Page 7 of 22
King Pigeon Hi-Tech. Co., Ltd.
Ver 1.0
GSM/GPRS/3G/4G/Cloud
Network Fault Monitoring Alarm
7. Reset the unit
(1) Switch on the device,press and hold RESET button for 3 seconds,after power indicator flash 3 times ,the device
will reset successfully.
(2) Sending SMS command
”
pRESET
”
,receive returns SMS
“
Reset successfully
”
,means device is reset
successfully.
8. Configuration software
When connecting to the configuration software for the first time, connect the device to a router that enabled the
DHCP automatic assign IP function.if the network connected to the device cannot automatically assign an IP,the
device will use the following default network parameters after waiting for 1 minute:IP address 192.168 .1.111,
subnet mask 255.255.255.0, gateway address 192.168.1.1.At this time, please set the computer network
parameters to other IP addresses in the same network segment.if the device is directly connected to the computer,
please use a crossover network cable,and configure the computer network parameters before connecting the
device.
8.1. Search Device
Search Device:
Click to search for all terminal devices in the LAN,Note that the computer and the device must be
on the same network segment in the same LAN, and the subnet mask must be 255.255.255.0).
Enter:
Click to enter the configuration interface of the corresponding device;
Language:
Can switch configuration software language to Chinese or English.
Notice:
If the device cannot be searched, but the fixed IP of the device has been set, you can directly enter the fixed IP of the device in
the IP input field.
8.2. Selection Description
Device Password:
Default is 1234
Connection :
Only the password is correct can connect successfully, and can be configured after connection.
Read:
Read the current configuration of the device and read it before editing the parameters.
Save:
Write edited parameters to the device.