ASSEMBLY & OPERATION
21. Install magnetic switch (A) Fig.16 to the left column (left column has an
opening (B) to insert magnetic switch quick connect cord). Remove the
magnetic switch cover (C) by removing the two screws (D) that secure it
to the switch.
22. Install magnetic switch to column as shown in Fig.16 using two pan head
screws and hex. nuts.
23. Reinstall the magnetic switch cover and connect the magnetic switch quick
connect cord (E) Fig.16 to the motor quick connect cord (F).
24. Install the air inlet (A) Fig.17 to the intake housing (B). Secure the air inlet
using the pan head screw (C).
OPERATION
MAGNETIC SWITCH
The magnetic switch (A) Fig.18 is located on the left column. The ON button
(B) turns the cyclone dust collector motor “ON”. This magnetic switch is
equipped with an Emergency Twist OFF (Stop) button (C) which turns the
cyclone dust collector motor “OFF”.
To reset the magnetic switch and to turn the machine on again, first push the
Emergency Twist OFF (Stop) button in, then twist it clockwise until it pops out.
The magnetic switch ON button will only work once the OFF button has poped
out.
USING THE REMOTE CONTROL
All three Cyclone Dust Collectors come with a remote (A) Fig.19 which can be
used to turn the machine On or Off.
Note: The remote will not work until the Emergency Twist Off (Stop) button on
the magnetic switch is twisted clockwise and has popped out. The remote will
only work once the Emergency Twist Off (Stop) button has poped out.
To turn the machine On, press the green button (B) Fig.19. To turn the
machine Off, press the red button (C).
FIGURE 16
FIGURE 17
FIGURE 18
FIGURE 19