black thermostat wires to the  
  black and white heater wires.
3. Connect all the bare groundwires together.

Connection Diagram when using a Wall Thermostat
1. Connect power supply wires from wall thermo- 
  stat as shown.
2. Black and white supply wires can be connected  
  to the heater in reverse order. For simplicity the  
  most common method is shown.
3. Connect bare groundwire to green groundwire.

Connection Diagram for BKT-2 Thermostat
1. Mount thermostat per instructions. 

3. Connect the two black thermostat wires to the two heater wires.

2. Connect the two red thermostat wires to the 

4. Bare groundwire to green groundwire.

    black and white supply wires.

Cut one wire to Apply Power to

LEFT SIDE

Cut one wire to Apply Power to

RIGHT SIDE

Supply Power Connection

LEFT SIDE

Power Supply Connection

RIGHT SIDE

Built-in (BKT-2) Diagram

LEFT SIDE

Built-in (BKT-2) Diagram

RIGHT SIDE

SUPPLY WIRES

HEATER WIRES

BLACK WIRE
RED WIRE
BARE GROUNDWIRE
WHITE WIRE

WIRE COLOR CHART

WIRING INSTRUCTIONS FOR DOUBLE POLE THERMOSTATS

KING  ELECTRICAL  MFG.  CO.

 

·

 

9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · TEL:  206.762.0400 · FAX:  206.763.7738

BKT-2

Double Pole

D22

K602
HE-2

HET-2

CB.indd : 2/09

Instructions for Left or Right Side Wiring Connection
1. 

Caution:

 Do not cut both factory splice caps  

  on left side! You need only two wires for power  
  connection.
2. Heater can be wired from either side - wire one  
  side only.
3. Cut only one factory splice cap or loop wire as  
  shown.
4. This leaves two wires for power connection. 

Содержание CB SERIES

Страница 1: ...w away from heater Refer to clearance diagram for drapes Do not install heater below an electri cal outlet or against vinyl wallpaper paperboard or low density fiberboard surfaces Do not recess mount heater Do not mount heater vertically Do not store flammable liquids in vicinity of the heater Installation must comply with applicable national and local electrical codes Protect electrical supply wi...

Страница 2: ...ct power supply wires from wall thermostat as shown 2 Black and white supply wires can be connected to the heater in reverse order For simplicity the most common method is shown 3 Connect bare groundwire to green groundwire Connection Diagram for BKT 1 Thermostat 1 Mount thermostat per instructions 4 White supply wire to heater 2 Red thermostat wire to black supply wire 5 Bare groundwire to green ...

Страница 3: ...t wires to the 4 Bare groundwire to green groundwire black and white supply wires Cut one wire to Apply Power to LEFT SIDE Cut one wire to Apply Power to RIGHT SIDE Supply Power Connection LEFT SIDE Power Supply Connection RIGHT SIDE Built in BKT 2 Diagram LEFT SIDE Built in BKT 2 Diagram RIGHT SIDE SUPPLY WIRES HEATER WIRES BLACK WIRE RED WIRE BARE GROUNDWIRE WHITE WIRE WIRE COLOR CHART WIRING IN...

Страница 4: ...hold up to the heat but will not last as long as the original baked enamel finish Q How much heat do I need A A general rule of thumb is 10 Watts for every square foot of floor space For example A 10 x 10 room is 100 ft 10 w ft x 100 ft and would require 1000 Watts of heat If you live in a cold climate or if the room has a ceiling height above 8 feet use up to 15 w ft KING ELECTRICAL MFG CO 9131 1...

Отзывы: