background image

B.  With In-floor Cleaners

A.  With High GPMS
Install T-fittings exactly as shown.

C.  Pool and Spillover Spa Combination

TO POOL

TO SP

A

3-WAY

SPARCO
CYCLER

CHECK VALVE

PUMP

TO 

POOL

SPARCO
CYCLER

CHECK
VALVE

For Proper Performance

SPARCO
CYCLER

PUMP

3-WAY VALVE

11

SUCTION
FROM
POOL/SPA

1) 

Make sure back pressure Is between

3 and 8 psi

Higher back pressures could result in over
chlorination. Lower back pressures could
result in under chlorination. Adjust eye
ball fittings in the return jets to a larger
size to decrease back pressure or smaller
size to increase back pressure. Contact
your dealer to have your back pressure
tested to ensure it is between 3 and 8 psi.

2) Recommended flow rates for in
ground unit is 20-80 gpm.

3) Determine possible high-flow
situations that require a special
installation such as:

A.  Water flow is higher than 80 gpm.

B. In-floor cleaner is included with pool.

C.  Pool and spa combination with common
equipment.

NOTE:  Over chlorination or damage to the
Sparco Cycler or other equipment could
result if these special installations are not
used in these situations.

SUCTION
FROM
POOL/SPA

IN-FLOOR
VALVE

POOL WATER LEVEL

AUTOMATIC

WATER

TREATMENT

SYSTEM

Содержание SPARCO CYCLER

Страница 1: ...Sparco Cycler Pool Care for Above Ground or In Ground Pools INSTRUCTION MANUAL CYCLER MODEL 5510 ...

Страница 2: ...l O Rings 6 Replacing Cap O Ring 6 Replacing Knob 6 Winterizing 7 Parts List 7 In Ground In Line Installation 8 Above Ground Filter Installation 9 Above Ground Base Installation 10 For Proper Performance 11 Warranty Back Page For information on King Technology s entire product line visit our website at www kingtechnology com 2 ...

Страница 3: ...turer s directions A dirty filter will slow the flow of water which could hamper proper circulation After your pool is up and running smoothly continue to test your water for pH total alkalinity and chlorine and maintain its balance by adding any necessary adjustment products see your dealer for details Before beginning with any pool care program you must first balance your pool water Take a water...

Страница 4: ... 23 NR This pump size is not recommended for this size pool 7 000 18 9 000 21 12 000 24 18 000 25 000 Gallons Diameter 30 000 RECOMMENDED FLOW RATES Above ground 20 60 gpm In ground 20 80 gpm 1 Set control dial by matching up the parameters of your pool on the chart below This is a starting point only and may need to be adjusted to fit your individual pool needs See below for adjusting directions ...

Страница 5: ...cap by hand only DO NOT OVERTIGHTEN DO NOT USE CAP TOOL TO TIGHTEN CAP FOR REMOVAL ONLY Turn off pump Turn dial to Minimum This reduces the flow of water into the unit when the cap is open so isolation valves are unnecessary Turn chamber over and shake slightly until tablets fall into tower areas Avoid sparks open flame or smoking when handling the chamber Insert chamber into Sparco Cycler lining ...

Страница 6: ...iers find the snap ring tail located at approximately the five o clock position under the control dial Pull down and out of the groove Using a large screwdriver loosen the control dial Carefully pry the dial until it pulls out Insert the non lipped end of snap ring into the groove opening beginning at the 5 o clock position and push it up so that it threads itself around the control dial Using a s...

Страница 7: ...GRAM PARTS LIST REF PART NUMBER DESCRIPTION QTY REQ 1 2 01 22 9412 Cap w O Ring 1 2 01 22 9920 Cap O Ring 1 3 N A Body 1 4 01 22 9480 Pressure Relief Valve 1 5 6 7 01 22 9441 Control Dial with O Rings 1 6 7 01 22 9450 Control Dial O Ring Set 1 8 9 01 22 9941 Knob with O Ring 1 10 01 22 8870 Cap Control Dial Tool 1 11 01 22 9970 Silicone Lubricant 1 12 01 22 9980 Chamber Cutting Tool 1 Remove chamb...

Страница 8: ... NOT OVER TIGHTEN Following PVC cement directions brush PVC cement on ends of pipe and the inside of bushings Insert PVC pipe into bushings Hold in place 5 to 10 seconds to bond Installing a corrosion resistant check valve is recommended Hacksaw Do NOT install an in line Sparco Cycler off line Install after all equipment and as far as possible from heater Do NOT install in copper pipe as chemical ...

Страница 9: ...rovided with filter Pipe Wrench Two 2 threaded by 1 1 2 threaded bushings Following pipe thread sealant directions brush sealant on filter threads Screw a bushing into each port of Sparco Cycler and hand tighten Completely tighten turning 1 to 2 revolutions with wrench DO NOT OVERTIGHTEN DO NOT USE TAPE as the threads on these units are not suitable for this use and leaking or bushing failure coul...

Страница 10: ...LS NEEDED Pipe Thread Sealant Two Hose Adapters 1 1 2 X 1 1 2 X 1 1 4 Two Sections of 1 1 2 Flex Hose one provided with filter For better stability Sparco Cycler may be mounted on a base using Phillips pan head screws Screwdriver Wrench Two 2 Threaded by 1 1 2 Threaded Bushings Following pipe thread sealant directions brush sealant on to Sparco Cycler threads in both ports Brush sealant on the thr...

Страница 11: ...ets to a larger size to decrease back pressure or smaller size to increase back pressure Contact your dealer to have your back pressure tested to ensure it is between 3 and 8 psi 2 Recommended flow rates for in ground unit is 20 80 gpm 3 Determine possible high flow situations that require a special installation such as A Water flow is higher than 80 gpm B In floor cleaner is included with pool C ...

Страница 12: ...ool dealer or distributor for further information concerning shock treatments B Control dial settings in excess of the recommended setting levels for trichlor can result in excess sanitizers being discharged into the pool This can result in bleaching or discoloration of areas around the pool inlet or in some cases bleaching or discoloration of the entire pool liner or paint C Excess trichlor in th...

Отзывы: