WARNING! To prevent permanent damage to your water pump, you MUST assemble
all hoses (not supplied), hose adaptors and strainer basket if needed, prime the water
pump and have the inlet hose submerged in water before starting water pump engine.

CONNECTING HOSE ADAPTORS TO PUMP INLET AND OUTLET;

This water pump comes with 4 hose adaptors and 4 rubber gaskets, these items allow you
to connect regular hoses with a 2” diameter without threaded ends (not supplied, see your
local hardware store) to the inlet or outlet of the water pump. The following assembly steps
apply to both the water pump inlet and outlet;
1)

Unscrew and remove nut connector (A) Fig.5, place hose adaptor (B) into the nut

connector, then press rubber gasket (C) on the inside of the nut connector, against the
hose adaptor. Fig.5 shows the assembly of the outlet nut connector.

2) Screw the entire assembly onto the outlet thread and tighten securely. Your water pump

will look like Fig.6 once both hose adaptors are assembled. Make sure they are both
tightened properly to avoid water leaks.

CONNECTING HOSES TO HOSE ADAPTORS

This water pump does not include water hoses and you will need to purchase 2 hoses
of the required length having a diameter of 2”. It is required to get a reinforced hose with
or without 2” NPT to assemble to the inlet (2” NPT hoses do not require hose adaptors,
see Fig.7), a non-reinforced hose will collapse on itself from the suction force and prevent
water flow, which could cause damage to the engine and water pump machine seal.
1) If you purchased a 2” NPT reinforced hose, screw it onto the the inlet thread as

shown in Fig.7.

2) If you purchased a non-thread 2” reinforced hose, attach it to the inlet hose adaptor

and fasten hose as shown in Fig.8 and explained in the following steps.

ASSEMBLING & CONNECTING STRAINER BASKET TO INLET HOSE

If this water pump is used to pump water from a river, it is very important to install the
strainer basket to the inlet hose to prevent suction of rocks or weeds. Fig.7 shows the
pump inlet and hose. Attach strainer basket to the other end of inlet hose.
1)  Fasten the strainer basket (A) Fig.8 to the strainer basket adaptor (B) using 4 hex.

bolts and hex. nuts as shown. 

2)  Place a wire clamp (C) over the end of the inlet hose (D)(it may be required to cut the

2” NPT off to install the adaptor), then slide both over the strainer basket adaptor.

3) With the hose completely positioned over the strainer basket adaptor, position the

wire clamp over the ribbed portion of the strainer basket adaptor and tighten wire
clamp screw (E) using a flat head screwdriver. Make sure to tighten properly to avoid
water leaks.

PRIMING THE WATER PUMP

Warning! Never turn the engine on until you have primed the water pump. This means
adding water inside the water pump, up close to the rim of the priming cap. Make sure
all pre-operation and assembly instructions have been followed before priming water pump.
1)  Unscrew and remove priming cap (A) Fig.9, fill the water pump with water all the way up close to the priming cap thread.
2) Reposition priming cap and tighten.

INSPECTION & SET-UP

BEFORE STARTING ENGINE

Figure 5

Figure 6

Figure 7

Figure 8

Figure 9

Содержание Power Force KCG-2PG

Страница 1: ...CTION MANUAL COPYRIGHT 2006 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL KCG 2PG Read this manual Do not attempt to operate this water pump until you have read and understood the safety operation and maintenance instructions ...

Страница 2: ...ability caused by shipping improper handling improper installation improper maintenance improper modification or the use of accessories and or attachments not specifically recommended Repairs necessary because of operator abuse or negligence or the failure to install operate maintain and store the product according to the instructions in the owner s manual Damage caused by cold heat rain excessive...

Страница 3: ...p in areas where the temperature exceeds 40 C ambient such as storage rooms or garages can interfere with its proper ventilation features causing overheating and possible ignition of the materials or buildings Operate water pump in a clean dry well ventilated area a minimum of four feet from any building object or wall DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AREA RISK OF BREATHING INHALATIO...

Страница 4: ...ne The fuel shut off lever must be positioned completely to the right before starting the engine 13 Choke lever Once the engine is started it is necessary to gradually move the choke lever to the left see instructions futher in this manual 14 Throttle lever Regulates the speed of the engine it is recommended to move the throttle lever completely to the right to obtain maximum results 15 Air cleane...

Страница 5: ...This water pump comes without fuel in the fuel tank and will require clean unleaded gasoline with a minimum of 87 octane Do not mix oil with gasoline Fuel tank capacity 3 6 Litres You can check the fuel level by undoing the fuel cap A Fig 2 by turning it counter clockwise and making a visual inspection If it is necessary to add fuel first make sure the engine is OFF and fill gas tank with gasoline...

Страница 6: ...to the engine and water pump machine seal 1 If you purchased a 2 NPT reinforced hose screw it onto the the inlet thread as shown in Fig 7 2 If you purchased a non thread 2 reinforced hose attach it to the inlet hose adaptor and fasten hose as shown in Fig 8 and explained in the following steps ASSEMBLING CONNECTING STRAINER BASKET TO INLET HOSE If this water pump is used to pump water from a river...

Страница 7: ...ever C Fig 10 a little from the left side towards to the right side 5 Pull the recoil starter handle D Fig 10 until resistance is felt then pull it out with a rapid full arm stroke Let the starter rope rewind slowly repeat if necessary until the engine starts 6 Once the engine starts gradually move the choke lever all the way to the right On position It is recommended to warm up the engine for 3 m...

Страница 8: ...t off valve lever A Fig 10 to the left Off position and dismantle the fuel filter cup A Fig 15 attached to the caburetor by turning it counterclockwise 2 Remove the fuel filter inside clean both the fuel filter and the cup If the rubber seal between the fuel filter and fuel filter cup seems damaged replace it 3 Reinstall all parts in the reverse order Water pump Storage If you plan on storing your...

Страница 9: ...d supply Change of engine oil Check for fuel and oil leaks Check and cleaning the air cleaner Check and cleaning of spark plug Check and cleaning of fuel strainer Remove of carbon in combustion chamber Check and adjustment of valve clearance Replace the fuel lines Every Operation Every 20 hours Every 50 hours Every 100 hours m m m m m m m m l l 2 years or when necessary INSPECTION TROUBLESHOOTING ...

Страница 10: ... head is too high and causing cavations Check the suction head and lower the position of the pump Sudden stop of flow Suction head is too high and causing cavations Check the suction head and lower the position of the pump Output of water is too large Decrease the speed of engine Inlet hose is obstructed by foreign matter so the resistance is too large Check the inlet hose and strainer basket and ...

Отзывы: