Moisture in compressed air

When humidity is high or when the compressor is in continuous use for an extended period of time, this moisture will collect in the air tank.
When using a spray gun or sandblast gun, this water will be carried from the tank through the hose and out of the gun as droplets mixed with
the spray material. This will cause water spots in a paint job, especially when spraying other than water based paint. If sandblasting, it will cause
the material to cake and clog the gun, rendering it ineffective. An optional air control unit with dirt and moisture removal should be used to pre-
vent these undesireable results.

MAINTENANCE

Before doing any maintenance or adjustments to your air compressor, the following safety precautions should be taken:
- Turn power off (turn circuit breaker off or unplug power cord), drain air tank of pressure.

After Use: 

1) Set the “OFF/AUTO” lever to “OFF”.
2) Pull ring on safety valve (D) Fig. 8, allowing air to bleed from the tank until tank pressure is approximately 20 PSI. Release safety valve ring.
3) Drain water from air tank. Open drain valve (A) Fig.9, turn it clockwise to open.

WARNING!

: Water will condense in the air tank. If not drained water will corrode and weaken the air tank causing a risk of air tank rupture. 

NOTE: 

If drain valve is plugged, pull ring on safety valve (D) Fig.8, and hold until all air pressure has been released. The valve can then be

removed, cleaned, and reinstalled.
4) After the water has been completely drained, turn drain valve counterclockwise to close.

Daily or before each use

1) Check oil level. Oil level must be in the centre of the red dot of oil sight glass.
2) Drain condensation from tank.
3) Check for any unusual noise or vibration.
4) Be sure all nuts and bolts are tight.

Monthly

1) Inspect air system for leaks by applying soapy water to all joints. Tighten those

joints if leakage is observed.

Initial oil change must be done after the first 100 hours

1) Once initial oil change is done after 100 hours of operation, change oil every

300 hours or 3 months, which ever comes first. See changing oil instructions.

2) Replace oil more often if used near paint spraying operations or in dusty

environments.

CHANGING OIL (ORIGINALLY FILLED WITH SAE 20W OIL (ISO 68)

To change oil, oil must be drained from the crankcase by removing oil drain bolt
(A) Fig.11. Drain oil and replace oil drain bolt. To fill the crankcase with oil, first unscrew and remove oil fill cap (B), pour air compressor oil
(approx. 900ml of SAE 30 weight non-detergent oil) into oil opening until the oil level reaches the red dot at the centre of the oil sight glass (C).
Reinstall the fill cap (B).

KEEP COMPRESSOR CLEAN

Periodically blow out all air passages with dry compressed air. Clean all parts with
a soft damp cloth. 

CAUTION

: Wear safety glasses while using compressed air.

REPLACING/TENSIONING DRIVE BELT

If the drive belt needs tensioning, the belt should be adjusted so when pressure
is applied in the centre, there is approximately 1/2” slack. See Fig.12.

1) To install a new belt, remove belt guard. Loosen motor mount bolts and slide

motor towards the pump, remove belt.

2) Install proper replacement belt, slide motor away from pump to provide

recommended tension, align pulleys and fasten motor mount bolts.

3) Reinstall belt guard. Belt tension should be checked after 20 hours of

operation. Check belt tension monthly thereafter.

FIGURE 11

FIGURE 12

Содержание KC-6160V1

Страница 1: ...INSTRUCTION MANUAL MODEL KC 6160V1 COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC STATIONARY 6 5 PEAK HP 60 GALLON AIR COMPRESSOR...

Страница 2: ...lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take a...

Страница 3: ...system RISK OF BURNS WHAT CAN HAPPEN Touching exposed metal such as the compressor head or outlet tubes can result in serious burns HOW TO PREVENT IT Never touch any exposed metal parts on compressor...

Страница 4: ...the grounding screw on the pressure switch See grounding information below Warning Do not attempt to hard wire this compressor yourself unless you are a qualified electrician Overheating short circui...

Страница 5: ...e compressor is properly wired to electrical source and grounded if a power cord was installed plug the power cord into a grounded 240V branch circuit receptacle 3 Make sure the oil level in the crank...

Страница 6: ...D FIG 8 If the pressure switch does not shut off the air compressor at its cutout pressure setting the safety valve will protect against high pressure by popping out at its factory set pressure sligh...

Страница 7: ...level Oil level must be in the centre of the red dot of oil sight glass 2 Drain condensation from tank 3 Check for any unusual noise or vibration 4 Be sure all nuts and bolts are tight Monthly 1 Inspe...

Страница 8: ...ure Restricted air filter Wrong oil viscosity Oil level too high Crankcase breather valve malfunction Worn piston rings Piston rings not seated CORRECTIVE ACTION Check voltage or eliminate extension c...