background image

UPLOADING REQUIRED 

FIRMWARE

Safety Guard Firmware- Required Upload

 

Note:

 The Voyager DVR Drill Press (model 58006) does NOT come with the necessary 

firmware to operate this Safety Guard with Limit Switch. The firmware version of the HMI 
can be upgraded via USB cable accessory (included with the Voyager DVR Drill Press) 
and a PC computer with internet access. Follow these basic instructions for uploading 
required firmware. 
 
1) Go to www.teknatool.com web site. 
2) Click on “Support” tab (1), then click on “Upgrade Your DVR Firmware” tab (2) as shown 

below. 

3) In order to upload new Firmware, an Uploader Software must be downloaded first. 

Download software (3), uncompress folder and install software. 

4) Download the required firmware for the Voyager DVR called EU - R2P05x CG - 2018-

05-02 (4). Once downloaded, uncompress folder to access Firmware file. 

5) Connect the USB cable (included with the Voyager DVR Drill Press) from your      com-

puter to the plug found 
under the control panel. 

6) Launch Uploader      

Software. Press F1 then 
ON buttons on control 
panel to establish      
communication. LCD 
will indicate “SJM 
Device in DFU Mode”. 

7) From the menu, click on 

“choose” and select the 
Firmware file you 
uncompressed earlier. 

8) Click “upgrade”. The 

firmware upgrade will 
begin loading, and you will be notified when the process has finished. Installation is      
finished. 

 

Firmware Test 

At this point, it is important to make sure the firmware upgrade was successful by testing 
the safety guard. Turn machine on, open the safety guard. The machine must stop and 
the LCD screen will indicate “Safety Guard Open”. The drill press will not be able to start 
again until the safety guard is completely closed.

PARTS DIAGRAM & PARTS LISTS

 

Refer to the Parts section of the King Canada web site for the most updated parts  
diagram and parts list.

Отзывы: