LUbRICATION
Lubrication Guide for Industrial Planer KC-520C
No. Position Interval Suitable Types of Lubricants Fig. No.
1 Chain Frequently Grease 30
2 Gear Box When operated more than 2,500 hours HD-100, Mobil Gear 627, Shell Omala 100, 30
ESSO Spartan EP-1004
3 Rollers Frequently SAE-30 31
4 Worm Gear Frequently Grease 31
5 Lead Screw Frequently Grease 31
6 Column Frequently Clean and SAE-30 31
7 Chain Frequently Grease 32
8 Bushing Frequently SAE-30 31
FIGURE 30
FIGURE 31
FIGURE 32
LUbRICATION GUIDE FOR GEAR bOX
The gear box lubricant must be replaced every 2,500 hours of operation.
Suitable lubricant is multi-purpose gear box lubricant.
To replace lubricant:
1. Remove the drain plug (A) Fig.30 and filter cap (B), drain dirty oil thorough-
ly.
2. Tighten the drain plug (A).
3. Fill with clean lubricant through hole (B).
4. Tighten the filler cap (B).
Below you will find lubrication instructions and maintenance intervals to maintain your Planer in good working order. Failure to upkeep your
Planer as prescribed on this page will reduce its life span.