Pages 41 Total 58
Shenzhen King Pigeon Hi-Tech Co.,LED
Ver 1.2
PLC Data acquisition protocol conversion gateway
-D225
Note: To modify the configuration, you need to log in to the configuration software, select the
device to be configured before configuring
Operation instructions: (1) After logging in by selecting the device to be configured (in this example,
double-click the IP address: 192.168.1.250 to log in),PLC selection is FX3U, so choose Mitsubishi
FX3U for device protocol, serial port 1 (232) for device link, (2) choose Jingeyun 3.0 for server
protocol, (3) choose Jingeyun 3.0 for server protocol The system defaults and does not need to be
modified. (4) For the registration code, please contact the sales representative of King Pigeon. The
heartbeat packet and heartbeat response can be left blank or filled. According to your own needs,
the company's Jin Ge 3.0 platform is fixed The heartbeat packet and the heartbeat response packet
are respectively: "req" and "res", (5) The serial port configuration is filled in according to the serial
port parameters of FX3U, (6) The IP address is modified according to your own needs, (7) After the
configuration, click "Save parameters" ", after the save is successful, click the "Restart" button to
restart or the D225 device is powered off, power on again, and restart.
5.4.2
King Pigeon (KPIOT 3.0) Platform configuration
5.4.2.1
New device
For the login user name and password of the company
’
s KIPIOT 3.0 platform, please contact the
sales representative of Golden Pigeon Technology. After logging in to the Golden Pigeon 3.0
platform, click the "Add Device" icon for quick access on the "Homepage" or click "Device
Management". New equipment" to configure some information of D225 equipment and set up
D225 equipment to collect PLC data points, as shown below