CONNECTING ELECTRICAL LOADS

Attempting to connect generator directly to the electrical system of any building
structure.

Back feeding electricity through a building’s electrical system to the outside utility feed lines
could endanger repair persons attempting to restore service. Failure to use a double throw
transfer switch when connecting to a structure's electrical system can damage appliances and
WILL VOID the manufacturer's warranty. Never backfeed electricity through a structure's
electrical system. 
To connect to a structure's electrical system in a safe manner, always have a Double-Throw
Transfer Switch installed by a qualified electrician and in compliance with local ordinances.
(When installing a Double-Throw Transfer Switch, a minimum of 10 gauge wiring must be
used).

IMPROPER CONNECTION OF ITEMS TO GENERATOR

Exceeding the load capacity of the generator by attaching too many items, or items with very
high load ratings to it could result in overheating of some items or their attachment wiring
resulting in fire or electrical shock. Make sure that the sum total of electrical loads for all attachments does not exceed the load rating of the
generator.

WARNING! Failure to connect and operate equipment in the sequence below can cause damage to equipment and will void the
warranty on your generator.

1) Let engine run and warm up for five minutes after starting with no electrical load. Connect loads in the following manner to prevent damage

to equipment:

2) Connect “inductive” load equipment first, inductive loads consist of refrigerators, freezers, water pumps, air conditioners, or small hand tools.

Connect the items that require the most wattage first. 

3) Connect the lights next.
4) Voltage sensitive equipment should be the last equipment connected to the generator. Plug voltage sensitive appliances such at TV's, VCR's,

microwaves, ovens, computers, and cordless telephones into a UL/CSA listed voltage surge protector, then connect the UL/CSA listed
voltage surge protector to the generator.

Overloading the generator will cause power fluctuations and can damage equipment and appliances.

King Canada will not be responsible for equipment damaged as a result of voltage surges, improper operation or improper
installation of the generator.

120V AC DUPLEX RECEPTACLES

For normal 120V operation, plug your appliance or power bar into one of the duplex
120V receptacles (A) Fig.8. 

12V DC RECEPTACLE (Fig.8) -Main use, charging automotive batteries

IMPORTANT: Allow generator to run at no load for 5 minutes upon each initial
start-up to allow engine to stabilize.

To charge battery:
1) Using the supplied battery cables, connect the red positive (+) battery cable to the

battery's positive (+) terminal.

2) Connect the black negative (-) battery cable to the battery's negative (-) terminal.
3) Insert the plug end of the DC cable in the specially designed DC receptacle (B) Fig.8.
4) Charge the battery according to battery or equipment manufacturer recommen-

dations.

To operate 12V DC equipment:

1. Refer to the 12V DC equipment owner's manual for operation of equipment and any special cable or adapter requirements.

ELECTRICAL CONNECTIONS 

Figure 7

Figure 8

Содержание 1500W Gasoline Generator KCG-1500G

Страница 1: ...CTION MANUAL COPYRIGHT 2007 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL KCG 1500G Read this manual Do not attempt to operate this generator until you have read and understood the safety operati...

Страница 2: ...ability caused by shipping improper handling improper installation improper maintenance improper modification or the use of accessories and or attachments not specifically recommended Repairs necessar...

Страница 3: ...ock will occur Be sure to ground earth the generator ELECTRICAL CONNECTION NOTES Avoid connecting the generator to commercial power outlet Avoid connecting the generator in parallel with any other gen...

Страница 4: ...mbient such as storage rooms or garages can interfere with its proper ventilation features causing overheating and possible ignition of the materials or buildings Operate generator in a clean dry well...

Страница 5: ...fore pulling recoil starter 14 Power indicator light When the switch has been turned on and the recoil starter has been pulled to start engine the power indicator light will come on 15 Low oil warning...

Страница 6: ...e fuel tank before operating 1 Check the fuel level indicator window A Fig 2 if the orange float gauge is all the way up it is not necessary to add fuel If you do not see or hardly see the orange floa...

Страница 7: ...t to the ON position 3 Move the choke control lever B located above the air filter to the Choke position NOTE No choke is required on warm engines Make sure choke lever is in the Run position on warm...

Страница 8: ...pment 2 Connect inductive load equipment first inductive loads consist of refrigerators freezers water pumps air conditioners or small hand tools Connect the items that require the most wattage first...

Страница 9: ...tage generator 2500 maximum starting wattage Wattage Requirement Chart below This is only a guideline each appliance or electrical device needs to be checked for its specific operating load DETERMININ...

Страница 10: ...Filter Maintenance 1 Set the fuel shut off valve to the OFF position and dismantle the fuel cock assembly A Fig 12 from the fuel tank by undoing the fuel cock hex nut B with an open ended key 2 Slide...

Страница 11: ...ntilation 1 Faulty rectifier 2 Faulty windings in field coil 3 Faulty wire harness CORRECTION 1 Add fuel or oil 2 Turn to ON position 3 Replace spark plug 4 Adjust choke accordingly 5 Open fuel shut o...