Page 9
14. Remove blue protective sheet and red “position to rear” sticker from the dome unit.
11. Run wires from the back of the dome unit to the roof edge, then along edge to location where
wiring will be fed into the vehicle. If installing an optional auxiliary receiver, run auxiliary coax
to location where it will enter the vehicle. Secure wiring to roof every 12-18 inches
(Fig. 10)
.
12. Drill 3/4” hole through the roof and into the cabinet where receiver is stored. Feed wiring
down through hole. Seal opening with roof compatible sealant so that it is completely
waterproof (inside and outside of the 3/4” hole). Repeat for auxiliary coax if present.
13. Fasten cable entry cover to roof. Seal mounting holes, perimeter of cover and cable opening
so they are completely waterproof.
Fig. 10
TYPICAL ROOF INSTALLATION - OVERHEAD VIEW
IMPORTANT!
Sealant must be roof compatible.
IMPORTANT! SEALANT MUST BE ROOF COMPATIBLE.
Installer is responsible for determining proper roof compatible fasteners for cable entry cover.
Roof holes for cables must be sealed so they are completely waterproof. Mounting holes,
perimeter of cable entry cover and cable opening of cable entry cover must be sealed so they
are completely waterproof.